ML20154P913

From kanterella
Jump to navigation Jump to search
Requests Listed Addl Info Re 851219 Application for License, Including Procedures for Disposal of Foil,Cleaning Detector Cells & Ni-63 Foil Leak Testing
ML20154P913
Person / Time
Issue date: 01/28/1986
From: Whiston P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Potter S
GRAY LABORATORIES INC.
Shared Package
ML20154P887 List:
References
80343, NUDOCS 8603200453
Download: ML20154P913 (2)


Text

-

Y JAN 2 8 1986 Gray Laboratories, Inc.

ATTN: S. P. Potter President 1005 East 5th Street Kansas City, M0 64106 Re: Application dated December 19, 1985 for an NRC License Gentlemen:

Certain items of your application are not in sufficient detail to enable us to complete our review. Therefore, it will necessary for you to respond to the following items:

1. Describe your procedures for:
a. Disposal of the foil when its use has been discontinued. If this disposal is by return to the manufacturer, please so state.
b. Cleaning detector cells and/or removal and exchange of detector cell foil. If you follow the manufacturer's recommended procedures, please provide a copy of the procedures. If detector cells are returned to your supplier for cleaning of detector cells and/or removal and exchange of foil, please specify this.
c. Leak testing the nickel-63 foil. If you will use a comercial leak test kit, please provide the name of the supplier and model number of the kit. If you will conduct your own leak tests, please provide descriptions of the following:

(1) The materials and procedures used for collecting leak test samples.

(2) The name of the manufacturer and model number of the measuring instrument used to analyze leak test samples.

(3) Your procedures for calibration of the measuring instrument including a sample' calculation showing how leak test results are converted to microcuries.

2. Submit the name(s) of the employee (s) (other than yourself) who may use/ supervise the use of the gas chromatograph, including the name of the individual designated as the radiation safety officer.

8603200453 e60318 REG 3 LIC30 PDR

s .

Gray Laboratories, Inc. 2

3. Specify the number of sources / detector cells you wish to possess.

It may be helpful for you to refer to the enclosed " Guide for Preparation of Applications for the Use of Sealed Sources in Gas Chromatography Devices" when completing your response to this letter.

We will continue our review of your application upon receipt of this information.

Please reply in duplicate, within 30 days, and refer to Control Number 80343.

Sincerely, Original Signed By Patricia J. Whiston Materials Licensing Section

Enclosures:

As stated l

RI

/cm

/ /86