Forwards Safety Evaluation Accepting 880303 Request for Partial Exemption from App J, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors. Acceptance Based on Local Leakage Path That Is Isolable & Testable
ML20154A955
Person / Time
Site: Waterford Entergy icon.png
Issue date: 05/05/1988
From: Calvo J
Office of Nuclear Reactor Regulation
To: Dewease J
LOUISIANA POWER & LIGHT CO.
Shared Package
ML20154A958 List:
References
NUDOCS 8805160273
Download: ML20154A955 (4)


Text

_-_.. _ _ - _

Un 4

'x Docket No. 50-382 Mr. J. G. Dewease Senior Vice President - Nuclear Operations Lcuisiana Power and Light Company 317 Baronne St., Mail Unit 17 New Orleans, Louisiana 70160

Dear Mr. Dewease:

SUBJECT:

CONTINUATION OF CONTAINMENT LEAKAGE PATE TEST WITH EXCESSIVE LOCAL LEAKAGE By letter dated March 3, 1988, Louisiana Power and Light Company (LPAL) requested a partial exemption forn Appendix J, "Primary Reactor Containment Leakage Testing For Water-Cooled Power Reactors." The request was to allow for a method to successfully complete the Containment Integrated Leakage Rate Test (CILRT) when it is determined that excessive local leakage exists. The method described in the LP&L letter has been reviewed and as described in the attached Safety Evaluation, is an acceptable rethod for successful completion of the CILRT. The local leakage path must be isolable and testable and the "as found" and "as left" condition used to conservatively determine containment integrity and subsecuent frequency of testing. As such, the method proposed and detailed in the Safety Evaluation is approved.

We have further reviewed your Updated FSAR and believe LP&L is approaching the acceptable means although the Updated FSAR does not explicitly address each of the test provisions.

If the LPAL program includes the provision noted in the Safety Evaluation, it meets the requirements of Appendix J and an exemption is not required.

If this is not the case, LP&L should restate the exemptien request and provide more explicit description of the Updated FSAR provisions.

Sincerely,

/s/

Jose A. Calvo, Director Project Directorate - IV Division of Reactor Projects - III, IV, Y and Special Projects

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION

- Docket File [

NRC PDR Local PDR PD4 Reading L. Pubenstein J. Calvo P. Noonan D. Wigginton OGC-Rockville E. Jordan J. Partlow ACRS (10)

PD4 Plant File

  • See previous concurrence PD4/LA*

PD4/PM*

PD4/D /N PNoonan DWigginton:kb JCalvo 05/05/88 05/05/88 05/g/88 8805160273 000505 PDR ADOCK 05000302 P

PDR l

i Docket No. 50-382 Mr. J. G. Dewease l

Senior Vice President - Nuclear Operations l

Louisiana Power and Light Company l

317 Baronne St., Mail Unit'17 New Orleans, Louisiana 70160

Dear Mr. Dewease:

SUBJECT:

CONTINUATION OF CONTAINMENT LEAKAGE RATE TEST WITH EXCESSIVE LOCAL LEAKAGE l

By letter dated March 3, 1988, Louisiana Power and Light Company (LPAL) requested a partial exemption form Appendix J. "Prirrary Reactor Containment Leakage Testing For Water-Cooled Power Reactors." The request was to allow for l

a method to successfully complete the Containment Integrated Leakage Rate Test (CILRT) when it is detemined that excessive local leakage exists. The method described in the LP&L letter has been reviewed and as described in the attached Safety Evaluation, is an acceptable method for successful completion of the CILRT. The local leakage path must be isolable and testable and the "as found" and "as left" condition used to conservatively detemine l

containment integrity and subsequent frequency of testing. As such, the method proposed and detailed in the Safety Evaluation is approved.

Sincerely, 1

l Jose A. Calvo, Director i

Project Directorate - IV Division of Reactor Projects - III.

IV, V and Special Projects

Enclosure:

As stated t

cc w/ enclosure:

See next page l

DISTRIBUTION Docket File NRC PDR Local PDR PD4 Reading L. Rubenstein J. Calvo P. Noonan D. Wigginton OGC-Rockville E. Jordan J. Partlow ACRS(10)

PD4 Plant File S/

PD4/LQ PD4/

PD4/D PNoona DWi inton:kb JCalvo 05/c /88 05/ /88 05/ /88

/

'o UNITED STATES Ig NUCLEAR REGULATORY COMMISSION

[

g D

E W A&M NGTON, D. C. 20H5 May 5,1988

'+,..... o Docket No. 50-382 Mr. J. G. Dewease Senior Vice President - Nuclear Operations Lcuisiana Power and Light Company 317 Baronne St., Mail Unit 17 New Orleans, Lcuisiana 70160

Dear Mr. Dewease:

SUBJECT:

CONTINUATION OF CONTAINMEhT LEArAGE PATE TEST WITH EXCESSIVE LOCAL LEAKAGE ByletterdatedMarch3,1988,LouisianaPowerandLightCompany(LP&L) requested a partial exemption from Appendix J. "Primary Reactor Containment Leakage Testirg for Water-Cooled Power Reactors." The request was to allow for a method to successfully ccmplete the Containment Integrated Leakage Rate Test (CILRT) when it is deterrined that excessive lccal leakage exists. The method 6

descrited in the LFll letter has been reviewed and as described in the attached Safety Evaluation, is an acceptable method for successful completion of the CILRT. The local leakage path must be isolable and testable and the l

"as fcurd" and "as left" condition used to conservatively determine contairrent integrity and subsecuent frequency of testing. As such, the niethod proposed ar.d detailed ir the Safety Evaluation is approved.

We have further reviewed your Updated FSAR and believe LP&L is appecaching the acceptable means although the Updated FSAR does not explicitly address each of the test provisions.

If the LP&L program includes the prevision noted in the Safety Evaluation, it meets the requirements of Appendix J and an exemption is not required.

If this is not the case, LPAL should restate the exemption request and provide more explicit description of the Updated FSAR provisions.

Sincerely, 4

N[W

/ p -s.

i Jose A. Calvo, Director Project Directcrate - IV Division of Reactor Projects - III.

IV, V and Special Projects

Enclosure:

As stated

)

cc w/ enclosure:

See next page 1

i i

I

e i

i I

Mr. Jerrold G. Dewease Waterford 3 Louisiana Power & Light Company cc:

W. Malcolm Stevenson, Esq.

Regional Administrator, Region IV Monroe & Leman U.S. Nuclear Pegulatory Coemission1 1432 Whitney Building Office of Executive Director for i

New Orleans, Louisiana 70103 Operations 611 Ryan Plaza Drive, Suite 1000 Mr. E. Blake Arlington, Texas 76011 Shaw, Pittman, Potts & Trowbridge l

2300 N Street, NW Mr. William H. Spell, Administrator i

Vashington, D.C.

20037 Nuclear Energy Division Office of Environmental Affairs Resident Inspector /Waterford NPS Post Office Box 14690 Post Office Box 822 Baton Rouge, Louisiana 70898 Killona, Louisiana 70006 Mr. Ralph T. Lally President Police Jury Manager of Quality Assurance St. Charles Parish Middle Scuth Services, Inc.

Hahnville, Louisiana 70057 Post Office Box 61000 i

New Orleans, Louisiana 70161 Chairman Louisiera Public Service Commission One American Place, Suite 1630 Baton Rouge, Louisiana 70825-1697 i

Mr. R. F. Burski, Acting Nuclear Safety and Eegulatory Affairs Manc;ce Louisiana Power & Light Company 217 Baronne Street New Orleans, Louisiana 70112 i

i

+

I