NUCLEAR ENGINEERING SCIENCES DEPARTMENT Nuclear Reactor Facility University of Florido m.S.Vemof oon, Dvoctor NUCHAR REACTOR 80lLhNG Goinevlie,Florido 32411
,g.
n.a. poo m.u29. Toe smo May 6, 1988 United States Nuclear Regulatory Commission Atta: Document Control Desk Washington, D.C.
20555 Re:
Reply to Notice of Violation Inspection Report No. 50-83/88-01
Dear Sir :
This report is divided into two parts to address the two violations cited in Inspection Report No. 50-83/88-01.
A.
Inspection Report No. 50-83/88-01 cites the UFIR f acility with a Severity Level IV violation for failure to conduct adequate surveys to evaluate the extent of radiation hazards present in liquid and gaseous effluents released from the facility in two cases as quoted here:
1.
For measurements of Ar-41 in gaseous effluents, the gamma spectro-scopy detection system was calibrated using a 1,000 cubic centimeter (cc) matrix calibration standard and sample concentration results were calculated for a 1.000 cc sample volume. The actual volume of the sample container utilized to measure concentrations in Ar-41 gaseous effluents was 1,250 cc.
2.
The lower limit of detection for liquid waste tank effluent analy-ses, 1.08 E-7 microcuries per milliliter (pCi/ml), was greater then 25% of the concentration (4.0 E-7 pCi/ml) allowed for release to the sanitary sewer and the individual isotopes present in the effluent were not identified as required by Technical Specifications.
la.
Adminsion or Denial of the Violation 1)
For the Ar-41 measurements, the statement of violation repeated above is admitted; however, this methodology has been con-sidered conservative.
2)
For the failure to identify individual isotopes present in the liquid effluent, the statement of violation is also admitted, though no credit for dilution is taken for the radioactivity level in the liquid effluent.
Ems omevevermcrw Ac+en twve,.e
\\
(
,8805130010.880506 PDR ADOCK 05000083
,ri re n..
i, -
m
.s U.S. Nuclear Regulatory Commission '
May 6, 1988 Page Two Ib.
Reasons for the Violation li' The. reason for the violation on Ar-41 measurements is the be-lief that the methodology in use was conservative, though ad-mittedly not as accurate as possible. The methodology had been reviewed independently by an Environmental Engineering Profes-sor; though he had documented his walk-through review of the Argon-41 measurement considering the procedure adequate, he did not document any consideration of whether the measurement is conservative.
2)
The reason for the violation involving failure'to identify in-dividual isotopes in the liquid effluent is that releases are usually less than 5-10 per cent or.less of allowed release con-centrations. Such a concentration was probably applicable on the one 1986-1987 release for which we are cited. The 1.08E-7 pCi/ml value is the lower limit of detection, not an actual quantified release concentration. The only reason for the quoted 1.08E-7 pCi/ml level in the effluent is that the count time for the sample was shortened representing an increase in the lower limit of detection to the point where the LLD was greater than 25% of the allowable release concentration. As a result there was an oversight for the monitoring requirement for specifying individual isotopes for inclusion in the Annual Report per Paragraph 6.6. l(5) of the UFTR Technical Specifica-tions.
Ic.
Corrective Steps Taken/Results Achieved 1)
The next scheduled Argon-41 measurement will not be performed until we have documented analysis to assure the conservatism of the present methodology or obtained a calibration source tYat more closely models the 1250 cc sample containers and performed an appropriate evaluation for its use.
2)
No f urther liquid releases have been made since the t'RC inspec-tion on March 14-17, 1988. When releases are next made samples will be counted sufficiently to assure the activity level is below 25% of that allowed or the contributing individual iso-topes will be identified. It is worth noting : hat two liquid wastereleasesin,geptember, 1987 and another in January, 1988 average 2.96 x 10 pCi/mi which is only about 7.4% of the al-lowable concentration. All three have been well below the 25%
cutoff for requiring identification of individual nuclides.
U.S. Nuclear Regulatory Commission May 6, 1988 Page Three Id.
