ML20154Q867
| ML20154Q867 | |
| Person / Time | |
|---|---|
| Site: | Framatome ANP Richland |
| Issue date: | 03/13/1986 |
| From: | Nelson G, Schuster M NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | |
| Shared Package | |
| ML19277J324 | List: |
| References | |
| 70-1257-86-01, 70-1257-86-1, NUDOCS 8603240148 | |
| Download: ML20154Q867 (1) | |
Text
_
v The information on this page is considered to be appropriate-for public disclosure pursuant to 10 CFR 2.790 U. S. NUCLEAR REGULATORY COMMISSION REGION'V-Report No.
70-1257/86-01 (IE-V-731)
Dockit No.
70-1257 Lic;nse No.
SNM-1227 Safeguards Group:
III Licensee:
Exxon Nuclear Company, Inc.
2101 Horn Rapids Road
^
Richland,. Washington 99352 Facility Name:
Exx'on' Nuclear Fuel Fabrication Facility
~
Inspection at:
Horn Rapids' Road, Fadilit. Richlandi Washington Inspection conducted:
February 10 through 14 and 25,<1986-Date of Last Material Control and Accouni.ing Inspectiont 3 December 3 through 6; and December 9 a'nd 20,1985 Type of Inspection:
- Routine and React!ive U announced Material Control
^
and Accounting Inspector:
[" M "
jG. B. Nelson, Chemist Date Signed
@/) O AAA" s //sh4-i Approved By:
1 M. D. Schuster, Chief _
Dat'e Signed Safeguards Section 4
I Inspection Summary:
Areas Inspected: Facility organization and management controls, measurement systems, measurement control and statistics, material" control and accounting for imports and exports and follow-up on violations._ Inspection procedures 85203, 85207, 85209, 85301 and 92702 were covered.
Results: ~ Within 't!he areas inspected,.no violations or deviations were identified.
8603240148 860317 PDR ADOCK 07001257 C
PDR y.
aA.-
-