r :.
I
[-
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES
[
SAFETY EVALUATION OF SEALED SOURCE (CORRECTED PAGE 1-SEPTEMBER 09, 1998) l NO.: NR930S802U DATE:
-May 19, 1964 PAGE 1 OF 2 SEALED SOURCE TYPE:
Density Moisture Meter Source MODEL: AM-CS-1 MANUFACTURER / DISTRIBUTOR:
NUMEC Subsidiary of Babcock-Wilcox Warren Avenue Apollo, PA 15613 MANUFACTURER / DISTRIBUTOR:
ISOTOPE:
Cesium-137 MAXIMUM ACTIVITY: 30 mci (370 MBq)
Americium-241 33 mci (1.222 GBq)
LEAK TEST FREOUENCY PRINCIPAL USE:
Portable. Moisture Density Gauges CUSTOM SOURCE:
YES X
N0 f
1 i
9810200243 981019 PDR RC SSD PDR 9fuozoo tf3 lll
. _ _ =..
i l
- j t
REGISTRY'OF; RADIOACTIVE' SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE i
HQ 1 NR930S802U DATE: May 19,.1964 PAGE 2 OF 2
{
m i
SEALRn SOURCE TYPE:
Density Moisture' Meter Source
'i l
DESCRIPTION:
The source consists of two stainless steel capsules, one inside of the other, both' sealed by heliarc welds.
The source is cylindrical in shape with outside dimensions of 0.31 inches (7.9~mm) diameter _and.0.5 inches (12.7.nn) length.
i I
The inner capsule is divided into two chambers, one containing
)
the cesium 137 in the form of a deposit of Cesium Chloride powder-
)
and the other containing the'Ame'ricium 241 in the form of
-americium oxide powder.
LABELING:
The' source-is not labeled since it is designed for use-in the Model 8200 device source holder which is. labeled as described in the' device sheet for'the Model 8200 Density Moisture Meter Probe Assembly.
ISSUING AGENCY:
U.S. Atomic Energy Commission l
i I
'f r
I i
I r