Corrective Steps to be Taken to Avoid Further Violations 1)
The Argon-41 methodology is being reviewed as part of a student project under the direction of the Director of Nuclear Facili-ties.'In addition, a new calibration source at 1250 cc is being ordered and should be available for the next Argon-41 measure-ment due in June, 1988 and required by August, 1988.
2)
The Radiation Control Technique procedure #21 used to control sampling and release of liquid effluents will be reviewed and approved by the Director of Nuclear Facilities and it will be revised to assure all changes to the technique are adequately reviewed prior to implementation bef ore any further releases are made from the holdup tanks. A revised version of Radiation Control Technique #21 is currently under review with approval expected by May 31, 1988.
le.
Date When Full Compliance Will Be Achieved 1)
Full compliance hcs effectively been achieved as of the NRC In-spection, in that certain evaluations of the current methodo-logy and/or acquisition of a new calibration source will be accomplished before the next Argon-41 measurement due in June, 1988 with a 2 month window allowed. The corrective steps to be taken to avoid further violations in the monitoring of gaseous effluents per Section Id.1) above will be completed by August 31, 1988.
2)
The corrective steps to be taken to avoid further violations in the monitoring of liquid effluent releases will be implemented fully by June 15, 1988.
B.
Inspection Report No. 50-83/88-01 cites the UFTR facility for a Severity Level IV violation for f ailure to f ollow Technical Specification 6.3 re-quiring that the facility be operated in accordance with approved written procedures. All procedures and major revisions thereto shall be reviewed and approved by the Director of Nuclear Facilities before going into ef-feet. Contrary to the above, for the reporting period from September 1, 1986, to August 31, 1987, the licensee is cited for failure to have the Director of Nuclear Facilities approve the Radiation Control Technique procedures used to conduct environmental surveillances and effluent re-lease measurements required by Technical Specifications.
a.
Admission or Denial of the Violation The violation is admitted.
U.S. Nuclear Regulatory Commission May 6, 1988.
Page Four b..
Reason for the Violation The manual of Radiation Control Technique Procedures has been de-veloped by the Radiation Control Office to serve the entire Univer-sity of Florida campus. Some of the Techniques applicable to the UFTR have been in the manual for many years prior to the relicensing of the UFTR in 1982 when the procedures were required to be reviewed by the Director of Nuclear Facilities. As a result, they were grand-fathered in for the facility and occasionally updated (improved) by the Radiatior Control Office, sometimes based on input from the UFTR staff and management. However, because of the historical development of these Radiation Control Techniques, they were not formally docu-mented as reviewed by the Director of Nuclear Facilities. The fail-ure to do so is an oversight, c.
Corrective Steps Taken to Date/Results Achieved All applicable Radiation Cont ol Techniques used on a frequent basis have been reviewed by the Director of Nuclear Facilities as of May 5, 1988 to assure no unreviewed Radiation Control Techniques pro-cedures are used to support operation of the UFTR facilities. This step is assuring that this violation will not recur.
d.
Corrective Steps to be Taken to Avoid Further Violations As a group all the Radiation Control Techniques used to support op-eration of the UFIR f acility are being reviewed by the Director of Nuclear Facilities and current copies will then be maintained in a separate notebook at the UFTR facility with a cover page documenting a dated review by the Director of Nuclear Facilities. In addition, a memorandum of understanding is being generated between the Radiation Control Office and the Director of Nuclear Facilities to assure changes to these Techniques are reviewed by the Director of Nuclear Facilities prior to implementation to support UFTR operations.
e.
Date of Full Compliance Compliance has been achieved via the interim measure noted in Para-graph (c) as of May 5, 1988. Full compliance with documented review of all applicable Radiation Control Techniques maintained in a sepa-rate notebook will be achieved by July 31, 1988.
U.S. Nuclear Regulatory Commission May 6, 1988 Page Ffvi We trust this response satisfies the requirements delineated in Inspection Re-port No. 50-83/88-01. If there are further questions, please advise.
Sincerely, t
William G. Vernetson Director of Nuclear Facilities WGV/ps cc: NRC Region II Regional Administrator P.M. Whaley J.S. Tulenko Reactor Safety Review Subcommittee (RSRS) a w Y W -v NotarhPublic i