__

W s

.i

},

1

- V t

-REGISTRY OF. RADIOACTIVE, SEALED SOURCES AND DEVICES

. SAFETY EVALUATION OF DEVICE r

,p '

^

NO.:'NR-300-D-886-S.

DATE:

SEP 141988 PAGE 1 OF 5 y

i DEVICE TYPE:

PipewallL Thickness Gaugei

=t MODEL:

Pipeliner"Model 300A 9

i.

MANUFACTURER / DISTRIBUTOR:

Gamma Industries, Inc.

.P.

O. Box 2543

Baton! Rouge, Louisiana 70821-i i

.,I i

SEAT.Rn SOURCE - MODEL DESIGNATION:

Gamma Industries VD(HP)

I l

i ISOTOPE:

MAXIMUM' ACTIVITY:

f

Cesium-137.

20 curies (740 GBq)

Depleted Uranium-Shielding, 11.8 kg (26 lb.)

l s

T.RAK-TEST FREOUENCY 6 months s

PRINCIPAL USE:

(A) Industrial Radiography 1

1 CUSTOM DEVICE:

YES x

NO h-1 i

~ 9909220222 990914 i

PDR RC e

i SSD PDR i

1u 7

4

~

M t

' REGISTRY'OF. RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE'

~

4 i

+

~

(DATE:

SEP-141999 -

-PAGE 2 OF 5:

NO.:'NR-300-D-886'-S' s

'.,* ;1

,_,r

~

' DEVICE TYPE!L PipewalliThic'kness~ Gauge, 7

i 1

DESCRIPTIONr

~

~

The device..is.a=right' circular-cylinder, approximately 5-3/4" (14. 61 ' cm) ' tall ' and 4 -3 /4_" '. (12. 07 cm)- ~ in diameter, with a lock t

. box:attachedi to.one# side and consists.of a depleted uranium shield enclosed ~i'n a' ' stainless steel housing.

The-housing has

~

~

itwo attachingfrings,(one. machined-into thefsurface at the bottom iof the device and_one I inch from the'" top.

The_ top and lock box i

-are heliarc'(TIG): welded tblthe device. :The. cover plate is aluminum and.is bolted to the--device using six 1/4 x 20 x 1 inch

'6~.35 mm'x 50.8'cm x 2.54 cm) bolts.

The cover' plate holds in j

(

' place a= tungsten collimator, which has a 3 /16 " ~ (4. 77. mm) ' diameter I

beam l port.

The depleted uranium shield is a~right circular cylinder with the top taking'a hemispherical ~ dome configuration.

The' shield is

]

4. 3 " ' (10. 92 cm) - in1 diameter by; 4.455" (11.32 cm).in length.

A i

~

snap ring holds the source capsule securely into a tungsten finsert:which has been pressed into a hole centered on the outside

. edge'~of:a 2.407"1(6.11 cm)f diameter' by 1" (2.54 cm) thick depleted ~ uranium wheel.

The source wheel.is rotated by.a l

tungsten. shaft which is.0.375" (9.53' mm)' in diameter at the wheel and LO.5". (1.27 cm) -in diameter at c the locking - mechanism.

The

'wheelfis secured to the' shaft with a Woodruff: key.

i

.The source position is controlled by rotation of the tungsten 1

Ini he shielded position'the source is-180 degrees from rshaft.

t the' cover plate and' oriented towards the dome part of the Edepleted uranium shield.

A plunger-type lock, which has been

[

1 modified by the manufacturer-for this particular application,-is

' incorporated tof ock the source ~in either the'" exposed" or the j

l Jr

" shielded"Jpositions.

The' tungsten shaft is fitted with a lknurlediknob~which.has an arrow engraved to point to the "off"'or

'on" position.

The"off" and "on"' positions are stamped into the front'ofothe lock: box to indicate when-the source is exposed or l

3^

i

", l a

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION 0F. DEVICE NO.: NR-300-D-806-S DATE:

$[p 14 gg PAGE 3 OF 5 DEVICE TYPEr Pipewall-Thickness Gauge DESCRIPTION-(Cont'd)-

shielded.

The sources can be locked in the "on" position so that while the unit is being operated for pipe inspection, the source will remain in a rigid position with no movement of the source to affect the electronic readout.

LABELING:

The device bears.the manufacturer's name plate which specifies that it contains approximately 26 pounds (11.8 kg) of depleted uranium.

The plate also specifies the isotope and the maximum activity permissible.

A second plate is attached to the device which specifies the source manufacturer, model number, serial number, activity, ar.1 date of calibration.

