. e L-pcp l

~ AMENDMENT OF SOLICITATION / MODIFICATION OF CONTRACT

"[ #

"*"', [ "

3o.

p

'1 4 AM(NOWENTrMODinCATION NO.

j 3 EFFECTIVE DATE ftEQut$ MON PURCHASE RLQ NO

5 PROJECT NO lit appiu.etnei 125 i~9/.30/98 l NMS97-009 9/30\\98 j 7. ACMINISTERED BY lit other itsan trem 6) i e essuts By Coog u._ _.

core g

. U.L Nuclear Regulatory Cosmiission I

l Division of Contracts and Property Ngt.

Attn: T 7 t-2

W:shington DC 20555

~ ~.. ~

4 eMME AND ADDRESS OF CONTRACTOR INo, strec. Leursty State and DP Code) ix) l9A. AMENDMENT OF $0LXITATiON r40

90. DATED (SEE ITEM t il

$0uthwest Research Institute 6220 Culebra Road, Po Drawer 28513 i~

San Antonio TX 78228 0510 10A uOoincATiON OF CONTRACTIORotR NO WIstey C. Patrick, Presidern, CWRA

210 522 5158 TIN # 74 1070544-~

Con # NRC-02-97-009 108.DATEDr$6EITEM 13)

~

~

hf

]FAciLny cOoE X

10-15-1987

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS R Thb above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers]iq extended, ]is not exand9d.

hff tts must acknO'wledge receipt of this amendment pnm to the hour and date specified in the solicitation nt as amended, by one of the follOwing methods; (al By completing items 8 and 15, and returrks copies of the amendment; (b) By acknowledging receipt of this amendment of each copy of the offer submitted; or (c) By sentate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR AC.

A40WLf.DGMENT TO BE RECCIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECif4E0 MAY j

RESULT IN REJECTION OF YOUR OFFEft if by virtue of this amendment you desire to change an ofler aiready submitted, such change may be made bw ttirgram or letter, provided each telegram Or letter makes rete
rence to the solicitation and this amendn 3nt, and is received prior to the opening hour and dite specified.

j obtigatet 533,000

)

-t a ACCOUNTING AND APPROPRIATIOh DATA lit emo weta B&R E 01112200L K#J11 BWOC_212A_Amta_31K0200 13.THIS ITEWI APPLIES ONLY TO MODIFICATIONS OF CONTRACTS / ORDERS, IT MODIFIES THE CONTRACT /CFIDER NO. AS DESCRIBED IN ITEM 14.

ix)

A. THI$ CHANGE ORDER IS ISSLED PURSUANT rO- (Specofy authontyl THE CHANGES SEr FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDfR NO IN ITEM loa i

S THE A80VE NUMBERED CONTRACTIORDER #s MOOlFIEO TO REFLECT THE ADMINISrRATIVE CHANGES (such as changes m paysng othce, app #opriation aate. etc )

,f,ET FORTH IN ITEM 14. RJR$UANT TO *iHE AiJ1HORITY OF F AR 43 to3tte C. THl$ $UPPLEMENTAL AGREEMENT l$ ENTERED INTO PURSUANT TO AJTHORITY OF.

i i

D OTHER (Specify type of modificanon and autronty)

+

x }is ett, O is required to sign this document end return copies to the issuing Office.

E. IMPORTANT: Contractor 14 DEsCfternON OF AMENOMENTIMOOfFICATION (Organued by UCF section hea$ngt meloding soi c<tenoe>contr ct sotaect matter where leasible i Please see attached.

1 fo.

i, i

u

/

9810020324 980930 PDR CONTR

_ ~.R PD l

NRC-02-97-O.O9 i

i I

l.

Encept as prowded haveuL oil terms and conditrons of the document reierenced en hem 9A or toA. as heretofore changed. remains unchanged and in tuli torce and ef te:.

16A. NAME AND TrTLE OF CONTRACTING OFFICER (Type or pant) 16A. N,t.ME ANO TITLE OF siGNLR (Type or pnnt) b Barbara D. Meehan 15C. DATE SIGNED

168, ED si AIES OF AMERICA t6C. ATE SIGNtD 158 CONTRACTOH/OFrEROR kLAd.e.2 b VM (Ih I8 (s.on iu or Conu..nn, Othceo
09 30-1998 (signaives of pee.on authorued to sign)

STANDARD FORM 30 #tEV 483)

- - = ~.... -.

Description of Changer incorporated by Modification No.125 to NRC-02-97-009 l

Page 2

~

v l

The purpcse of this modification is to obligate $33,000 to Job Code J5186. Accordingly, the following changes are made; l

Section B.2.C.b, and d are revised to show the new obligated amount of $12,612,.270,and to l

. obligate $33,000 to Job Code J5186 as shown on the attached change pages 5, and 6.

All other terms and conditions of this contract, including the ceiling amount for the second renewal period of $87,611,477.00, remain the same.

A summary of new obligations for the second renewal period of this contract is given below:

Job Code D1035 (HLW)

Total FY97 Obligation amount $445,000 (see Spent Fuel (CIS) below)

Total FY98 Obligation amour,t $10,773,270 Cumulative Total of NRC Obligations for JC 1035 (HLW) $11,218,270.

