ML20154H971

From kanterella
Jump to navigation Jump to search
Forwards non-proprietary & Proprietary Rev 0 to Psat 05656A.04, Calculation of TMI-1 ESF Component Leakage Iodine Release. Proprietary Calculation Withheld (Ref 10CFR2.790(a)(4))
ML20154H971
Person / Time
Site: Crane 
Issue date: 10/06/1998
From: Langenbach J
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20138L274 List:
References
1920-98-20561, NUDOCS 9810150125
Download: ML20154H971 (2)


Text

\\GPU

r;:

NUCLEAR Post Office Box 480 Middletown, PA 17057-0480 Tel 717 944-7621

{

l 1

I October- 06,1998 l

1920-98-20561 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555

Dear Sir:

Subject:

Three Mile Island Nuclear Station, Unit 1, (TMI-1)

Operating License No. DPR-50 Docket No. 50-289

)

Submittal of Proprietary Polestar Report REF.:

Control Room Habitability Evaluation, dated March 24,1998 i

By request of the Project Manager, the enclosed calculation is being transmitted to the NRC for the purpose of aidirig the Staffin its technical review of the Control Room habitability. This calculation supports a substantive reduction in the CR dose consequences previously transmitted by GPU Nuclear Inc. letter dated March 24,1998 referenced above (Letter No. 1920-98-20145). The calculation will also support a future Technical Specification Change Request for an increase in the Accident Recirculation Systems Leakage rates and related dose consequence analyses performed for the Maximum Hypothetical Accident.

The enclosed POLESTAR Calculaticm PSAT 05656A.04, Rev. O, " Calculation of TMI-l

(

Engineered Safety Feature Component Leakage Iodine Release" contains proprietary

\\

information as defined in 10 CFR 2.790(a)(4). Accordingly, it is requested that this document be withheld from public disclosure. An affidavit certifying the basis for this application for withholding as required by 10 CFR 2.790(bX1) is also enclosed with this letter, along with a non-proprietary version of the report.

\\

b C l.

u e a< t

,eioiso12,,eiou PDR ADOCK 05000289 e

e-4 gm i

m

_~

1 U.S. Nuclear Regulatory Commission 1920-98-20561

- Page 2 -

If you have any questions or need additional information please contact our Mr. Gregory M. Gurican of the TMI Nuclear Safety & Licensing group at (717) 948-8753.

Sincerely, b

L ames W. Langenb i

Vice President and Director, TMI JWIlgmg File: 98159

Enclosures:

(1) Proprietary POLESTAR Calculation No. PSAT 05656A.04, Rev. O,

" Calculation of TMI-1 Engineered Safety Feature Component Leakage Iodine Release."

(2) Non-Proprietary POLESTAR Calculation No. PSAT 05656A.04, Rev. O, " Calculation of TMI-l Engineered Safety Feature Component Leakage Iodine Release."

'(3) Polestar Applied Technology,Inc. AFFIDAVIT Certifying Request for Withholding from Public Disclosure cc:

Administrator Region I TMI Senior Resident Inspector TMI Senior Project Manager 1

l