ML20153F703
| ML20153F703 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 09/01/1988 |
| From: | Counsil W, John Marshall TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| CP-87-07, CP-87-7, TXX-88643, NUDOCS 8809070416 | |
| Download: ML20153F703 (1) | |
Text
MFE log # TXX-88643 File # 10110 909.2 TUELECTRIC Ref. # 10CFR50.55(e)
September 1, 1988 ENY$$
U. S. Nuclear Regulatory Commission Attn: Decument Control Desk Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 ITEMS PROCURED TO IMPROPER CODE CLASS SDAR: CP-87-07 (SUPPLEMENTAL REPORT)
Gentlemen:
On February 19, 1988 TV Electric letter TXX-88168 provided notification that the deficiency involving items procured with a Q-code "C" instead of a Q-code "A" was reportable under the provisions of 10CFR50.55(e).
This report is submitted to update the corrective action completion schedule.
TXX-88168 indicated that corrective actions for both Units 1 & 2 would be completed by September 1, 1988. Unit 1 corrective actions have been rescheduled for completion by December 30, 1988 and Unit 2 corrective actions have been rescheduled for completion prior to Unit 2 fuel load.
Very truly yours, U. 6,. Co w ~ 5 i l
{
l W. G. Counsil M
By:
J. S. Marshall Generic Licensing Manager DAR/gj l
c - Mr. R. D. Martin, Region IV i
Resident inspectors, CPSES (3) l 8809070416 880901 PDR ADOCK 05000445
)}
S PDR I
400 Nonh Obw Street LB 81 Dallas, Texas 1SMI i
w