DEVICE TYPE:
Source Exchanger L
MODEL:
C-4 I
Ii MANUFACTURER / DISTRIBUTOR:
Gamma Industries, Inc.
P.O. Box 2543 Baton Rouge, LA 70821 r
i i
i I
i SEAT.FD SOURCE MODEL DESIGNATION:
Various (See Limitations-
[
Paragraph) j
' ISOTOPE:
MAXIMUM ACTIVITY:
'200~ curies (7.4 TBq) j T.FAK TEST FREOUEN Q 6 months i
l i
PRINCIPAL'USE:
(A) Industrial Radiography i
CUSTOM DEVICE:
YES X
NO l
9809220279 990914 t
PDR RC e
g i
SSD PDR g
l
1 REGISTRY:OF RADIOACTIVE SEALED SOURCES AND. DEVICES SAFETY EVALUATION OF DEVICE l
'I i
SEP 14 H88 NO.: NR-300-D-839-S' DATE:
PAGE 2 OF 4
' DEVICE TYPES Source Exchanger i
f DESCRIPTION 5
i The device consists of a lead filled cylinder 11-1/4" (28.58 cm)
-high constructed from a standard section of 8" (20.32 cm)
I schedule.20 steel pipe with a welded 1/4" (6.35 mm) thick steel
{
cover plate,-top and bottom.
The steel enclosed lead cylinder.is j
then' welded to a 1/2" (1.27 cm) x 1/2 " _ (1. 27 cm) - 0.D. x 0.065"
.(1.65 mm) wall stainless steel tubes, bent into 9011 arcs welded j
together and are secured inside'the cylinder.
i The tubing is arranged such that the-two source inlet holes are 180* apart, 3-3/4 "- -(9. 52 cm) from the top?of the cylinder, and i
Ethe blind'end of the arcs are located 5/16" (7.94 mm) off the j
eentral' axis of the cylinder.
The source position is arranged in such a manner that there is always a minimum of 4"-(10.16 cm) of d
lead between the source and the exterior of the device.
l In' order to prevent loss;of'the source, an external threaded boss is welded'to the exterior of the device around the source
.i entrance orifice-.
A' standard _ pipe cap'with a welded "L"
is used j
.to. enclose'the source within.the device.
The cap "L"
has a' slot, which mates with another "L" welded on the device exterior which is alsoLslotted.
'A padlock is placed in the slot to assure that j
the source is not removed by unauthorized personnel.
.j l
LABELING:
i The~ device is. labeled with the appropriate DOT transportation label; and in addition, a label;with the' standard radiation caution symbol 1in' color, specifies the isotope, activity, date of l
calibration, source serialinumber and states " Danger, Do Not
)
Handle,1 Radioactive Material, Notify Gamma Industries, I
' Baton Rouge, Louisiana or Civil Authorities."
1 l
i REGISTRY-OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: 'NR-300-D-839-S DATE:
SEP 141u4 pace 3 Op 4 l
i l
l DEVICE TYpEr Source Exchanger Rai'ERNAL RADIATION LEVELS i
'The source within the device is greater than 4" (10.16~cm) to the outer surface of the. device.
Utilizing the device fully loaded (200 Ci - [7.4' TBq) Ir-192) the following dose rates were obtained l
with a calibrated ionization chamber:
]
Highest Lowest mrem /hr.psv/hr mrem /hr Sv/hr Surface dose rate 45.
450 10 100 Dose rate at 1 m (39.37")
1.5
- 15 0.24 2,4-LIMITATIONS AND/OR'OTHER CONSIDERATIONS OF USE:
i i
Licensing personnel should thoroughly review the licensees
'{
procedures for source exchange using the C-4 source exchanger.
.i Normally only one source is shipped to the licensee, the other
" source port" is used to place the licensee's depleted source for return.
Occasionally, two sources will be shipped if the licensee has an additional device into which he can place the depleted source.
4 The'following " pigtail sources" are the only ones currently being
)
shipped in the C !
i Camerafor Device:
i i
- Budd Models: 40A, 40B, 40AB, 20, 30 and 100 i
Technica1' Operations Models: 412, 490, 498 and 533 Sinco Models: DU-100 and DU-100P' JGamma Industries Model: Century and Model 35 i
i l
l
i "e-s i
3 i
REGISTRY OF RADIOACTIVE: SEALED' SOURCES AND DEVICES l
~
1 SAFETY EVALUATION'OF DEVICE i
4 l
L '.NR-300-D-839-S-DATE:
SEP.)41988 PAGE'4 OF 4 1
DEVICE' TYPE:
Source ~ Exchanger t
'" LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE (Cont'd)-
l
- NOTE:
The factor governing pigtails whichLmay be transported
=i tin.the C-4',
is pigtail length.
Any source manufactured.
l to fit.the'above devices will fit in the C-4 regardless of manufacturer.
)
l SAFETY ANALYSIS
SUMMARY
l i
'The Model"C-4'deviceEis no longer: manufactured or distributed by
.i Gamma' Industries, Inc. and Gamma ~ Industries,.Inc.'is no longer in business.
Therefore,U the registratlori.. certificate -is being j
' converted-to.an.' inactive-registrationicertificate.
- l
~
.i
- The" device was Loiiginally approved ifor licensing purposes by the
'l L Louisia'na' Division'of Ra'diation Control.
NRC attempted to obtain l
~
copies of ~all':'informationLsubmitted.by the registrant in support j
of'the evaluation.s However,.NRC..could not'l'ocat'e'all the
-information. : Therefore,! no? safety evaluation 'of ' the device-was
_-performed as part of the, conversion..of.the' certificate to j
inactive status.
