ML20153F863

From kanterella
Jump to navigation Jump to search
Forwards Rev 1 to Semiannual Effluent Release Rept 7. Rev Consists of Revised Pages to Correct Compilation Errors in Reporting Total Ci Released of Tritium & Xe-135 Through Gaseous Pathways,As Addressed in Insp Rept 50-352/88-04
ML20153F863
Person / Time
Site: Limerick Constellation icon.png
Issue date: 08/30/1988
From: Alden W
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Russell W
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20153F868 List:
References
NUDOCS 8809070518
Download: ML20153F863 (1)


Text

.

,,e PHILADELPHI A ELECTRIC. COMPANY 23ol MARKET STREET P.O. BOX 8699 PHILADELPHI A PA.191o1 12151841 4000 August 30, 1988 t

Docket No. 50-352 l

l Mr. William T.

Russell i

Administrator, Region 1 U.

S. Nuclear Regulatory Commission ATTN:

Document Control Desk a

Washington, DC 20555 l

t 3

SUBJECT:

Limerick Generating Station Unit 1 l

Seini-Annual Ef fluent Release Report l

No. 7, Revision No. 1 i

i

Dear Mr. Russell:

Enclosed please find two copies of revised pages of the

)

Limerick Generating Station, Unit 1, Semi-Annual Effluent Release Report No. 7.

This revision is being submitted to correct 4

compilation errors in reporting the total Curies released of i

Tritium and Xenon-135 through the gaseous pathways.

These errors have been previously identified and discussed with Mr. B. S.

i Davidson of the NRC and were addressed in Inspection Report No.

l 50-352/88-04.

The pages.affected by this revision are as follows:

)

Table A.2 Summary Page 7

(

Table A.2 Page 1 of 9 Page 8 1

The changes are identified by a vertical bar in the j

right margin.

1 1

These two pages are being issued in accordance with the i

Technical Specifications 6.9.1.8 and Regulatory Guide 1.21 to 4

j fulfill the requirements of Regulatory Guide 10.1.

very truly yours, j

W. M. Alden r

Director l

Licensing Section 1

Nuclear Support Division i

J f

Enclosures i

\\

cci Addressee j

I T. J. Kenny, Senior Site Inspector

(( LEY 0I f

8909070518 880630 I

I PDR ADOCK 05000352 8 )

i i

R PDC