ML20154Q187

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 880427-29 & 0503.Violation Noted:Failure to Maintain Records Showing Result of Radiological Surveys
ML20154Q187
Person / Time
Site: Saxton File:GPU Nuclear icon.png
Issue date: 05/27/1988
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20154Q182 List:
References
50-146-88-01, 50-146-88-1, NUDOCS 8806060211
Download: ML20154Q187 (1)


Text

- _ _ _ _ _

o

' APPENDIX A

_NOTICE OF VIOLATION l

Saxton Nuclear Experimental Corporation (SNEC) Decket No. 50-146 l 1 Upper Pond Road License No. DPR-4 l Parsippany, New Jersey 07054 l

l and in As a result of the inspection conducted on A ril 27-29 and May 3},1988,following accordancewiththeNRCEnforcementPolicy($0CFR2,AppendixC the violation was identified:

l 10 CFR 20.201, "Surveys," requires, in part, in paragraph shall make or cause to be made such surveys as are reasonab(b) le under thethat each licensee

' circumstances to evaluate the extent of radiation hazards that ir.sy be present.

10 CFR 20.401, "Records of surveys, radiation monitoring, and disposal,"

requires, in part, that each licensee shall maintain records showing the results of surveys required by 10 CFR 20.201(b).

Contrary the the above, on or about March 31, 1988, the licensee performed a contamination survey on a large pipe prior to its release for unrestricted use.

No records were maintained showing the results of the performed radiological surveys.

This is a Severity Level IV violation (Supplement IV)

Pursuant to the provisions of 10 CFR 2.201, Saxton Nuclear Experimental Corporation is hereby required to submit to this office within thirty days of the date of the letter which transmitted this Notice, a written statement or explanation in reply, including: (1) the corrective steps which have been taken and the results achieved; (2) corrective steps which will be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Where good cause is shown, consideration will be given to extending this response time.

)

'. tU k O. II 8806060211. 880527.

POR ADOCK 050CW46.

Q DCD

- - - ______________