Responds to NRC Ltr Re Violations Noted in Insp Rept 50-425/88-01.Corrective Actions:Independent Review of Pullman Radiographs Enhanced by Increasing Util QC Surveillance to Min of 25% for Remaining Welds
ML20153D240
Person / Time
Site: Vogtle 
Issue date: 05/03/1988
From: Rice P
GEORGIA POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
GN-1450, NUDOCS 8805090089
Download: ML20153D240 (2)


Text

Georgta Fbwer Company Fbst Office Box 282 Waynesboro, Georgia 30830 Telephone 404 554-9961 Extens>on 3413 404 724-8114 Extension 3413 m

Georgia Power p.o.me.

p,,cf N seen muc som fiay 3,1988 United States Nuclear Regulatory Commission ATTN: Document Control Desk File:

X7BG10 Washington, D. C.

20555 Log:

GN-1450 l

Reference:

Vogtle Electric Generating Plant - Unit 2 USNRC Inspection Report 50-425/88-01 Georgia Power Company wishes to submit the following information concerning the violation identified in the referenced inspection report.

Violation 50-425/88-01-01, "Rejectable Radiographic Indication in a Code Class 1 System Weld (2-1201-030-W30)"

Georgia Power Company acknowledges the violation as identified in USNRC Report 50-425/88-01.

The

defect, when originally interpreted by Construction, was partially masked by field weldment and evaluated as acceptable.

The Authorized Nuclear Inspector (ANI) reviewed and interpreted the film with the same resul ts.

l Subsequent weld surface preparation (for preservice inspection) and re-radiographing (by NRC) resulted in an interpretation as an unacceptable indication.

The subject weld was reported on Pullman Power Products DR PP-17865 and dispositioned to repair.

The repair was completed and the j

DR closed on January 14, 1988.

To detemine the extent of the violation, an evaluation of the radiograph interpretation program was performed.

There are two programmatic radiograph reviews in addition to the contractor's reading.

These independent reviews, by the Authorized Nuclear Inspector and by GPC Quality Control / Surveillance, are on a sample basis constituting in excess of 25% of ASME Class 2 welds and more than 95% of ASME Class 1 welds.

Additional reviews, on a sample basis, are performed by GPC Quality Assurance during audits and program assessments.

From January 1986 to December 1987 only one in interpretation resultin in a Deviation Report was differenceThat Deviation Report (SQ-675)g was dispositioned use-as-is.

noted.

The same Pullman inspector (who read the subject radiograph) has been used for the past 30 months.

It is Pullman's practice to obtain a second opinion from their NDE Supervisor in cases of a marginal indication.

Based on these conditions, it was concluded that the cited situation is an isolated instance.

8605090089 880503 i

PDR ADOCK 05000425 I

Q DCD i

.v File:

X78G10 May 3, 1988 Log: GN-1450 Page two In addition, to reduce the potential for recurrence, the independent review of Pullman radiographs has been enhanced by increasing the GPC Quality Control surveillance to a minimum of 25% for remaining welds.

Radiograph interpretation has been and remains. at acceptable confidence levels.

Full compliance has been achieved.

This response contains no proprietary information and may be placed in the NRC Public Document Room.

/i abh P. D. Rice PDR/wkl xc:

USNRC - Region II Suite 2900 101 Marietta Street, N. W.

Atlanta, GA 30323 j

H. G. Baker, Jr.

D. R. Altman L. T. Gucwa R. P. Mcdonald J. A. Bailey C. W. Hayes R. H. Pinson G. Bockhold, Jr.

R. W. McManus E. D. Groover G. R. Frederick Sr. Resident (NRC)

C. T. Moore J. E. Swartzwelder D. H. Smith (OPC) l R. A. Thomas A. B. Gallant J. E. Joiner (TSLA)

NORMS 4

-