ML20154G077

From kanterella
Jump to navigation Jump to search
Responds to 880420 Request for Addl Info Re NRC Bulletin 88-002 on Steam Generator Tubes.Submittal of Proposal for Enhanced Leak Monitoring Program Forthcoming,Following Evaluation of Radiation Monitor/Leak Rate Correlation Study
ML20154G077
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 05/13/1988
From: Trzyna G
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
IEB-88-002, IEB-88-2, NUDOCS 8805240209
Download: ML20154G077 (2)


Text

_ _ _ _ _ _ _ _ _ _

. C'N

  • Commonwealth Edison

/ One First National Plaza, Chicago, Ilhnois O "J Address Reply to: Post Offc] Box 767

\\q,/ Ohicago, Illinois 60690 - 0767 May 13, 1988 U.S. Nuclear Regulatory Commission Washington, DC. 20555 Attn: Document Control Desk s

subject: Zion Nuclear Power Station, Units 1 and 2 License Nos. DPR-39 and DPR-48 l

Additional Information - Bulletin No. 88-02 Steam Generator Tubes N_RC Docket Nos. 50-295 and 50-304 Gentlemen:

This letter confirms an April 20, 1988 conference call between NRR and CECO personnel regarding NRC Bulletin No. 88-02.

Our response to the two questions that were raised during that conversation are presented below:

(1)

Question: At what frequency would Zion continue to monitor steam generator leakage, once the leak has stabilized.

Response: Once a steam generator tube leak was determined to have stabilized, Zion would continue to sample at 4-hour intervals for at least the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

(2)

Question: How would Zion respond to steam generator tube leakage that is greater than equal to 200GFD?

Response

If the rate of increase is 25GPD or greater when leakage reaches 200 GFD, then Zion will inmediately begin a power reduction to less than 50'4 power within one hour.

The submittal of Zion's proposal for an enhanced leak monitoring program will be forthcoming, following the evaluation of the radiation monitor / leak rate correlation study.

I

\\

8805240209 880513 PDR ADOCK 05000295

{

Q DCD

/-

_ +

\\-

s*

e jW ps'

.s*/

- /

/

4 p**"

../

j Please direct any further questions regarding this matter,to this a"

s.F office.

s.. -

Very truly yours, A

Glenn E. Trsyna 7

Nuclear Licensing Administrator

i j

'/k1'j i

cc: Resident Inspector-Zion J. A. Norris-NRR l

4633K l

l

,