ML20154R329

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Gauging Source for Model Tp. Certificate:NR-300-S-859-S
ML20154R329
Person / Time
Issue date: 10/21/1998
From: Baggett M, John Lubinski
NRC
To:
Shared Package
ML20154R332 List:
References
SSD, NUDOCS 9810260296
Download: ML20154R329 (6)


Text

_ - _ - _ _ _ -

li REGISTRY'OF RADIOACTIVE SEALED SOURCES AND DEVICES L

-SAFETY EVALUATION OF SEALED SOURCE OCT 21 1998 PAGE 1 OF 3

. NO.~ : NR-300-S-859-S DATE:

l-SEALED SOURCE TYPE: Gauging, Source' MODEL':

.TP l

MANUFACTURER / DISTRIBUTOR:

Gammai Indust ries, Inc.

P.O. Box 2543 Baton Rouge-LA 70821 s

4 f

-i ISOTOPE:

' MAXIMUM ACTIVITY:

' Iridium-192-200 Ci (7.4 TBq)

LEAK TEST FREQUENCY:

'6 Months-PRINCIPAL USE:

(A) Industrial Radiography

. CUSTOM SOURCE:

YES X

NO l:

9810260296 981021 PDR RC e

+

t SSD PDR j'

~.

-. ~. - -. -.. - -

. ~ ~ -.. -. -. -.....,

Y i

REGISTRY 0F' RADIOACTIVE' SEALED SOURCES AND DEVICES RSAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-859-S

-DATE:

2 1 1998 PAGE 2 OF.3 c

SEALED SOURCE TYPE: Gauging' Source' DESCRIPTION:

The-Model TP source' capsule is designed for use in the Technical Operations Model 616 Air Operated'Pipeliner Exposure device.

The radioactive material is singly encapsulated in 304 or 316.

stainless ~ steel using a heltarc:(TIG)' welding technique.

PROTOTYPE TESTING:

This source has-a classification of E32212 as described in ANSI publication N5.10-1968. The manufacturer states that prototype

-sources have met the test criteria specified in the ANSI document.

QUALITY ASSURANCE AND CONTROL:

Each source is visuallyLinspected after fabrication, then subjected;to a contamination: wipe leak test.

If'the wipe test indicates-contamination, then a hot water bubble test will be 1

performed.

i LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:

1

.i

.:The device shall be possessed and used by persons.

specificallyElicensed'by the NRC or.an Agreement State.

,s

,. Handling, storage,"use, transfer, and disposal:

To be determined by-the~ licensing authority.

'eiThis registration sheet and the information contained within p

the references'shall.not be changed without the written consent of the NRd.

l-4 Y

~

l.

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES L

SAFETY. EVALUATION OF SEALED SOURCE I

JNO.: NR-300-S-859-S DATE:

2 I l998 PAGE 3 OF 3 p-l' SEALED SOURCE TYPE: Gauging Source SAFETY ANALYSIS

SUMMARY

The Model.TP source is no~ longer manufactured or distr.ibuted by Gamma Industries, Inc. and Gamma. Industries, Inc. is no longer in

' business.

Therefore, the registration certificate is being

-converted to anlinactive registration certificate.

[

The-source:was originally approved.for licensing purposes by the

!~

Louisiana Division;of Radiation Control.

NRC attempted to obtain copies of all information submitted.by the registrant in support of the evaluation.

However,'NRC could not locate all the

'information.

Therefore, no safety evaluation of the source was performed as.part of the conversion of the certificate to inactive' status.

l l-

-ISSUING AGENCY:

U.S. Nuclear Regulatory Commission

,/,

1 1988 Date:

Reviewer:

/

/T

~

/JohnW. Lubinski Date:

Concurrence: DGZA/vem Michele'L. Burgdss L

y r,

i PASE1 NRC FORM 567 U. S. NUCLEAR REGULATORY COMMISSION (e 83)

REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION jf----

INSTRUCTIONS: Send tNo request AND a copy of all reisted letters /apphcahone and dnrMngs to: The Seeled Source Safety Section, ATTN: CNef, OWFN Mail Stop 6 H3. Change the Ucense Tracidtsg System rnilestone to 19 and seeign to rev6 ewer code I-5.

NOTE: Retah a copy of tNo request with the application and background files.

R STER REGION / LOCATION:

TELEPHONE NUMBER DATE ~

f/p q l

ll lli IV V R HQ C LFDCB

  • y O p')W& _

r7 M TYPE OF ACTION REQUESTED (Check as appropriate)

)

APPUCANTS NAME SOURCE REVIEW AMENDMENT OF REGISTRATION SHEET N B R(S)

MAL CONTROL NUMBER (S)

DEVICE REVIEW LETTER /AS PUCATION DATE UCENSE NUMeER(S)

CUSTOM REVIEW

-h b--

3--S

$ 77?r?? a. D d u S h / e S i M-j P.O. Box sy3 h1'on ooge, G9 90&p/

v FOR 8888 USE ONLY REVIEWER MODEL S

NO

_ /~ $lrYk2r llldk' NUMBER AS$10NEo$5$

onTEReCovEo/ /

04fE AssioNeo

/

oATu To rEEs 5/R/98 T-//-98 TYPE OF ACTION Onecate me nur:6er of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (98)

NEW NEW NEW NEW AMENDMENT AMENDMENT AMENDMENT AMENDMENT

_j NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Speedy)

TOTAL NUMBER OF NOTES

g Ma_/(e Ce/~N[/ca/e u B R OF jghf yd, DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY j NEW REGISTRATION -

_j PRODUCT INACTIVE -

g/

NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILUNG FOR FEE USE ONLY TYPE OF FEE -

FEE CATEGORY 90 90 K_ MWNd\\

]9A 98 AMOUNT ~ ~ r j

CHECK NUMBER MATANN UPDATED

~ AS REQUIRED

$ +S' J MATSYS UPDATED DATE OF CHECK LOG pht h b, AS REQUIRED My g4A dl'il APPR Eo.,

-TE -N L

COMMem t

NRC FORM $67 (443).

1 1

f-i b

REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.:.

LA300D143S DATE:

November 13,-1981 PAGE 1 0F 6 CEVICE TYPE:

Control Device For X-Ray Crawlers MODEL: Master Minder Model' 2 MANUFACTURER / DISTRIBUTOR:

Gamma Industries, Inc.

P.O. Box 2543 Baton Rouge, LA 70821 MANUFACTURER / DISTRIBUTOR:

SEALED SOURCE MODEL DESIGNATION:

Gamma Ind. VD(HP)

- {--

ISOTOPE: Cesium-137 MAXIMUM ACTIVITY:

225 mil 11 curies Depleted Uranium Shielding, 7.7 kilograms LEAK TEST FREQUENCY:

PRINCIPAL USE:

Industrial Radiography CUSTOM DEVICE:

YES X N0 bb

.