_

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE N_O_, NR-8075-D-801-S DATE:

$[p 1 1 ]ggg EAGE: 1 OF 5 DEVICE TYPEi Density Measurement Unit MODEL:

BKG 40823-01 MANUFACTURER / DISTRIBUTOR:

Agfa Corporation

  • Agfa Photo Division Manufacturing 8 Henderson Drive West Caldwell, NJ 07006
  • (Formerly Agfa-Gevaert, Inc.

Peerless Photo Products Division)

SEALED SOURCE MODEL DESIGNATION:

Amersham AMC.16 ISOTOPE:

MAXIMUM ACTIVITY:

Americium-241 110 millicurie.s (4.7 GBq)

LEAK TEST FREOUENCY:

6 Months PRINCIPAL USE:

(D) Gamma Gauge CUSTOM DEVICE:

X YES NO CUSTOM USER:

Agfa Corporation Agfa Photo Division Manufacturing 100 Challenger Road Ridgefield Park, NJ 07060-2105 i

9809220343 980911 i:

PDR RC e

SSD PDR 5

'~

~ -.

k

I I

1 REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO: NR-8075-D-801-S DATE:

SEP lllSH PAGE: 2 OF 5 DEVICE TYPE: Density Measurement Unit DESCRIPTION:

The device is designed to measure the density of a liquid as it flows past the radioactive source and detector.

The gauge is fastened to a pipe by two flanged connectors and is mounted in a fixed location.

The overall dimensions of the device are 8.82" (22.4 cm) wide and 13.32" (33.05 cm) in height.

The materials used to house the components of this device are stainless steel with a steel base plate.

The source capsule is located in a lead cylinder and is covered by a titanium foil, pressure-fitted to the lead with an 0-seal.

The lead cylinder is inserted into a steel cylinder and is bolted to the base plate.

The device is inserted into an emulsion pipe and is secured into place by bolts.

In a photographic film and/or paper production process, it will provide a measurement of the silver concentration of an emulsion.

There are no on/off mechanisms or indicators for the source position, as this source is constantly irradiating the emulsion s

solution through the device.

As of September 18, 1995, Agfa disposed of and no longer possessed this device.

LABELING:

A radiation label with the appropriate information and warnings, as specified by 10 CFR 20.1901 and 10 CFR 20.1904, was fixed to the device by adhesive, so as not to penetrate the shielding of the device.

This label was placed on the device at the facility at the time of arrival from Germany.

DIAGRAM:

See attachment 1.

REGISTRY OF RADIOACTIVE SEALED SOUhCES AND DEVICES SAFETY EVALU3 TION OF DE7 ICE HQ1 NR-8075-D-801-S DATE:

$[p ] ] Iggg PAGE: 3 OF 5 DEVICE TYPE: Density Measurement Unit CONDITIONS OF NORMAL USE:

The environments to which this device is exposed are mildly corrosive.

The device is used as a density meter for the measurement of the silver concentration in photographic emulsion solution.

The emulsion temperature is approximately 100 F (38 C) and has a pH in the range of 5.0 to 6.1. The room temperatur:2 and humidity are typically in the range comfortable to workers.

Personnel may occupy the rooms in which the device is located for a significant part of the work day; however, the device shall be located such that it is not in the immediate vicinity of personnel.

The expected useful life of this device was greater than ten years, which was largely dependent on the electronics.

PROTOTYPE TESTING:

.igfa Corporation did not supply prototype test results regarding mechanical operation (i.e., no specific data on testing of the device). In lieu of such submission, Agfa Corporation referred to the test certificate No. 6.32-3054 issued by the Physiotechnical Federal Institute, a German Agency which states that the construction of the device, Model 40823-01, is approved.

Furthermore, the manufacturer reported that the device has been used in Europe for about 21 years with no reported incidents involving breach of the source or loss of shielding around the device.

EXTERNAL RADIATION LEVELS:

A dose rate on 0.02 mR/hr (0.2 ySv/hr) was measured by the manufacturer at 3.96" (10 cm) from the device.

S

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE I

NO: NR-8075-D-801-S DATE:

SEP 1119H PAGE: 4 OF 5 DEVICE TYPE: Density Measurement Unit i

OUALITY ASSURANCE AND CONTROLS:

The quality control program related to the manufacture and testing of this device involved a series of tests to determine the integrity of the source capsule.

Three tests were specified:

wipe test, bubble test, and immersion test.

Upon arrival at the licensee's facility, the device was required to be inspected.

A comparison to the manufacturer's specification was required to be conducted at that tine.

The device is also required to be inspected for integrity of the shielding, including seams in the device as it relates to radiation safety.

At the time of receipt, Agfa Corporation was further required to conduct a radiation survey and record activity levels at 5, 30, and 100 cm (1.97", 11.81" and 39.37")

from the surface of the device.

LIMITATIONS AND OTHER CONSIDERATIONS OF USE:

  • The custom device was only authorized for use by Agfa Corporation, Agfa Photo Division Manufacturing, 8 Henderson Drive, West Caldwell, NJ.

As of December 28, 1995, Agfa's license for possession and use was terminated. Therefore, as of the date of license termination Agfa is no longer authorized to possess this device.

  • The custom device was required to be leak tested at intervals not to exceed 6 months using techniques capable of detecting 0.005 microcurie (185 Bq) of removable containment.
  • Maintenance of the custom device was require to be performed only by a qualified representative of the manufacturer under Agfa Corporation's specific license.

