I PHILADELPHIA ELECTRIC COMPANY PEACH DOTTOM ATOMIC POWER STATION UNIT 1 DECOMMISSIONING REPORT NO. 15 s

JANUARY 1, 1987 THROUGH DECEMBER 31, 1987 SUBMITTED TO THE UtJITED STATES 110 CLEAR REGULATORY COMMISSIO!1 PURSUAliT TO PROVISIOtlAL OPERATIllG LICEllSE NO. DPR-12 0009130073 000030 l

PDR ADOCK 05000171 l'NU I

l

FEACH BOTTOM UNIT 1 CONTAINMENT AND EXCLUSION AREA INSPECTIONS 1987

/

INSPECTION

SUMMARY

ST 12.12, the semi-annual Unit 1 Exclusion Area Inspection, was performed in December 1986 and July 1987.

Neither of these inspections revealed any unacceptable physical or radiological conditions.

In addition, periodic inspections were performed to monitor water conditions inside the exclusion area.

As noted in i

previous Unit 1 Annual Decommission Reports, inspections of the exclusion area have revealed a moisture spot in the lower basement of the containment.

The inspections covered by this report revealed no significant change in the size of the moisture spot (currently less than 10 square feet).

The most probable source of the moisture is in-leakage of rain water.

No additional areas of accumulating water were discovered.

Water samples obtained for radiological analysis and radiological surveys performed during all inspections have revealed no significant i

activity or radiation levels.

{

I i

t e 1

o 1

i i

4 I

r I

1 PHILADELPflIA ELECTRIC COMPANY Peach Bottom Atomic Power Station Unit No. 1 1987 Annual Decommission Report Docket No. 50-171 8'

The following summarizes the status of the Peach Bottom Unit No. 1 Decommission racility for the year 1987, based on the semi-annual inspections required by Technical Specification Requirement 8.2.4(a).

1.

There is no significant damage or structural deterioration observed in the security fence surrounding the exclusion area.

2.

There is no significant damage or structural deterioration observed in the containment vessel, spent fuel building enclosure, or radwaste room within the exclunion area.

3.

There is no significant damage or structural deterioration observed in the designated barricades within the exclusion area.

4.

There is no condition observed indicating a degradation in the security controls and procedures.

I 5.

There is no evidence of ground water movement between the exclusion area and outside the exclusion area.

(See the attached inspection summary.)

6.

There is no significant change in the radiation or contamination levels in the facility.

7.

There are no removable contamination levels above 100 dpm.

8.

The radiation levels in areas within the scope of the inspection were less than 0.3 mR/hr.

-9 9.

Maximum airborne activity was 1.2 x 10 uC1/cc.

Isotopic analysis identified the source to be a naturally occurring isotope.

10.

The aosolute filter sample on the containment equalization line indicatet i

Radiation Level - less than 0.1 mR/hr.

l, Contamination Level - less than 100 dpm.

11.

There were no abnormal occurrences to 'teport during the year to the NRC as required by Technical Specification 8.2.4(b).

,C

.-s 84My h 4g S ta t iorftrupe r Fht e nlent i

I

-