JOSEPH M. FARLEY NUCLEAR PLANT UNIT 2 NARRATIVE StkHARY OF OPHtATIONS August, 1988 h re were no unit shutdowns or significant power reductions during the month of August.
- N following major safety-related maintenance was perfonned in the month of August:
1.
h low pressure pumping element was replaced in the 2D service water air compressor.
2.
h trim was replaced in charging flow control valve FUV-122.
3.
A design change was perfonned to correct a flow problem in radiation monitors R-11 and R-12.
4.
A burned coil was replaced in the 2B air ccepressor breaker closing coil.
5.
h 2B charging punp room cooler was cleaned and its carbon steel atuds were replaced with stainless steel studs.
o 6.
Miscellaneous corrective and preventive maintenance was perforwed on l
the diesel generators.
i i
4 J
N P
1 l
l l
4 j
CCQ h i
- 4
/
8809220051 880831 PDR ADOCK 03000364 R
PDC l
i
OPERATING DATA REPORT l
i DOCKEF No. 50-364 DATE V 788 00MPIRITD BY D. N. More
'IELEPtKNE (205)89F5
, OPERATING S'IWItJS Notes
- 1. Unit Name
.70seph M. Farley - Unit 2
- 2. Reporting Period:
August, 1988
- 1) Cumulative data since
- 3. Licensed %ermal Power (Mt):
2,652 7-30-81, date of
- 4. Nameplate Rating (Gross We):
860' comercial operation
- 5. Design Electrical Rating (Net We); 829
- 6. Maximum Dependable Capacity (Gross Wo):
863.8
- 7. Maximum Dependable Capacity (Net We):
822.8
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons: N/A
- 9. Power Level To Which Restricted, If Any (Not MWe):
N/A
- 10. Reasons For Restrictions, If Any:
N/A his Month Yr-to-Date Cumulative
- 11. Itours In Reporting Period 744 5,855 62,160
- 12. Number Of Hours Reactor Was Critical 744.0 5,855.0 58,748.9
- 13. Reactor Reserve Shutdown Hours 0.0 0.0 138.0
- 15. Unit Reserve Shutdeun Hours
~
7T4.0 5,655 7 -
53,103.5-
- 14. Hours Generator On-Line 0. 0-3T DT i
- 16. Gross % ermal Energy Generated (MWH)
I 373 UB3 153ET,TD 1TB25"235-
- 17. Gross Electrical Energy G0nerated (WH) 641,438 5,165324 44,308,240
~~
- 18. Net Electrical Energy Cenerated (WH)
~610,898 4,866,028 42,017,766 t
- 19. Unit Service Factor 100.0 100 7 35T
- 20. Unit Availability Factor 100.0 TOU T 85 7
- 21. Unit Capacity Factor (Using MDC Not) 99.8 '
101.0~
82.8
- 22. Unit Capacity Factor (Using DER Net) 99.0,
100.3 81.5
- 23. Unit Forced Outage Rate 0.0 0.0 4.8 j
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Durition oE~EichT:
N/A
- 25. If Shut Down At End Of Report Period, Estimated Date of Startup N/A
- 26. Units In Test Status (Prior to Commercial Operetion):
Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81 INITIAL ELECIRICITr D572&BI 05/25751 C0f9tERCIAL OPERATION 0070r781 U7710/81 l
l 1
l
{
Form 2/30
DOCKET No.
50-364 UNIT 2
DATE SEPTEMBER 1, 1988 t
COMPLETED BY D. N. Morey TELEPHONE (205)899-5156 MON 1H August 1
DAY ANERAGEDAILYPOWERLEVEL DAY AVERAGE DAILY POWER LEVEL (PWe-Net)
(PMe-Net) 1 821 17 821 2
822 18 822 3
821 19 920 t
4 822 20 820 a
l 5
822 21 820 6
820 22 821 7
819 23 820 8
820 24 821 9
821 25 824 10 820 26 825 11 820 27 822 12 819 28 824 23 820 29 821
~
i 14 822 30 821 1
15 820 31 822 l
16 823 l
INS 1 RUCTIONS on this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compate to the nearest whole megawatt.
Form 13/21
e c
UNIT SHthTAMS ACO PCwE2 RELUCTIONS DOCKER NO.
50-3'24 UNIT NAttE
.7.
M.
FARI.Z7 - UNIT 2 DATE SEP* EMBER 1, 1988 E
COMPLETED Br D.
3.
MORET REPOR* MONTH AUGUsr rELEPHOKE (2051899-5156 l
l l
l l
l METHOL Or l LICLESEE l l
l CAUSE E CORRECTIVE I
I.
I I
I i ccmATIo= 1 i Su=TIsc I eve =r I surEn I Comic =E=r i
ACrIos to I
i j
i=o.
I care 1:TrE I. uwn.
I aEAso=2 l wws mEAC:ca I mEvoer. I CocE' I cecE I
rmEvEur mECUxmE=cI I
L 2
5 I
I I
1 I
I I
I i
l I
! = ImE wI E :o U::: ss=rac: om sIG=IrIC2=r rowEm mEzUCrIoxs sUaI=G rat Mon:n or AUGUsr.
I I
I i
l I
i I
1 i
i i
f I
i i
i l
i I
I I
l~
l I
1 1
I i
i i
i l
i i
i I
I I
i l
I i
i i
i i
I i
l I
I I
I I
i l
i I
I I
I i
i I
I I
I I
I I
I i
i i
i l
I i
l I
1 I
I I
I I
i l
1 1
I I
I i
i l
I i
i I
i i
l i
I I
I i
l i
i l
i I
i l
1 i
i l
I i
1 l
i i
i l
i l
I I
i 1
i i
i 1
1 1
I I
I I
I I
I i
1 l
l 1
i I
I I
l I
I I
i i
l l
I I
i i
1 I
i i
i i
l I
i I
i i
1 1
1 I
I r: Forced Reason:
Method:
Exhibit G-Instructions s: s<heduled A-Equipment railure (Emplain 1-Manual for Preparation of Data j
B-Maintenance er Test 2-Marual scram.
Entry Sheets for Licensee C-Refuelta; 3-Automatic scram.
Event Report (LER) File (EUREG-E-Pegulator-Restriction 4-Other (Explain) 0161)
E-Operator Training & License Examination i
T-Administrat1*.
Exhibit I -Sames Source G-operational Error (Emplaint (9/77)
N-0ther tEmpiein>
l HDI Rxm L'2 l
F r
g,.
(,,
Alabama Power Company 600 North 18th Street Post offee Box 2641 Birmingham, Alabama 352914400 Telephone 20$ 2501837 W. G. Hairston,lH SeniorWe President Nuclear operatons i-
.a.labama Power
- h. whemektticsystem Septembe 12, 1988 Cocket No. 50-364 U. S. Nuclear Regulatory Commission ATIN: Document Control Desk Washington, D. C.
20555 Joseph M. Farlef Nuclear Plant Unit 2 Monthly Operating Data Report Attached are two (2) copies of the August 1988 Monthly Operating Report for Joseph M. Farley Nuclear Plant Unit 2, required by Section 6.9.1.10 of the Technical Specifications.
If you have any questions, please advise.
Yours very truly, l}).
ll W. G. Hairston, III WGH/JGSimb/1.6 i
Attachments xc Dr. J. N. Grace J
I I
[ FAY t