Amend 6 to License SNM-0205 for General Dynamics Corp, Revising Conditions 12 & 13 Re Possession & Use of Licensed Matl
ML20154C819
Person / Time
Site: 07000221
(SNM-0205-A-06, SNM-205-A-6)
Issue date: 12/31/1985
From: Glenn J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20154C823 List:
References
NUDOCS 8603050327
Download: ML20154C819 (1)


Text

. ________ _

i fC F m 374A R

M p

g I D

]

License number MATERIALS LICENSE Docket or aererence nuNr 1

SUPPLEMENTARY SHEET 1;.

070-00221 k]

Amendment No_ 06 1

"OTC Al RECORD COPY" General Dynamics Corporation y! Electric Boat Division

-]lGroton i

] Eastarn Point Road

}f In accordance with letter dated October

, Connecticut 06340 30, 1985, License Number SNM-205 is amended as j! follows:

l

]

i

']

Conditions 12. and 13. are amended to read:

']

l

-]

12 i

f

. Licensed material shall be used by, or under the supervision of, Eugene T. Reimer, Jr., D. R. Prentice, and individuals trained in accordance with the licensee's I

j procedures entitled " Calibration Facility Qualification Program," dated May 1983.

']

Each encapsulated plutonium source designed for the purpose of emitting neutron

] 13.

A.

or gamma radiation shall be tested for leakage at intervals not to exceed six (6) l 3

[

months.

In the absence of a certificate from a transfer indicating that a test i

has been made within six (6) months prior to the transfer, a sealed source l

3 received from another person shall not be put into use until tested.

I 1

-]

B.

The test shall be capable of detecting the presence of 0.005 microcurie of alpha !

]

contamination on the test sample. The test sample shall be taken from the sourcei f

or from appropriate accessible surfaces of the device in which the sealed source i j

is permanently or semipermanently mounted or stored.

Records of leak test j-results shall be kept in units of microcuries and maintained for inspection by 3

the Commission.

l 3

1 C.

If the test reveals the presence of 0.005 microcurie or more of removable alpha 3

contamination, the licensee shall immediately withdraw the sealed source from use j

and shall cause it to be decontaminated and repaired by a person appropriately 5

licensed to make such repairs or to be disposed of in accordance with the l

1 Commission regulations.

Within five (5) days after determining that any source I

1 nas leaked, the licensee shall file a report with the Material Licensing Branch, l'

]1 Division of Fuel Cycle and Material Safety, U. S. Nuclear Regulatory Commission, Washington, D. C. 20555, describing the source, the test results, the extent of i

y contamination, the apparent or suspected cause of source failure, and the L]

corrective action taken. A ccpy of the report shall be sent to the U. S. Nuclear!

1 Regulatory Commission, Region I, King of Prussia, Pennsylvania, 19406.

1

))

D.

Tests for leakage and/or contamination shall be performed by Eugene T. Reimer, Jr., D. R. Prentice, or by other other persons specifically authorized by the

)

Commission or an Agreement State to perform such services.

2a

!]

For the U.S. Nuclear Regulatory Commission

.]

1 Originni Signed Byt J&n F. relen l

]Date DEC 311985 By f

Nuclear Materials Safety and Safeguards Branch, Region I l

]l 8603o50327 051231 King of Prussia, Pennsylvania 19406 li REG 1 LIC70 PDR k(