Special Rept Re Evaluation of Units 1 & 2 Containment Tendon Conditions.Grease Voids Were in Excess of 5% in Two Tendons. Voids of 20% or Less Are Considered Reasonable.Containment Integrity Assured
ML20153G254
Person / Time
Site: South Texas  
Issue date: 09/24/1998
From: Thomas S
HOUSTON LIGHTING & POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NOC-AE-000304, NOC-AE-304, NUDOCS 9809300014
Download: ML20153G254 (5)


Text

__

Nuclear Opera ng ompany N

Sm6 has1%$ctEkefrtGemnthgStaku 20 Aw289 Khdmtv4 Tans 77483 m

September 24 NOC-AE-000304, 1993 File No.: G02 10CFR50.36 STI: 30717663 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South Texas Project Units 1 & 2 Docket Nos.: STN 50-498, STN 50-499 Special Report Regarding an Evaluation of Unit 1 and Unit 2 Cpntainment Tendon Conditions Pursuant to South Texas Project Technical Specifications 3.6.1.6 and 6.9.2, the STP Nuclear Operating Company submits the attached Special Report regarding an evaluation of Unit I and Unit 2 Containment tendon conditions.

j There are no licensing commitments in this letter. If you have any questions on this matter, please contact Mr. K. J. Taplett at (512) 972-8416 or me at (512) 972-7162.

S. E. Thomas

Manager, Design Engineering KJT/

Y

Attachment:

Special Report Regarding an Evaluation of Unit I and Umt 2 Containment 4f [

Tendon Conditions 9809300014 980924 PDR ADOCK 05000498 S

PDR

~

.3

~'

- \\wW rarc-wk% step 98\\0304 doc o:

.~. - -

e.

a NOC-AE-000304 File No.: G02 Page 2 Ellis W. Merschoff Jon C. Wood Regional Administrator, Region IV Matthews & Branscomb U. S. Nuclear Regulatory Commission One Alamo Center 611 Ryan Plaza Drive, Suite 400 106 S. St. Mary's Street, Suite 700

' Arlington,TX 76011-8064 San Antonio,TX 78205-3692 Thomas W. Alexion Institute of Nuclear Power Project Manager, Mail Code 13H3 Operations - Records Center

' U. S. Nuclear Regulatory Commission 700 Galleria Parkway Washington, DC 20555-0001 Atlanta, GA 30339-5957 Cornelius F. O'Keefe Richard A. Ratliff

~

.s,

~

Sr. Resident Inspector Bureau of Radiation Control c/o U. S. Nuclear Regulatory Commission Texas Department of Health

' O. Box 910 1100 West 49th Street Bay City, TX 77404-0910

- Austin, TX 78756-3189 J. R. Newman, Esquire D. G. Tees /R. L. Balcom Morgan, Lewis & Bockius

~ suston Lighting & Power Co.

1800 M. Street, N.W.

. O. Box 1700 Washington, DC 20036-5869 Houston,TX 77251 M. T. Hardt/W. C. Gunst Central Power and Light Company City Public Service ATTN: G. E. Vaughn/C. A. Johnson P. O. Box 1771 P. O. Box 289, Mail Code: N5012 San Antonio,TX 78296

-Wadsworth,TX 77483 e

A. Ramirez/C. M. Canady U. S. Nuclear Regulatory Commission City of Austin Attention: Document Control Desk 4

Electric Utility Department Washington, D.C. 20555-0001

[

721 Barton Springs Road

}

Austin,TX 78704 wh,"

Attachment NOC-AE-000304 File No.: G02 Page 1 of 3 Special Report Regarding an Evaluation of Unit 1 and Unit 2 Containment Tendon Conditions

Reference:

South Texas Project Unit 1 Licensee Event Report 98-001 dated February 23, i

1998 (NOC-AE-0083)

The referenced correspondence documents a reportable occurrence in performance of previous containment post-tensioning system surveilhnces. The occurrence (limited to the first year surveillance for Unit 2 and the fifth year surveillance for Unit 1) resulted in failure to perform dditional liftoff testing required per Technical Specification Surveillance Requirement a

4.6.1.6.1.a.(2). The South Texas Project committed to retest the affected tendon in each unit and their adjacent tendons by September 1998. During implementation of this commitment, it was discovered that tendon filler grease voids in excess of the Technical Specification Surveillance i

Requirement 4.6.1.6.1.d.(2) maximum of 5 percent of net duct volume existed. Technical

{

Specification 3.6.1.6.b requires i

With the indicated abnormal degradation of the structural integrity other than indicated by conditiondn Specification 4.6.1.6.1.a.(4), at a level below the acceptance criteria of Specification 4.6.1.6, restore the containment (s) to the required level of integrity or verify that containment integrity is maintained within 15 days, perform an engineering evaluation of the containment (s) and provide a Special Report to the Nuclear Regulatory Commission within 30 days in accordance with Specification 6.9.2 or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Grease voids in excess of 5% were present in two tendons in each unit. The voids for the four tendons ranged between 5.7% and 8.4%. Sheathing filler grease was added simultaneously with the discovery of the voids as a result of the inspection process to restore the affected tendons to i

the required level ofintegrity.

