_
ia
(,-
t lJ L REGISTRY'OF RADIOACTIVE' SEALED SOURCES.AND DEVICES s
SAFETY. EVALUATION OF SEALED SOURCE l..
I NO.: NR-300-S-8'57-S
.DATE: - OCT 21 1998 PAGE 1 OF 3 SEALED SOURCE TYPE:. Radiography Source MODEL:
NPX Gamma Industries,.
s MANUFACTURER / DISTRIBUTOR:
p.l 7
Inc.
P.O Box 2543 l
i
. Baton. Rouge, LA 70821.
1 4
l i
l i
ISOTOPE:
MAXIMUM ACTIVITY:
I Iridium-192 200~Ci (7.4 TBq) l LEAK TEST FREQUENCY:
6 Months
' PRINCIPAL USE:
(A) Industrial Radiography I 'i +
t i
P
- CUSTOM SOURCE:
'JES X
NO I
/
4 f:
- 9810260275 981021 PDR RC c
BSD PDR V~
l0 (VJoy+ s >
.REGISTRYf0F RADIOACTIVE SEALED' SOURCES AND DEVICES SAFETY EVALUATION.0F SEALED SOURCE 4
NO.:-NR-300-S-857,-S, DATE: l C 1 1 19981 PAGE 2 OF 3 SEALED SOURCE-TYPE 1 Radiography' Source DESCRIPTION:
The NPX' source capsule-made by Gamma Industries is identical'inL overall dimensions and threads to the C-164 (SRC-3) model source manufactured by Atomic-Energy of Canada Limited.
This source may be used in the Noram Testing Technology Limited devices, Model Pan X-I',
Pan X-II, SE-I (a source ex' cnger) and RCC-10 la remote o
control camera).
This source-may e be used as a replacement l
source in any device which uses the AECI C-164 (SRC-3) source
~
capsule.
This source capsule is equivalent to the old-Gamma j
- Industries Model S-27 source capsule.
9 PROTOTYPE TESTING:
This-source-has a classification of E32212, as described in ANSI publication N5.10-1968. The manufacturer states that prototype
. sources have met the test criteria specified in the ANSI document.
QUALITY ASSURANCE AND CONTROL:
Each source is visually inspected after fabrication, then j
subjected to'a contamination wipe leak test.
If the wipe test Lindicates contamination, then a hot water bubble test will be performed.
LIMITATIONS AND/On OTHER CONSIDERATIONS OF USE:
-The' device shall be possessed and used by persons specifically licensed Int the NRC or an Agreement State.
- Handling,: storage, use,. transfer, and disposal:
To be determined by the licensing authority.
. This registration sheet and the information contained within the references shall not be changed without the writ';en consent of the NRC.
i
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-857-S DATE:
CT 21 1998 PAGE 3 OF 3 SEALED COURCE TYPE: Radiography Source SAFETY ANALYSIS
SUMMARY
The Model NPX source is no longer manufactured or distributed by Gamma Industries, Inc. and Gamma Industries, Inc. is no longer in business.
Therefore, the registration certificate is being converted to an inactive registration certificate.
The source was originally approved for licensing purposes by the Louisiana Division of Radiation Control.
NRC attempted to obtain copies of all information submitted by the registrant in support of the evaluation.
However, NRC could not locate all the information.
Therefore, no safety evaluation of the source was performed as part of the conversion of the certificate to inactive status, t
ISSUING AGENCY:
U.S.
Nuclear Regulatory Commission
,r, OCT 21 jgga
~
~
Reviewer:
Date:
'okn W.
Lubinski Date:
Concurrence:
WWU3.[M%,
Michele L-Burge'ss