i ENCLOSURE Tooical Report Evaludtion
't l
Report Nos:
WCAP-8336 (Proprietary)(and WCAP-8110 Supplement 5 Non-proprietary)
Ice Condenser System Lower Inlet Report
Title:
Door Shock Absorber Test Plans and Results i
May 24, 1974 Report Date:
Westinghouse Electric Corporation-i Originating Organization:
Containment Systems. Branch, Office Reviewed by:
of Nuclear Reactor Regulation Sumary of Topical Report Westinghouse has designed a pneumatic lower inlet door shock absorber t
i.
to replace the phenolic block shock absorber used in the design of the l
ice condenser system approved in the letter. from D. B. Vassallo to C.
Eiche1dinger, dated April 29, 1975. The pneumatic design was selected
~
i because of simplified fabricating procedures, and inspection and l
i maintenance during plant operation.
Report WCAP-8336 describes the new shock absorber design and the series of tests Westinghouse performed to demonstrate that the air box (pneumatic)
~
j lower inlet door shock absorber can reolace the phenolic block shock The test program utilized three prototype and two production j
The tests were identical to the tests performed absorber.
air box shock absorbers.
to demonstrate the adeouacy of the phenolic block shock absorber design.
I The phenolic block shock absorber tests are described in HCAP-8110, Supplements 1, 3 and 4.
i-Sumary of Evaluation A sumary of our evaluation 'of the tests to demonstrate the adenuacy of
+
i the phenolic block shock absorber design was presented in l
l April 29,1975,the air box lower inlet door shock absorber were the same as tho l
We find that these tests are adeauate the phenolic block shock absorber.to demonstrate the acceptability of l
. absorber design for use in ice condenser type plants.
l U & b 860216 DAyBS-805 PDR 8
8 h
(
NOV 3 1975 2_
Sumary of Staff Position We conclude that WCAP-8336 presents an acceptable design and testing program. for the air box lower inlet door shock absorber.
We find WCAP-8110, Supplement 5 an acceptable non-proprietary version of WCAP-8335.