ML20154Q879
| ML20154Q879 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island |
| Issue date: | 09/26/1988 |
| From: | Musolf D NORTHERN STATES POWER CO. |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| Shared Package | |
| ML20154Q884 | List: |
| References | |
| NUDOCS 8810040093 | |
| Download: ML20154Q879 (1) | |
Text
.
Mr Northern States Power Company 414 Nicoitet Man Minneapohs Minnesota 55401 Te' phone l612) 330-5500 e
September 26, 1988 Director of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Attn: Docucent Control Desk k'a shingt on,
DC 20555 PPAIRIE IS1AND NUCLEAR GENERATING PIANT Docket Nos. 50 282 License Nos. DPR 42 50 306 DPR 60 Generic Criteria For Justification Of Continued Operation on September 21, 1988, the NRC Staff met with NSP representatives at Prairie Island to discuss generic criteria to be utilized for the justification of continued operation when major discrepancies in "as-built" safety related riping are encountered. Attached is a copy of the generic criteria agreed to during the meeting.
Please contact us if you have any questions regarding the information provided.
N David Musolf Manager Nuclear Support Services c: Regional Administrator-III, NRC NRR Project Manager, NRC Senior Resident Inspector, NRC G Charnoff Attachwant:
Criteria For Determining Justification For Continued Operation k' hen Encountering Major Dis.crepancies in "As Built" Safety Related Piping, September 21, 1988 0\\
O setoo40003 880926 DR ADOCK 050 8,
\\