REGISTRY OF RADIOACTIVE' SEALED SOURCES AND DEVICES SAFETY-EVALUATION OF DEVICE l
NO.: NR-300-D-849-S-DATE:
SEP 141998 PAGE 1 OF 4
.. e 1
l
.-DEVICE TYPE:
-Radiographic Exposure Device f
.j MODELi 35 SA
)
.e
[
.i MANUFACTURER / DISTRIBUTOR:
Gamma Industries, Inc.
P.O. Box 2543 Baton Rouge, LA 70821 I
4
.2 SEAT.RD SOURCE MODEL DESIGNATION:
Gamma Industries S-16 ISOTOPE:
MAXIMUM-' ACTIVITY:
.35 curies (1,295 GBq)
Depleted' Uranium Shielding, 8 kilograms (18 lb)
T.RAK' TEST FREOUENCYi
'6 months o.
4 4,.
i PRINCIPAL USEt y ' (A) ; Industrial Radiography.
i i
CUSTOM DEVICE:
' T -
YESi X
NO i
g,
.i f
l
,9909220120 980914'~
j FDR' ' RC g
SSD-POR F
v a :.,
-n
d REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATICN OF DEVICE NO.: NR-300-D-849-S DATE: $[p 14198 PAGE 2 OF 4 DEVICE TYPE:
Radiographic Exposure Device DESCRIPTION:
The device consists of a depleted urardum shield and polyurethane 1
filler enclosed in a 1/8" (3.18 mm) circular. steel housing constructed by rolling a right circular cylinder, and arc-welding two circular end pieces.
A zircaloy "S"
tube extends through the device's shielding mass.
At one end is a lock-box through which the source pigtail cable and male half; of the quick disconnect-connect connector protrude.
The lock box is the improved version that is used in the Gamma Century A unit.
The drive cable conduit (up to 25 ' [7.62 m] ) is threaded into the lock box after removing a protective screw cap.
The source conduit. (up to 24'
[7.32 m] ) is attached to a fitting at the opposite end of the "S"
tube by a spring loaded quick disconnecc-connect arrangement after removing a protective screw cap.
The depleted uranium shield (approximately 18 pounds (8 kg]) is secured in position by the two cast steel end pieces and is cushioned on its circumference within the device by polyurethane.
A leather carrying handle is attached to the upper aluminum end piece.
A Teleflex drive cable arrangement with a hand crank is provided for moving the source between the exposed and shielded positions from a remote location.
The source guide tube may be of transparent PVC or the more common opaque neoprene coated steel conduit.
The outside dimensions of the device are 5-1/2" (13.97 cm) diameter by 7-3/8" (18.73 cm) in height.
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-300-D-849-S DATE:
SEP 141998 PAGE 3 OF 4 DEVICE TYPE:
_ Radiographic Exposure Device i
J LA[ ELING :
The device bears a label specifying the use of 18 pounds of depleted uranium shielding and the content of the device including the isotope, the activity, the date of measurement, and the source serial number.
An additional label with the radiation symbol in color states, " DANGER - DO NOT HANDLE - RADIOACTIVE MATERIAL."
EXTERNAL RADIATION LEVELS:
The source within the device is less than 4 inches (10.16 cm) from the device's outer su "
With a 38 curie (1.41 TBq)
Iridium-192 source, radiation 2 vels do not exceed 34 mr/hr at six inches (15.24 cm) from the surface.
LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
The manufacturer furnishes an operating and maintenance manual
/
which includes step-by-step instructions for using the exposure f
device and exchanging sources using the Gamma Industries Model C-4 source changer.
The operating instructions in the manual will not, in themselves, meet the requirements of 10 CFR 34 for operating and emergency procedures.
SAFETY ANALYSTS
SUMMARY
The Model 35 SA device is no longer manufactured or distributed by Gamma Industries, Inc. and Gamma Industries, Inc. is no longer in business.
Therefore, the registration certificate is being converted to.an inactive registration certificate.
3
.I
y REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-300-D-849-S DATE:
SEP 14 leal PAGE 4 OF 4 DEVICE TYPEr Radiographic Exposure Device
' SAFETY ANALYSIS
SUMMARY
-(Cont'd)-
3 The device was. originally approved for. licensing purposes by the Louisiana Division'of Radiation Control.
NRC. attempted to obtain copies of all'information< submitted by,the registrant in support of~the-evaluation..However, NRC.coul'd not, locate'all the
~information'.
Therefore., no safety evaluation of the device was i
performed as part of the conversion of the certificate to i
inactive status.
ISSUING AGENCYr
/[
l l
U.S. Nuclear Regulatory Commission Date:
Reviewer:
//
[JohnW.
Lubinski I
Date:
Concurrence:
"M I
~ fs4 Michele L.