Two other identical labels with the conve.'tional radiatica caution symbol state

" Danger, Do Not Handle - Radioactive Material, Notify Gamma Industries, Baton Rouge, Louisiana, or Civil Authorities."

CONDITIONS OF NORMAL USE:

The device is intended primarily as a source holder to be used in a pipewall thickness gauge.

When used in this manner the operator should receive only. scatter radiation.

The radiation intensity will vary around the inspection machine depending on pipe size, pipe evaluation, material thickness, type and distance of other materials in the area.

The only way to determine the level of scatter radiation is to perform a radiation survey.

After unlocking the device, the source is exposed by manually rotating the control' knob 180 degrees clockwise.

To secure the source, the control' knob is rotated 180 degrees provided for the

" exposed" and " shielded" position.

e

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-300-D-886-S-DATER SEP 141993 PAGE 4-_OF 5 DEVICE TYPE:

Pipewall Thickness Gauge i r EXTERNAL RADIATION LEVELS:

With a 1,500 millicuries (55.5 GBq), Cesium-137 source in the shielded position, a survey was performed using a Gamma:

Industries Model 200 survey meter with external probe and Gamma Industries Tube Model 714, Serial No. 1010.

The meter was calibrated against a 2000 millicuries (74 GBq) Cesium-137 source.

With the source in the shielded position, the highest exposure rate at the surface of the device was 14 mrem /hr (140 pSv/hr).

The manufacturer also supplied-a radiation profile which indicated that the maximum exposure rate at'6" (15.24 cm) was 2 mrem /hr (20 pSv/hr) and the maximum exposure rate at 1 meter (39.37") was less than 1 mrem /hr (10 pSv/hr).

LIMITATIONS AND/OR OTHER CON'IDERATIONS OF USE:

S The' manufacturer. furnishes operating instructions which include

~

step-by-step instructions for using the Pipeliner Model 300A, and l

. step-by-step instructions for periodic ma'intenance of the device.

The license should include provisions for 26 pounds (11.8 kg) of depleted uranium.

This device shall be[ distributed only to persons with a specific 2,

license: issued by an Agreement State or the U.S. NRC.

It should be'noted that there are no procedures for source

~

exchange by the licensee.

The device must be returned to a source supplier for source exchange.

o l

The manufacturer has performed Type B package tests on this i

device which are being submitted to the DOT for a certificate of compliance.

However, prior to issuance of a certificate of compliance,- only Type A quantities are being shipped.

1 1

I o

^

1 E

i-l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE l

i NO.: NR-300-D-886-SI DATEi SEP 14ItN.

'PAGE'S OF 5

~

DEVICE TYPE
Pipewall Thickness Gauge 1 l

- SAFETY EVALUATIONi

[The Pipeliner Model 300A is no' longer manufactured $or distributed

- by1 Gamma ~ Industries, Inc'Tand Gamma Industries, Inc. is noylonger in busin'ss. 'Therefore, the registration certificate is being-l e

-converted to an-l inactive. registration certificate.

'i l

The. device was originally approvedJfor licensing purposes'by the

- Louisiana-Division of Radiation Control.

NRC attempted to obtain copies of all information? submitted by the registrant in support

-i of the. evaluation.

However, NRC could not locate all the j

!information. 'Therefore,~ no safety' evaluation of the device was

-l

- performed as.part of'the conversion of the certificate to 1

inactive' status.

i

REFERENCES:

Gamma: Industries-Inc.' summary data sheet. submitted by A. R.

Patterson, Jr. and dated March 24, 1986.

?

ISSUING' AGENCY i

U.S.-Nuclear Regulatory Commission i

e 1Dat.e:t SEP 'l 41998 Reviewer.

~

.-[ohnW Lubinski g

" SEP 14 Ine :

'Date:

. Concurrence:

Md%A

~*

Michele L. Burgess i

l

+

y"

.r 4

e

~ _,

NRKFORM 567 PAGE1 0 431 U. S. NUCLEAR REOULATORY COMMISSION REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send thle request AND a copy of all related letters /w. and drh /,r,y. to: The Seeled Source Safety Sec OWFN Mail Stop 6 H3. Change the Ucense Tracidng System milestone to 19 and assign to reviewer code I-5.

NOTE: Retain a copy of thle request with the applicatson and background flies.

t REMSTER

) //$f'/7/./7

' lgYk///

/,7) 1 ll D lli D IV DV D HQ D LFDCB REGION / LOCATION:

TELETHONENUMBER DArE TYPE OF ACTION REQUESTED (Check as,4; ;-)

APPUCANT*8 NAME SOURCE REVIEW AMENDMENT OF REGISTRATION 3HEET uAa. CONTROL NUMBER (5)

DEVICE REVIEW NUMBER (S)

LETTER /APPUCATON DATE UCENSE NUMBER (s)

CUSTOM REVIEW

/ /(? 4 / ' / d/

  • " * " * " f(L77C %t L,h D d /J d 5 U.Adi / 8 'C.

