ES-301 Administrative Topics Outline Form ES-301-1 Facility:

Quad Cities Date of Examination:

3/16/2020 Examination Level: RO SRO Operating Test Number:

ILT 18-1 Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations S, N Verification of RCIC Standby Lineup K/A: 2.1.31 Rating: 4.6 Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup.

Conduct of Operations S, D License Maintenance Requirements K/A: 2.1.4 Rating: 3.3 Knowledge of individual licensed operator responsibilities related to shift staffing, such as medical requirements, no-solo operation, maintenance of active license status, 10CFR 55, etc.

Equipment Control S, N Insert a substitute position for a rod on RWM K/A: 2.2.14 Rating: 3.9 Knowledge of the process for controlling equipment configuration or status.

Radiation Control S, D, P ARM Trip Unit Set Point Check K/A: 2.3.5 Rating: 2.9 Ability to use radiation monitoring systems, such as fixed radiation monitors and alarms, portable instruments, personnel monitoring equipment, etc.

Emergency Plan N/A N/A NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes and Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs and RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1, randomly selected)