NOTICE OF NONCONFORMANCE Valcor Engineering Corporation
- Docket 99900728 Springfield, New Jersey Based on the results of an inspection conducted on September 8-11, and October 2,1998, it appears that certain of the Valcor Engineering Corporation (Valcor) activities were not conducted in accordance with NRC requirements.
Criterion V, " Instructions, Procedures, and Drawings," of 10 CFR Part 50, Apper. dix B requires that activities affecting quality be prescribed by documented instructions and procedures and shall be accomplished in accordance with those instructions and procedures.
Contrary to Criterion V, Va!cor failed to prescribe written guidance within its procedures and associated drawings to control the application of Acheson Colloids Company (Acheson) dry film graphite lubricant (Dag@ 156) on its V70900-65-11 series solenoid operated valves.
Additionally, Valcor failed to address a Dag@ 156 tec:- ' cal information sheet note that expressed a five minute drying time caution before assembling components. (Nonconformance 99900728/98-01-01)
During the October 2,1998, portion of the inspection, the inspectors reviewed your corrective actions and steps taken to preclude recurrence and found thern acceptable. Therefore, no further response to the NON is required.