Topical Rept Evaluation of Proprietary WCAP-8336 & Nonproprietary Suppl 5 to WCAP-8110, Ice Condenser Sys Lower Inlet Door Shock Absorber Test Plans & Results. Repts Present Acceptable Design & Testing Program
ML20154A612
Person / Time
Issue date: 11/03/1975
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20154A536 List:
References
FOIA-85-805 NUDOCS 8603040106
Download: ML20154A612 (2)


Text

__

m

(

f NOV 3 1975 I

4 i

i ENCLOSURE Tooical Report Evaludtion

't l

Report Nos:

WCAP-8336 (Proprietary)(and WCAP-8110 Supplement 5 Non-proprietary)

Ice Condenser System Lower Inlet Report

Title:

Door Shock Absorber Test Plans and Results i

May 24, 1974 Report Date:

Westinghouse Electric Corporation-i Originating Organization:

Containment Systems. Branch, Office Reviewed by:

of Nuclear Reactor Regulation Sumary of Topical Report Westinghouse has designed a pneumatic lower inlet door shock absorber t

i.

to replace the phenolic block shock absorber used in the design of the l

ice condenser system approved in the letter. from D. B. Vassallo to C.

Eiche1dinger, dated April 29, 1975. The pneumatic design was selected

~

i because of simplified fabricating procedures, and inspection and l

i maintenance during plant operation.

Report WCAP-8336 describes the new shock absorber design and the series of tests Westinghouse performed to demonstrate that the air box (pneumatic)

~

j lower inlet door shock absorber can reolace the phenolic block shock The test program utilized three prototype and two production j

The tests were identical to the tests performed absorber.

air box shock absorbers.

to demonstrate the adeouacy of the phenolic block shock absorber design.

I The phenolic block shock absorber tests are described in HCAP-8110, Supplements 1, 3 and 4.

i-Sumary of Evaluation A sumary of our evaluation 'of the tests to demonstrate the adenuacy of

+

i the phenolic block shock absorber design was presented in l

l April 29,1975,the air box lower inlet door shock absorber were the same as tho l

We find that these tests are adeauate the phenolic block shock absorber.to demonstrate the acceptability of l

. absorber design for use in ice condenser type plants.

l U & b 860216 DAyBS-805 PDR 8

8 h

(

NOV 3 1975 2_

Sumary of Staff Position We conclude that WCAP-8336 presents an acceptable design and testing program. for the air box lower inlet door shock absorber.

We find WCAP-8110, Supplement 5 an acceptable non-proprietary version of WCAP-8335.