Job Code D1035 (Spent Fuel (CIS))

Total FY97 obligation amount $200,000 Total FY98 obligation amount $250,000 Cumulative Total of NRC Obligations for JC 1035 (SP CIS) $450,000.

Job Code J5164 (Tank Waste Remediation)

Total FY98 obligation amount $250,000 Cumulative Total of NRC Obligations for JC J5164 $250,000.

Job Code J5206 (Spent Fuel Dry Transfer)

Total FY97 obligation amount $25,000.

Total FY98 obligation amount $200,000.

Total FY98 deobligation amount $33,000 Cumulative Total of NRC Obligations for JC J5206 $192,000.

l 1

l e,

I lo e

Description of Changes Incorporated by Modification No.125 to NRC-02-97-009 Page 3

?

Job Code J5210 (Aluminum-Based Spent Fuels)

L Total FY98 obligation amount $125,000.

1 l

Cumulative Total of NRC Obligations for JC J5210 $125,000 l

i l

i Job Code J5186 (TMI 2 Fuel Debris).

l-Total FY98 obligation amount $208,000.

?

Total FY98 deobligation' amount $8,000.

Cumulative Total of NRC Obijations for JC J5186 $200,000.

l Job Code J5226 (Private Fuel Storage)

. Total FY98 obligation amount $158,000 l

Cumulative Total of NRC Obligations for JC J5226 $158,000 l

This modification obligates $33,000.

l l

t i

7..-

_ ~.

NRC-02-97-009 Modification No.125 Page5

e. Total amount authorized by Operations / Project Plans' was as follows:

High-Level Waste Licensing Support System Job Code: D1035 Job Code: L1590 Amount:' $ 44,662,918

. Amount: $35,900 Research Waste Solidification Systems Job Code: 86666 Job Code: L1793 Amount: $ 15,584,461.47 Amount: $642,391.87 Job Code: J5190 Amount: $39,900 Transportation Monitored Retrievable Storage Job Code: D1070 Job Code: L2516 Amount *"

Amount: $20,459.70 Tank Este Hemediation Safety Review of TMI-2 Job Code: J5164 Job Code: J5186 Amount: $772,035.00 Amount: $158,290 Total amount authorized: $ 61,916,356.04

f. The total award fee availablo; the award fee earned thus far and the evaluation period applicable thereto were as follows:

Available Award Fee Evaluation Period Award Fee Earned 11 9/27/92-4/9/93-

$309,465 259,951 12 4/10/93-9/24/93 347,645 316,673 13 9/25/93-9/30/94 709,894 668,010.43 14 10/1/94-9/29/95 817,617' 793,088 15 9/30/95-9/27/96 665,948 645,970

'16 9/28/96-9/26/97 556,736 528,899 Current Data C. Seotember 27.1997 - Seotember 27. 2002

. a; The total estimated ceiling amount of this Cost-Plus-Award-Fee type contract for the above mentioned period is $87,611,477.00.

b.

The amount presently obligated by the Government with respect to this contract for this period is 5 12,612,270. In addition, carryover funds in the amount of l

$3,302,599.76 are available for use in this renewal period as indicated below.

l

. The' award fee pool will be as stated in the AFDP. The plan will reflect the actual award fee pool based on cumulative estimated costs for performance of approved

~ Operations / Project Plans. The arip!! cable base fee percentage is also described in the AFDP.

i.

l

NRC-02-97-009 Modification No.125 Page 6 Evaluation of the sward fee earnpd.will be accomplished in accordance with the c.

then current AFDP (Attachment 11). Weither the determination as to the amount of fee available during a given period, the amount of award fee earned, nor the determination of the criteria under which the subject award fee will be made, shall be subject to FAR Subpart 52.233-1, entitled, " Disputes". ~

d.

Total funds currently obligated by Job Code (JC) are as follows:

High-Level Waste Waste Solidification Systems Job Code: D1035 Job Code: L1793 New Funds: $ 11,237,270 New Funds:

Carryover: $1,989,455.71 Carryover: $2,763.35 j

Total: $13,226,725.71 Total: $2,763.35 Tank Waste Remediation Waste Solidification Systems Job Code: J5164 Job Code: J5190 New Funds: $250,000 New Funds:

Carryover: $1,496,284.95 Carryover: $35,349.05 Total: $1,746,284.95 Total: $35,349.05 l

Spent Fuel (TMI 2 Fuel Debris)

Spent Fuel (Dry Transfer)

Job Code: J5206 Job Code: J5186 New Funds: $208,000 New Funds: $225,000 Deob.: $8,000 Deobligate: $33,000 Carryover: $28,746.69 Carryover: $0 Total: $228,746.69 Total: $192,000 Aluminum-Based Spent Fuels Spent Fuel (CIS)

Job Code: J5210 Job Code: D1035 New Funds: $125,000 New Funds: $450,000 Total: $125,000 Total: $450,000 Spent Fuel (PFS)*

Job Code: J5226 New Funds: $158,000 Total: $158,000 Total New Funds Obligated for 2nd Renewal Period: $12,653,270 Funds Deobligated during 2nd Renewal Period:

41,000 Net Obligated:

$12,612,270

  • PFS is subject to the license fee recovery provisions located elsewhere in this contract.

The TAC number for this project is L22462.