TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 SN 157B Lookout Place AUG 251988 U.S. Nuclear Eegulatory Comission ATTN: Document Control Desk Washington, D.C.

20555 Centlemen.

a lu the.tatte.' of

)

Docket Nos. 50-259 Tennessee Valley Authority

)

50-260 50-296 BROWHS FERRY NUCLEAR PLANT (BFN) - SYSTEM PRESSURS TEST PROGRAM REQUEST FOR RELIEF (RFR) H-12 As a result of a June 29, 1988 teleconference with members of the NRC staff, TVA has revised its request for relief, H-12, to add valve 85-589 to the ASME Class 2 preisure test boundary.$'The revised request for rollef and a clarification of thik requert, ar'u enclosed. )

In addition the ntaff suggest.ed adding a second valve. 85-229A, to the system pressure test. TVA has reviewed the sufSestion and has determined that the addition of the valve to the test would not increase the margin of safety.

The enclosed clarification, me.:6.Loned above, provides more information concerning TVA's review of this suggestion.

Please refer any questions regardius this mtter to Iatrick Carter at (205) 129-2689.

Very truly yours.

TENNESSE5; vat EY AUTHORITY

/

R. Gridley, M ager Nuclear Licensing aed Regulatory Affairs Encionucos cc:

See page 2

=

p G809020104 880325 gDR ADOCK0500g9

{

An Equal Opportunity Employer

e J.

U.S. Nuclear Regulatory Commission g$ %

cc (Enclosures):

Ms. S. C. Black, Assistant Director for Projects TVA Projects Division U.S. Nuclear Regulatory Comnission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852

~ Mr. F. R. McCoy, Assistant Director for Inspection Programs TVA Projects Divlsion U.S. Nuclear Regulatory Commission Region II 101 Marie *.ta Street, NW, Suite 2900 Atlanta, Georgia 30323 Browns Ferry Resident Inspector Browns Ferry Nuclear Plant Route 12, Box 637 Athens, Alabama 35611

e

=

a ENCtOSURE RFR H-12 clarification During the NRC's preliminary review of RFR H-12, two areas were identified as needing.further clarification:

1.

ASME Class 2 equivalent 1/2-inch pis uns between valves 85-39A*, 85-589*,

85-590* and the hydraulic accumulators.

2.

ASME Class 2 equivalent boundary from the hydraulle accumulators water side to valve 85-229A*.

TVA agrees with NRC's recommendation (item 1) of extending the ASME Class 2 boundary to 85-589*.

It appears that 85-589* was inadvertently omitted in defining the hydrostatic test boundary.

In accordance with NRC Regulatory Guide 1.26, 85-589* serves as the boundary valve for the ASME Class 2 boundary.

Based upon review of HRC Regulatory Guide 1.26, discussion with BFN Mechanical Test Section personnel, and performance of the system hydrostatic test method, TVA is justified in stopping the ASME Class 2 equivalent boundary on the water side of the hydraulic accumulators for the following reasons:

HRC Regulatory Guide 1.26 only addresses components containing water, steam, or radioactive material. The design configuration of the hydraulic control unit has a piston with pressure seals that require a pressure differential to avoid damage during testing.

This limitation requires nitrogen to be supplied to the opposite side to maintain the pressure differential. During performance of the pressure test, the piston is bottoned out with nitrogen maincaining the pressure differential and manual valvo 85-229A* in 6n open position. Testing in this manner allows the accuculator to serve as an isolation point with valve 85-229A*

remaining in an open position.

TVA believes there would be no increase in the margin of safety to extend the test boundary to valve 85-229A* and the current boundary is in accordance with the guidelines of Regulatory Guide 1.26.

  • There are 185 valves with thle number which are denoted by -1 through -185 af ter the flow diagram valve number.

l l

t I

l l

i l

e.