J l
7
~ ISSUING ~ AGENCY-
]
1 LU.S.; Nuclear Regulat'ory Commission
[,
/,'
'i
'SEPl'41998.
+.
Date:
{ Reviewer:
I A'N
~
- dohn W[ Lubinski SIP ! 41998 N 44 #da.-w
- J Date:-
Concurrence:
5Michele L' Burgess
PAGE1 NRC FORM 567 U. S. NUCLEAR REGULATORY COMMISSION REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send tNs request AND a copy of all related letters / applications and draw 6ngs to: The Sealed Source Safety Section, ATTN: Chief, OWFN Mall Stop 6 H3. Change the License Tracking Systern milestone to '9 and assign to reviewer code I-5.
NOTE: Retain a copy of this request with the application and background files.
REQUESTER REGION / LOCATION:
lI C11 C 111 CIV CV C HQ R LFDCB 1ELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as appropriate)
APPUCMI AME SOURCE REVIEW AMENDMENT OF MAN. CONTRdL (JUMBER(S)
- /V / 5 I/y.
REGISTRATION SHEET
) /77 7W
/
NW R(S)
/
DEVICE REVIEW TIONAATE LETTERI UCENSE NUMBCR(S)
CUSTOM REVIEW Y/ b/
i f 0. b 6X 2 5 4'3 sako b cp,LA 7421 FOR 8888 USE ONLY REVEWER MOVDENUMBERSahawl' IUtN ASSGNEDg/$~ W DATE RECEIVED DATE ASSONED DATE TO FEES TYPE OF ACTION (Indicate the nuhnber of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)
SOURCE (9C)
DEVICE (9A)
SOURCE (9D)
DEVICE (9B)
] NEW NEW
] NEW
] NEW AMENDMENT AMENDMENT AMENDMENT AMENDMENT j NO SAFETY EVALUATION REQUlttFD j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (SpecWy)
TOTAL NUMBER OF NOTES REVIEW HOURS g/.-
hd NUMBER OF gMdi,' gshdM IM.
DEFICIENCY LETTERS NUMBER OF
(/
DEFICIENCY CALLS FOR BILLING PURPOSES ONLY j NEW REGISTRATION -
J PRODUCT INACTIVE -
NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY WPE OF FEE FEE CATEGORY b
19A 9B
~
9C 9D AMOUNT RECEIVED CHECK NUMBER MATANN UPDATED 4
~ AS REQUIRED 4p g g sw a = Y;uggTED APPROVED gy
~
DATE RETU4N I
DATE M
b l
COMMENTS e
LA OScool03R,9 SJ19#,ll A IS Ab.
NRC FORM 067 (843)
ORIGINAL.TO SSSS
HP 141sge MEMORANDUM TO:
Sandra Kimberley, License Fee Analyst Office of the Chief Financial Officer FROM:
Seung J. Lee, Mechanical Engineer Material Safety Branch Division of Industrial and Medical Nuclear Safety', NMSS
SUBJECT:
INACTIVE STATUS: GAMMA INDUSTRIES, INC.
ASSIGNMENT NUMBERS 98-44, 98-45, 98-64, & 98-65 We have converted the registration certificates identified in column 1 of the table in the attachment to inactive status and have assigned them the new registration certificate numbers identified in column 2 of the table. If you have any questions, please contact me at 415-5787 or Mr. John Lubinski at 415-7868.
Attachment:
As stated Distribution:
IMNS r/f SSD-98-44, -45, -64, -65 NE01 Registration Certificates listed in Attachment DOCUMENT NAME: C:\\ FILES \\SSDS\\ GAMMA 2.lND n r.c.i
. copy of ini. accum.ni inoic.i. in in. bo.: c - cop 4,inout.it.cnm.ntiencio.ur.
t. copy with.tt chmentiencio u. u - No copy OFFICE IMSB l
IMSB j Q d
l NAME Slee/jl
(,' /
JLubinskj DATE 09/J/fl98 09//q/98 OFFICIAL RECORD COPY "iht)Q)Jou$f Jy C,,, j y y jy 3
e l
u i
GAMMA INDUSTRY, INC. REGISTRATION CERTIFICATES OLD NUMBER NEW NUMBER NR-300-S-101-U NR-300-S-836-S LA-300-S-102-U NR-300-S-837-S LA-300-D-103-U NR-300-D-838-S -
I t
LA-300-D-104-U NR-300-D-839-S LA-300-D-105-U NR-300-D-840-S LA-300-D-106-U NR-300-D-841-S LA-300-S-107-U '
NR-300-S-842-S LA-300-D-108-U NR-300-D-843-S LA-300-D-109-U NR-300-D-844-S LA-300-D-110-U NR-300-D-845-S j
LA-300-D-111-U NR-300-D-846-S LA-300-D-112-U NR-300-D-847-S i
LA-300-D-113-U NR-300-D-848-S i
LA-300-D-114-U NR-300-D-849-S LA-300-D-115-U NR-300-D-850-S LA-300-D-147-S NR-300-D-879-S 1
LA-300-S-148-S NR-300-S-880-S LA-300-S-149-S NR-300-S-881-S -
LA-300-D-150-S NR-300-D-882-S LA-300-S-151-S NR-300-S-883-S 6
LA-300-D-152-S NR-300-D-884-S LA-300-D-153-S NR-300-D-885-S LA-300-D-154-S NR-300-D-886-S LA-300-S-155-S NR-300-S-887-S L
i i
I-ATTACHMENT r
[
n.
.., -