The main purpose for the sheathing filler material grease is to provide long-term corrosion protection for the tendon wires and anchorage components. Initial installation of the sheattling filler material involved pumping the heated grease into the tendon sheathing (duct) from one end j

of the horizontal tendon until the hot grease (temperature > congealing point) is ejected from the opposite end of the horizontal tendon with a continuous stream of hot grease flow, free of air bubbles and foreign substances. Additionally, for horizontal tendons routed above discontinuities

. such as a penetration, the sheathing was vented to release entrapped air during grease injection.

Filling the vertical tendons is basically the same, except pumping is performed from both ends of the tendon until the hot grease is ejected from the high point vent located at the apex of the dome.

This installation procedure assured that the tendon had been tnoroughly coated with grease over ohpWm.dW98Mdx

Attachment NOC-AE-000304 File No.: G02 Page 2 0f 3 its entire length including filling the grease caps, thus encasing the tendon-end anchorages. In addition, the tendon wires were coated with e temporary corrosion preventative, Visconorust 1601-Amber, after fabrication for storage and handling of the tendon coil. Furthermore, the tendon wires were hand-coated with Visconorust 2090P-4 (grease) during installation where the temporary corrosion preventative material had been scraped off and to lubricate the tendon for insertion into the duct. This ensured that all of the tendon wires were coated with corrosion inhibitor at the time ofinstallation and maintained corrosion-free through their entire service life.

Grease voids are expected in the tendon ducts. Th percent voids can be in excess of the 5% limit for several reasons which are explained below:

1)

Shrinkage of grease occurs since the grease was initially injected at a temperature between 150 and 250 degrees F. The grease (Visconorust 2090P-4) has a coefficient of expansion which yields an expansion of about 1% per 20 degrees F. Initial installation temperatures are typically greater than 180 degrees F. Depending on the ambient temperature, shrinkage can be in excess of 4%.

L 2)

Spaces exist between the wires in the tendon bundle. The tendon is made up of 186 tightly wound wires. This condition makes it very difficult to fill all spaces between the wires during initial installation because the tendon is at ambient temperature. As the hot grease surrounded the tendon, it is possible that it worked its way into the middle spaces of the tendon bundle. These spaces make up a minimum of 3% of the net duct volume for a given tendon. In addition, this migration of grease may occur in areas where the tendon is in contact with the sheathing, which is r.ot considered in the previous 3%.

3)

The process of pumping grease into the duct entrains air inside the grease. This entrained air can surface from suspen'sion between the time the duct is filled and the surveillance is performed. Additionally, air becomes entrapped while the grease is pumped from one end of the sheathing to the other end, which can be as long as 600 feet. This introduction of entrained aad entrapped air can account for a significant percentage cithe additional grease pumped into the tendon duct during the surveillance.

I Therefore, voids of 20% or less are considered reasonable. There was no evidence of grease j

leakage as determined by performing a visual inspection of the accessible Containment surfaces i

and by holding the pressure for one hour after replacing the grease. A visual examination of

)

eximsed anchorage components from the surveillance tendons as well as the wires removed from j

the detensioned tendons has shown no evidence of degradation.

i I

onwp\\nrarc-wk\\srep-98iO3Rdoc J

  • 'A Attachment l

NOC-AE-000304 l,

File No.: G02 Page 3 of 3 L

As previously stated, the tendon wires and anchorage system were coated with storage or filler grease prior to installation and the ducts were completely filled with filler material from one end of the tendon to the other at initial installation. Special consideration was given to the l

formulation of the filler grease as the original specification required it to have a liquid vapor l

phase inhibitor for the prevention of corrosion within the voids. The filler material was also l

aquired to contain additives to enhance the corrosion-inhibiting and wetting properties, as well as to form a hemical bond with the tendon steel. Therefore, the corrosion protection for the tendons is l

maintained.

Additionally, the manufacturer of the grease has suggested against eliminating voids from the tendon duct due to the coefficient of expansion of the grease discussed in item 1 above, when the grease is installed while Containment ambient temperature is below the upper operating range.

I The duct needs some void area to allow the grease to expand in order not to be detrimental to the tendon sheathing.

In conclusion, grease was initially installed throughout the entire length of the tendon ducts and l

grease coverage wts assured. The grease will adhere to the tendon and protect the wires from l

corrosion. Ther-is a vapor phase inhibitor in the Visconorust 2090P-4 for the prevention of l

conosion within voids as well as additives to enhance corrosion-inhibiting propernes of the grease. The tendons which had voids have been filled and there is no evidence of grease leakage from the sheathing. The remaining tendons in the containment structure are adequate in their existing condition since minimum grease coverage still exists to provide corrosion protection for i

the post-tensioning system. Adequate grease coverage exists for the tendons to maintain corrosion protection and no significant grease leakage is evident, therefore, Containment integrity is assured.

l i

l l:

i 0

0:\\wp\\nfarc-wk\\srep-900304. doc i