RE00EST FOR RELIEF H-12 UNITS 1,2,3 SYSTEM Control Rod Delve (CRD):

3/4-inch piping between valves FCV 85-39B* and 85-617* and 1-inch and 1/2-inch piping between valves FCV 85-39A*, 85-589*, 85-590*, and the hydraulic accumulators.

CLASS ASME Code Class 2 equivalent TEST REQUIREMENT -

ASME Section XI, 1974 Edition, Summer 1975 Addenda, Paragraph IWC-5220(a).

The system hydrostatic test pressure shall be at least 1.25 times the system design pressure (P )

d and conducted at a test temperaturo not less than 100*F except as may be required to meet the test temperature requirements of IWA-5230.

BASIS FOR RELIEF -

During the analysis of the system for the hydrostatic pressure test, several potential problems were identified that could cause safety concerns with personnel and possible damage to equipment. The portion of CRD piping under evaluation has a design pressure of 1750 psig and a design temperature of 150'F.

In accordanc.: with the requirements of the 1974 Edition, Sunuer 1975 Addenda the hydrostatic test pressure would be 2188 psis (1.25 times design pressucc).

The design configuration of the hydraulle control unit at DFN has a piston with preneure seals that should not have a differential pressure greater than 300 psig to ensure they are not damaged during a test.

This limitation requires nitrogun to bo supplied to the opposite side of the piston within 300 pais of the hydrostatic test pressure. This design also contains a rupture disc which will burst to relievo pressure at 1900 to 2100 psig. At tho hydrostatic test pressure of 2188 psis, the minimum required nitrogen pressure would be 1888 psig which would require the nitrogen tank rupturo disc to be removed and plugged. This high prosauro nitrogen (1888 psig) poses danger to personnol in two ways (1) the nitrogen is pressurizing a system above its normal operating proscuro; and (2) a large quantity of nitrogen is released into the space occupied by tho test personnel when the nitrogen tank rupturo disc is removed.

  • Thero are 185 valves with this number which are denoted by -1 through -185 af ter the flow diagram valvo number.

-rr REQUEST FOR RELIEF H-12 BASIS FOR RELIEF (cont'd)-

If the test pressure is reduced to 1.1 times the design pressure, as allowed by IWC-5222 of the 1977 Edition Winter 1977 Addenda and later codes, the hydrostatic pressure will be reduced to 1925 psis, which allows the nitrogen pressure to be reduced to 1625 psig to maintain the 300 psis pressure differential. This lower nitrogen pressure (1625 psig) does not require the rupture disc to be removed. Therefore, both the lower nitrogen pressure and not removing the rupture disc will (1) reduce the amount of nitrogen released into plant spaces, (2) simplify the procedure, and (3) reduce the chance of injury to personnel or damage to equipment.

For the second 10-year interval, BFN will be updating its code of record for in-service inspection examinations and SPTs from the 1974 Edition, Summer 1975 Addenda to the latest NRC-approved code in accordance with 10 CFR 50.55a(b)(2), which will requiee the system hydrostatic pressure to be 1.1 times the design pressure for systems with design temperature of 200'F or less (IWC-5222).

The next scheduled performance of the CRD Hydrostatic Test would be performed at the lower test pressure (1.1 times design pressuro) rather than the test pressure required by the 1974 Edition, Summer 1975 Addenda (1.25 times design pressure).

For these reasons TVA feois the CRD System hydrostatic test pressuro should be reduced:

to minimize the risk to personnel and equio-ment, simplify test proceduro, and perform an effective pressure test as allowed by later editions of ASME Codes, Based on tho abovo juo. ification, TVA concludoc that a significant doet taso in safety would not result from the proposeo attornate inspection below.

perform CRD system hydrostatic pressure toot ALTERNATE TESTitlC at 1.1 timeo system design proscuro (pd) for 3/4-inch piping betwoon valvos FCV 85-39B* and 85-617* and 1-inch and 1/2-inch piping bolwoon valvos FCV 85-39A*, 85-589*, 85-590*, and the hydraulic accumulatora.

TVA Drawing CRD 47W820-2 REFERENCE

-