Responds to NRC Bulletin 88-005,providing safety-related & nonsafety-related Applications List of West Jersey Mfg Co & Piping Supplies,Inc Matls
ML20154C267
Person / Time
Site: Farley  
Issue date: 09/07/1988
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
IEB-88-005, IEB-88-5, NUDOCS 8809140297
Download: ML20154C267 (4)


Text

.

t Alcbima Power Comp;ny 800 North 18th Street Post Off1ce Box 2641 Birmingham, Alabama 35291-0400 Te!ephone 205 2501837 W. G. Hairstsn, lin Sena Vice Pres' dent Nuclear Operations Alabama POWCf September 7. 1988 Docket Nos. 50-348 50-364 U.S. Nuclear Regulatory Commission A1TN: Document Control Desk Vashington, D.C.

20555 Gentlemen Joseph H. Farley Nuclear Plant - Units 1 and 2 Response to NRC Bulletin No. 88-05: Nonconforming Materials Supplied by Piping Supplies, Inc. (PSI) at Folsom, New Jersey and Vest Jersey Manufacturing Company (VJM) at Villiamstown, New Jersey NRC Bulletin No. 88-05 requested a report providing a list of VJM and PSI supplied materials installed or to be installed in safety-related systems found to not be in conformance with applicable code requirements or procurement specifications, identifying the applications in which the materials are used, the material specification, nature of component, size, pressure rating and chain of purchase.

In addition, confirmation of completion of specified actions for these safety-related materials and commensurate actions for non-safety-related materials was requested.

Supplement 1 to this bulletin added the requirement to include test results in the written report and reduced the scope from all VJM and PSI supplied "material" to just "flanges and fittings." Supplement 2 was then issued temporarily suspending most provisions of the bulleting hovever, the reporting of results, as of August 3, 1988, is still required.

As of August 3, 1988 Alabama Power Company had performed an extensive review of its procurement documentation for Certified Material Test Reports (CMTRs) related to VJM, PSI and Chevs Landing Metal Manufacturers Incorporated (CLM).

Attached is a listing of eight applications, both safety-trlated (SR) and non-safety-related (NSR), in which documentatioa for the suspect VJH and PSI material was found.

No CLH material vas identified.

Alabama Pover Company, as a member of NUMARC, has monitored the ongoing NUMARC discussions with the NRC on means by which appropriate testing could be performed for suspect VJil and PSI flanges and fittings.

Based upon guidance received at a June 30, 1988 NUMARC vorkshop, testing of accessible safety-related suspect flanges and fittings was to be performed as follovs hardness testing for carbon steel, magnetic testing for stainless steel.

Testing for non-safety-related flanges and fittings was to be performed, if necessary, after the data fro 1 all utilities developed in response to the bulletin had been evaluated by NUMARC.

Inaccessible flanges and fittings, as provided by the bulletin, vould require a justification for continued operation (JCO).

0809140297 800907 lk PDR ADOCK 05000340 Q

P >h) s\\

l U. S. Nuclear Regulatory Commission September 7, 1988 Page 2 In accordance with this guidance, Alabama Power Company has taken the f

following actions:

Inaccessible safety-related flanges JC0 deve)oped Accessible safety-related carbon steel flanges all flanges replaced and hardness testing performed 4

i tensile and chemical testing on a sample flange performed i

i i

Accessible safety-related stainless steel flanges (Accessible only for limited activities such as magnetic testing)

I magnetic testing on all flanges performed I

tensile and chemical testing on a sample flange of each heat performed Non-safety-related flanges

(

)

testing not initiated l

a The results of all testing performed on the suspect flanges satisfied the I

i applicable material specifications. Vith the issuance of Supplement 2 to NRC Bulletin No. 88-05 temporarily suspending field measurements, testing, records reviev and preparation of JCOs, Alabama Power Company considers its l

actions with respect to this bulletin to be complete pending additional NRC j

1 3

guidance.

i

[

If there are any questions, please advise.

l l

Respectfully submitted, f

1

)

ALABAMA POVER COMPANY i

Q.

]

V. G. Hairston, III VGH,III/JARidst-V8.19 Attachment i

cci Mr. L. B. Long SVORN TO AND SUBSCRIBED BEFORE ME I

Dr. J. N. Grace I

Mr. E. A. Reeves T IS h DAY F ht, 1988 J

Mr. G. F. Maxwell l

, D% k

\\ (

j NotaryPpJic' My Commission Expires bc2h-N 1

I j

l 4

-._-___-,.___,-,-__---m_,.,.,

. -, - - -.. -. - _, ~ _ _ _ -, - - - - - _, _ _ _ _ _. _ ~. _ _,... - -, - _. _ _, - - - - -,.

BDEEEE 1791 NGEE OF A9E/ASIM St-ORADI W 10.

GNUeft APPIlCATIGi GMNITIT MAIEUR RKII!C Spit'IFICATE N MR MEKEE**

'IESIIlC1BMIES 1.

FInge Pipirg m service inter 11 0.75 150 SA105 IGt West Jersey /

No testirg, no action return from M7 Motor Capital Pipe rwrenary. 9 installert, Air Qx,lers or EDtS

& Steel Products / 2 previously diW.

Onillers. Pfe 1/Plc 2 J. E. Imier3m Norxxide B31.1 pipirg.

2.

Flage A Train Servim hter 12 6.0 150 SA1Q5 MR FSU No testirg, no action i

Strainer Radamdi Line.

Omsolidated rwre aary. 2 installed, Pfe 1 Pbuer***

10 on hold in storeroom.

Non-code 101.1 pipirg.

l l

3.

Flage R:P Motor Imuer Bearing 12 1.0 150 SA105 St West Jersey /

No testirg, flarges l

coolirg unter Sely.

Osyen Alloys /

i - ible - J00 l

M1 Metal mall =s in effect.

1 4.

Flage letSI Ptsp Coolirg Unter 15 2.0 150 SA105 St Uest Jersey /

All items replarvel.

S e ly. Pte 1 Capital Pipe Harthiess and sample

& Steel tensile and chemical testirg Products perfoomed with wreptable remits.* 12 vere insta11eri. 3 spare.

l 5.

Flage Test equipment use m1y.

2 2.0 300 SA105 IGt Uest Jersr*/

No testirg, senterial Consolidated previously diwarded.

Pipe & S w ly i

Co.

6.

Flage Test quipumt see only.

5 0.75 330 SA105 let Uest Jersey /

No testirg, material Omsolidated previously disorded.

Pipe & Supply co.

7.

Flarge Test equipment use only.

3 0.75 1500 SA105 IGt Umst Jersey /

No testirg, asterial Conmlidated previously discarded.

Pipe & Sgply ca.

O

,n

-,.-,,-,n

Attaduunt Page 2 171m sentBE &

A9E/ASDI SR-OBUN &

10.

OMTBetr AFfUCKIIIN GWt1 TIT DufEIER RATDC SPH2FICKrICN IGt M3(EME**

1ESTDC/IEWE5 8.

Flange Flet homes m Service 384 3.0 150 SA182 9t FSI/

All items remived Unter to Cataisuunt Rahor Alloys /

m inplace magnetic Coolers. IW IMDr 2 Metal Bellous test diidi indicated they were not supietic.

Tensile ard chemical testing as performari l

m a M e of enda heat with acceptable results.*

Acogtable results unans material as found to meet specificatim requirements.

    • Source of material.
      • Although the purchase order gives the n=g=rry's ruse as Canolidated Ibuer, the Company is actually Consolidated Pipe and Sgply Co.

l l

e

. - - _