Text
. _ _ _ - _ _ _ _
U$VERSITY J'/
wUTAH r
/
./
/
./
/
[
August 25,1988
/
6 Jaraes M. Taylor Deputy Executive Director for Regional Operations U. S. Nuclear Regulatory Commhsion Washington, D. C. 20355
Dear Sir:
Pursuant to the telephone conversation between NRC Region IV and the Licensee on 23 August 1988 the following additional information is provided regarding the University of Utah's response, dated 4 August 1938, to Notice of Violation and Deviation, Report 50-407/88 07, 50-0723/88-01, University of Utah Reactors (License R 25: AGN 201, Docket 50 072 and License R 126: TRIGA, Docket 50-407).
Violation 2 (407/880102). In addition to the revised written procedure for insertion and I
removal of heavy water tanks, the Licensee has modified its checkout procedure for operation of the TRIGA reactor (see enclosed form NEL 001, Sheet 1) to require that the Maintenance Log be reviewed for any core operations which might affect reactivity. This action will ensure that the operator is apprised of such changes.
Violation 3 (407/880103). Any component removed from the reactor core which may be radioactive and is not to be immediately placed in a shielded container will be surveyed for contact radiation levels and will be tagged with the maximum radiation reading. The Facility Operations Manual will be revied by September 5,1988 to reflect this practice.
Further, the Radiation Saf:ty Officer has reviewed procedures to ensure that NEL staff are perfornung and documenting such radiation surveys in an acceptable manner.
Sincerely, pk j 4)
Dietrich K. Gehmlich Reactor Administrator cy: NRC Region IV 8809190252 880025 PDR ADOCK 05000072 O
PNV t e of the an 2202 Merrdi Engincenng Bwkhng Salt ta' e Oty, l'tah $4112 3
a Teleptm,3e 901) 5814911 t
Form NEL 001 Sheet 1 RSC Approval:5/25/88 B.1 TRIG A PRELIMINARY CIIECK SIIFET NO.
- DATE, OPERATOR
- 1. Door Closed:
(V)
Front door closed:
(V)
Rad Dose Log:
(V)
- 2. Visual inspection of reactor tank and area: _(V) Source & D O reflector in core: _ (V)*
2 Derraneralizer:
(on-off) Flow rate: _ gal / min Check and date Air Monitor: _(V)
Deactivate Security System: _(V)
Deactivate Radiation Alarm Damper:
(V) j
- 3. Auxiliary Survey Meter: Make Serial Number On _(V) i Console Power On:
(V)
Source Light On:
(V)
Recorder On:
(V)
Paper Checked and Dated:
(V)
Chart Speed Standby:
(V)
Review Maintenance Log for any core alterations since the last operation which may possibly affect core reactivity:
(V)
Record Checkout in Operations leg: _(V)
Log Number:
Ventilation System On:
(V)
Damper Lights Checked:
(V) off
- 4. Calibrate Radiation Monitor: _(V)
Background:
mR/hr lon Chamber Voltages LV21: _(14) LVx10:
(34) IIVx10:
(74)
Fuel Temperature TC#1:
'C TC#2:
'C TC#3:
'C I
Water Conductivity; pmho'em (< 5)
Water Temperature:
'C i
Compare Fuel and Water Temperatures:(NOTE AND REPORT ANY ANMIX 0US READINGS TO SRO)
Rods Down:
(V)
Shim Position:
Reg Position:
- 5. Reactor Room Pressurc.
1205 E/ outside, iwg(>.01) 1205 E/1205 D:
iwg(>.01)
Radiation Monitor Set Point Check:
TRIGA Tank:
Low:
(V) liigh:
(V)
Ceiling:
low:
(4) liigh:
(V)
Vent:
Low:
(V) liigh: _(4)
- 6. Recorder to Low Speed:
(V)
Recorder Pens Down: _(V)
Linear Power Switch to 1x100: _ (V)
Log Power Switch to 101: _(V) low leg Cal to "LO" (6x10-3 W)
Meter:
Red Pen:
(-10)
Low leg Cal to "Ill" (1x100 W)
Meter:
Red Pen:
(-50 80)
- 7. Key On:
(V)
LICENSED OPERATOR AND ONE OTiiER PERSON MUST BE PRESENT.
Additional Personnel:
- 8. Scram Reset:
(V)
WAIT 1 MINUTE BEFORE READING CURRENT.
Magnet Current Safety:.
(37)
Shim:
(33)
- 1f source or D O not in core inform R: actor Supervisor before startup.
2 ec/[t Date: May 25.1988 e to I a r:
,