i l
e emes FE Log # TXX-88651 File i 10110 l
=
=
910.4 l
7UELECTR/C Ref. # 10CFR50.55(e)
September 1, 1988 Wmism G. Counsu Laervstn Wr ?>rMent V. S. Nuclear Regulatory Commission Attn: Document Control Oesk Wash.ngton, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET N05. 50-445 AND 50-446 CONDENSATE STORAGE TANK OVERPRESSURIZATION r
I SOAR:
CP-87-28 (SVPPLEMENTAL REPORT) l l
Gentlemen:
l On December 2,1987, we notified you by our letter logged TXX-6992 of a deficiency involving the capacity of the :ondensate storage tank (CST). Our most recent report on this issue, logged TXX-88573, was submitted on July 25, 1988.
This report is submitted to update the corrective action completion schedule for this issue.
l Our implementation of the Unit 1 corrective action for this issue is continuing.
The new estimated completion date for Unit 1 activities is i
December 20, 1988.
The Unit 2 activities will still be completed prior to Unit 2 hot functional testing.
Very truly yours, hb W. G. Counsil By:
O. R. Woodlan Manager Docket Licensing MCP/amb c-Mr. R. D. Martin, Region IV Resident inspectors CPSES (3) k $ N 445 k(f
/
Ei PNU i e 600 Nortk okw steret L881 Ekitu. Tenu !)MI
-