Extends Invitation to Attend 880524 Meeting in Rockville,Md to Discuss Recent Tests of Hilti kwik-bolts.Attendees Requested to Present Brief Presentation of Subjs Listed on Encl Meeting Agenda
ML20154D591
Person / Time
Issue date: 05/06/1988
From: Berlinger C
Office of Nuclear Reactor Regulation
To: Jenny D
PCI
References
REF-PT21-88 NUDOCS 8805190254
Download: ML20154D591 (3)


Text

h,'

MAY 6 1988 j

Mr0 Daniel Jenny PCI 175 W. Jackson Blvd.

Suite 1859 Chicago, Illinois 60604 Gentlemen:

The Nuclear Regulatory Commission (NRC) was informed by Hilti Inc., in accor-dance with 10 07R Part 21, of recent tests of Hilti Kwik-Bolts that indicate that the previously recommended minimum edge distance from an anchor bolt to an unsupported concrete edge may be insufficient to develop 100% of the recom-mended anchor capacity.

The Hilti test results indicate that Hilti Kwik-Bolts placed at a distance of five anchor bolt diamet.ers from an unsupported edge, as reconinended by the Expansion Anchor Manufacturers Institute (EAMI) guidelines, have only 30% of the recommended anchor shear capacity and 78% of the recom-mended tensile capacity. Hilti further indicated, at a meeting with the NRC staff, that the test results are believed to be applicable to other expansion anchor bolts that use the same type of anchor mechanism as Hilti Kwik-Bolts.

The NRC staff feels that the test results indicating a 70% reduction in shear capacity are significant and indicate that there is a potential safety concern that will require further NRC review.

In view of the foregoing, the NRC would like to invite representatives of companies that supply bolts or provide bolt installation services to the nuclear industry, such as your company, to attend a meeting where pertinent information could be freely exchanged between meeting pa rticipa nts. The meeting is scheduled for May 24,1988, at 1:00 p.m. in Conference Room 12-B-11 at the NRC's White Flint Building which is located at 11555 Rockville Pike in Rockville, MD. We are requesting that attendees present a brief presentation, approximately 15 minutes, that addresses the subjects listed in the meeting agenda and any other aspects related to this issue which you consider important.

If you plan to attend, or if you have any questions or concerns (such as how to present proprietary information), please contact Jaine Guillen at i

(301) 492-1153 or Rom Lipinski at (301) 492-0844 before May 16, 1988.

Your cooperation on this matter would be greatly appreciated.

Sincerely.

Original Signed By Cd ll. Bukar OD190254 800506 Carl H. Berlinger, Chief R

PT21 EMVHyI Generic Communications Branch es Division of Operational Events Assessment Office of Nuclear Reactor Regulation

Enclosures:

1.

Meeting Agende 2.

Subjects of Presentations pj DISTRIBUTION w/ enclosures f)

CERossi, NRR CHBerlinger, NRR JGuillen, NRR gF EJButcher, NRR WDLanning, NRR RLipinski, NRR g) 1 PDR Central Files DCS I

00EA R/F OGCB R/F JGuillen R/F r

\\ _.

3EN m\\ Lew ul LM [v j

e B:0E3f:NRR C/0GCB:00EA:HRR 0GCB EXINRR JGu110n 05/L,/88 05/6/88- CHBerlinger RLipinski 05/l//88

~ MAY 6 13dB May 74, 1988 Meeting Agenda Item Speaker Time I. Introduction NRC 1:00 - 1:15 p.m. II. Presentations by A/Es 1:15 - 3:45 p.m. Architects / Engineers

  • III. Discussion / Forum Attendees 3:00 - 4:45 p.m.
  • Invited Architects / Engineers' Bechtel Power Corporation Brown & Root, Inc.

H. J. Degenkolb Ebasco Services, Inc. Gibbs & Hill, Inc. Gilbert / Commonwealth, Inc. Sargent & Lundy Engineers Stone & Webster Engineering Corp. Tennessee Valley Authority i URS/ John Blume Associates ) \\ l l i I v r =.. - - e--- 7 m-v--

1,yg 6.BBB Principal Subiects of presentations I. What was the "edge distance" as defined in the job specification in nuclear power facilities that you have designed and/or constructed? II. Identify the type of anchors to which the "five diameter" or other edge distance criteria applies (expansion anchors, cast-in-place anchors, or all). III. Discuss briefly the type of anchorage used for different types of safety-related equipment in nuclear power plants. IV. Describe the anchorage design methods used for nuclear power facilities. V. Describe any anchor tests conducted by your organization and indicate whether any reinforcement, either parallel or normal to the free edge, was present in the test samples. VI. Based on your experience, estimate the percentage of anchors installed in nuclear power facilities designed and/or constructed by your company that could be affected by the "edge distance" issue. l VII. Present your perspective of the "edge distance issue. d 1 9 y-r a 4 y-- 7--.. -g-4- ,w -w yn,}}