Po. by.J543

/h2 25y) f0'u},

M l

FOR SSSS USE ONLY REvewER uooEt w,msERs NUMeER A88GNED ll/7} 1. r iAs V ?~ N Y DATE RECEIVEDK / hfX DATE A38GNED DATE TO FEES b' O Y

TYPE OF ACTION (Indicate the tAsnber of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (98)

{NEW

~

~

NEW NEW

] NCW AMENDMENT hAMENDMENT AMENDMENT AMENDMENT j NO SAFETY EVALUATION REQUIRED j UCENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Sper#f)

TOTAL NUMBER OF NOTES REVIEW HOURS j ) J,7 M/

g r

NUMBER OF 4

DEFICIENCY LETTERS

///$ d/MO NUMBER OF DEFIC!ENCY CALLS FOR BILLING PURPOSES ONLY NAME CHANGE ADDRESS CHANGE EW REGISMON -

J MODUCNN-i ADD TO BILUNG REMOVE FROM BILUNG FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY

[_

79A D 98 9C 90

)

~

[

AMOUNT f,ECOVED f

V CHECK NUMBER 1 V-,

l MATANN UPDATED AS REQUIRED DATE OF CHECK Q,((

LOG

/ /I.5 h*<.0 j MATSYS UPDATED AS REQUIRED

-.V r

g yy y

~n

~

petc FORM Se7 (543)

Y ononou.To asas

7 SEP 141888 MEMORANDUM TO:

Sandra Kimberley, License Fee Analyst Office of the Chief Financial Officer FROM:

Seung J. Lee, Mechanical Engineer Material Safety Branch Division of Industrial and Medical Nuclear Safety, NMSS

SUBJECT:

INACTIVE STATUS: GAMMA INDUSTRIES, INC.

ASSIGNMENT NUMBERS 98-44, 984 5, 98-64, & 98-65 We have converted the registration certificates identified in column 1 of the table in the attachment to inactive status and have assigned them the new registration certificate numbers identified in column 2 of the table. If you have any questions, please contact me at 415-5787 or Mr. John Lubinski at 415-7868.

Attachment:

As stated

)

I i

Distribution:

1 IMNS r/f SSD-98-44, -45, -64, -65 NE01 Registration Certificates listed in Attachment DOCUMENT NAME: C:\\ FILES \\SSDS\\ GAMMA 2.IND n,.c

. copy or ini. 4.com.ni. inoic.t. in in. no.: c =_co,4,tnout.et.cnm.nte.nclosur.

  • E' = Copy witn.tt.cnmentlenclosur.
  • N* = No copy OFFICE IMSB IMSB j d d

l l

NAME SLee/jl

( //

JLubinsilj DATE 09/)/fl98 09//4/98 OFFICIAL RECORD COPY i

h

L{[

f GAMMA INDUSTRY, INC. REGISTRATION CERTIFICATES i

f

[

~

OLD NUMBER NEW NUMBER

^

i NR-300-S-101-U NR-300-S-836-S i

LA-300-S-102-U NR-300-S-837-S i

t LA-300-D-103-U NR-300-D-838-S i

LA-300-D-104-U NR-300-D-839-S l

LA-300-D-105-U NR-300-D-840-S l

i LA-300-D-106-U NR-300-D-841-S i

LA-300-S-107-U NR-300-S-842-S :-

LA-300-D-108-U NR-300-D-843-S LA-300-D-109-U NR-300-D-844-S LA-300-D-110-U NR-300-D-845-S I

LA-300-D-111-U NR-300-D-846-S ~

LA-300-D-112-U NR-300-D-847-S LA-300-D-113-U NR-300-D-848-S -

LA-300-D-114-U NR-300-D-849-S '

I LA-300-D-115-U NR-300-D-850-S LA-300-D-147-S NR-300-D-879-S LA-300-S-148-S' NR-300-S-880-S I

LA-300-S-149-S NR-300-8481-S l

l LA-300-D-150-S NR-300-D-882-S t

LA-300-S-151-S' NR-300-S-883-S LA-300-D-152-S NR-300-D-884-S j

LA-300-D-153-S NR-300-D-885-S LA-300-D-154-S NR-300-D-886-S j

LA-300-S-155-S NR-300-S-887-S 9

ATTACHMENT i

l l

.t

.j

..