The custom user was not to perform any maintenance on the device that would expose the source or remove any part of shielding of the device.

  • The registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO: NR-8075-D-801-S DATE:

$EP 11 NSB PAGE: 5 OF 5 DEVICE TYPE: Density Measurement Unit SAFETY ANALYSIS

SUMMARY

The Model BKG 40823-01 density measurement device and source were transferred from Agfa Corporation to Agfa-Gevaert S.A.,

in Spain.

Agfa Corporation's material licensed which authorized possession of the source in this custom device was terminated on December 28, 1995.

As of this date, Agfa is no longer authorized to possess and use this device.

REFERENCES:

The following supporting documents for the Model BKG 40823-01 density measurement unit are hereby incorporated by reference and are made a part of this registry document:

  • Agfa-Gevaert S.A. letters dated April 13, 1987, April 30, 1987, and December 22, 1987, with enclosures thereto.
  • Agfa Corporation's letters dated January 20, 1989, September 29, 1995, and August 6, 1996, with enclosures thereto.

ISSUING AGENCY:

U.S. Nuclear Regulatory Commission DATE:

SEP 111988 REVIEWER:

/

hn W.

Lubinski 7

/

DATE:

SEP 111898 CONCURRENCE:

e 2 5

' S t'e v e n 'L '. ' B a g g e t t

_m..

i i

i l

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES L

' SAFETY EVALUATION OF DEVICE HQ1 NR-8075-D-801-S DATE!

SfP 111988 ATTACHMENT i i

l DEVTCE TYPE! Density Measurement Unit l

?

I Measuring head with flange Measu-irr; head with screw connecter N

I

/

A i

1 l

l.

I I

1 a

l

(

t_

l l

I Packing i

i i

i I

I i

I

- l-

~

ns -

e j

l l

l.

Ionisation' cha mber I

j p ** p " '

. -outer electrode i

I I

r" intermediate electrode i

h.

NI J

inner electrode I

s 4 s L le i

t 4 x cylindrical E

b

-~' **"'

l l

i I

k

['

t I

I

!/ser.w l

M5 x 18

  • +

~"*

5%

'-Yt"

-T-

~

N N I

=.n

.g~

"\\

/

.;'. %",,7 -

R:

R

,=

3 y

\\

/

r.

\\.

ftsfas

/

(

j i

stainless steel

\\

t *

    • I

\\a l

e t'

1, I

0-seal

--)

i i

l 100 micron - J':

J {*

I

,titznium foil

]

g~

g

____a.

l

[ j g

g 3,,,

4 x cylim rical 6

screw MS x H This slit only with air-coolea version Source holder Am*I41 ALL SIZES IN MILLIMETERS All parts in stainless steel f

r l

l

PAGE1_

NRC FORM 667 U. S. NUCLEAR REGULATORY COMMISSION i

j REQUEST FOR A SEALED SOURCE OR i

- DEVICE EVALUATION-INSTRUCT'ONS: Send this request AND a copy of all related letters /applicatxns and drawings to: The Sealed Source Safety Sectkm, ATTN: Chief, OWFN Mall Stop 6 H3. Change the License Tracking System rnliestone to 19 aruf assign to reviewer code I-5.

NOTE: Retain a copy of this request with the application and background files.

RLouCSTE.R REGION / LOCATION:

[pjkh//

[,Joj //fgp li R 11 R lil R IV RV U HQ LFDCB VELEPHONE ' NUMBER DATE TYPE Gr ACTION REQUESTED G%eck as appropriate)

APPLICANT'S NAME SOURCE REVIEW C 68 XENDMENT OF he cae a==^g'o"s"ce' MAIL CONTROL NUMBtAm DEVICE hEVIEW LE'TTER/APPUCAiTIOlNb hL l

ATE UCENSE NUMBERW CUSTOM REVIEW

~ //[ @ ~ [*/~ 8

' ~ p f A 3 ; d :. y o n. Q g

a cwp*WA *'=

chan S"

s

'&d v k u M 0764o 4 /97 FOR SSSS USE ONLY REVIEWEN G3 < 1> W TK0S </62.s-o /

96 - 85~~

f-g NUht NUMBER ASSIGNED DATE RECEIVED DATE ASSIGNED DATE TO FEES

/

TYPE OF ACTION (Indicate the number of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPUCANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (9D)

DEVICE (9B)

NEW NEW NEW NEW d NDMENT AMENDMENT AMENDMENT AMENDMENT s

d NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO FEES REQUIRED NO j OTHER (Spec #y)

TOTAL NUMBER OF NOTES REVIEW HOURS NUMBER OF DEFICIENCY LETTERS NUMBER OF

/

DEFICIENCY CALLS FOR BILLING PURPOSES ONLY NAME CHANGE ADDRESS CHANGE

] NEW REGISTRATION -

] PRODUCT INACTIVE -

ADDTO BILLING REMOVE FROM BtLLING FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY

]9A U 9B BC 90 N

n AMOUNT RECEIV T

CHECK NUMBER MATANN UPDATED q

~ AS REQUIRED DATE oF CHECK

' d,,{ '

LOG /)

(

/ 53Ah j MATSYS UPDATED

( LLg. / h q,

AS REQUIRED A-oVEo.,

-~~e mTE Rn

= TE CLwHENTS l

_