Burges's L
L; i
{.'
h a
t'
-(
~
_. _ _ ~
PAGE1 NRC FORM'567 U. S. NUCLEAR REGULATORY COMMISSION REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCTIONS: Send this request AND a copy of all related letters / applications and drawings to: The Sealed Source Safety Section, ATTN: CNef, OWFN Mail Stop 6 H3. Change the License Tracking System milestone to 19 and assign to reviewer code I-5.
NOTE: Retain a copy of tNs request with the application and back round files.
0 LEQUESTER REGION / LOCATION:
lI U 11 Ill IV UV U HQ R LFDCB TaEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (C,eck as appropriate)
ME SOURCE REVIEW AMENDMENT OF MAIL CONTRdL NUMBER (S)
~ /V/$
/4 I/y,
REGISTRATION SHEET
/97 77/7
/
/
DEVICE REVIEW N MBENS)
LETTERIA TION TE UCENSE NUMBER (S)
CUSTOM REVIEW fb/
' 2 0. / box 2545 En+co loucp,LA lOQl
~
FOR SSSS USE ONLY REVIEWER NUh. RS NUMBER ASSIGNED I
/
V/s7/9x
+'477/9 x T RE. AC-. t e _,., e e,
l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)
SOURCE (9C)
DEVICE (9A)
SOURCE (9D)
DEVICE (98)
NEW NEW NEW NEW
] AMENDMENT
, AMENDMENT AMENDMENT AMENDMENT j NO SAFETY EVALUATION REQUIRED d
LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED
] OTHER (Speavy) j I
f TOTAL NUMBER OF NOTES I
REVIEW HOURS gd hd NUMBER OF
[g M > gsh/M "< l-/f.
DEFICIENCY LETTERS i
f NUMBER OF DEFICIENCY CALLS FOR SILUNG PURPOSES OM.Y
] NAME CHANGE
] ADDRESS CHANGE
] NEW REGISTRATION -
J PRODUCT INACTIVE -
ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY
[
b lM M
E bE AMOUNT RECSVED CHECM NUMeER MATANN UPDATED I
Q 4
- AS REQUIRED rge g g som aggv;ug,ATEo
_ eT
,g N
b
- me.o.N 4
COMMENTS e
1-A O Sc o DI D3ti,SS,L,9 'i, TP,6 A IS L b.
. FORM 7 m h
4 MP 141988 A
MEMORANDUM TO:
Sandra Kimberley, License Fee Analyst Office of the Chief Financial Officer FROM:
Seung J. Lee, Mechanical Engineer Material Safety Branch,
Division of Industrial and Medical Nuclear Safety, NMSS
SUBJECT:
INACTIVE STATUS: GAMMA INDUSTRIES, INC.
ASSIGNMENT NUMBERS 98-44, 98-45, 98-64, & 98-65 We have converted the registration certificates identifed in column 1 of the table in the attachment to inactive status and have assigned them the new registration certificate numbers identified in column 2 of the table. If you have any questions, please contact me at 415-5787 or Mr. John Lubinski at 415-7868.
Attachment:
As stated l
l l
f L
Distribution:
IMNS r/f SSD-98-44, -45, -64, -65 NE01
- Registration Certificates listed in Attachment l.
l l.
DOCUMENT NAME: C:\\ FILES \\SSDS\\ GAMMA 2.lND Ta recehne a copy of this document. Indicate in the boa: 'C' =_Copi $ithout attachment / enclosure
- E" = Copy with attachment / enclosure
- N* = No copy
' OFFICE IMSB l
IMSB j Q ld l
l NAME SLee/jl
(//
JLubins[
DATE 09/)(f98 - ' ' '
09//4/98
[
OFFICIAL RECORD COPY h
4 l[
1 i
,_.1
.a.
~.
GAMMA INDUSTRY, INC. REGISTRATION CERTIFICATES OLD NUMBER NEW NUMBER NR-300-S-101-U NR-300-S-836-S LA-300-S-102-U NR-300-S-837-S LA-300-D-103-U NR-300-D-838-S LA-300-D-104-U NR-300-D-839-S LA-300-D-105-U NR-300-D-840-S LA-300-D-106-U NR-300-D-841-S 3
LA-300-S-107-U NR-300-S-842-S LA-300-D-108-U NR-300-D-843-S LA-300-D-109-U NR-300-D-844-S LA-300-D-110-U NR-300-D-845-S I
l LA-300-D-111-U NR-300-D-846-S LA-300-D-112-U NR-300-D-847-S I
LA-300-D-113-U N R-300-D-848-S
)
i LA-300-D-114-U NR-300-D-849-S LA-300-D-115-U NR-300-D-850-S LA-300-D-147-S NR-300-D-879-S LA-300-S-148-S NR-300-S-880-S LA-300-S-149-S NR-300-S-881-S LA-300-D-150-S NR-300-D-882-3 i
LA-300-S-151-S N R-300-S-88.'J-S LA-300-D-152-S NP-300-D-Pd4-S LA-300-D-153-S NR '000-D-885-S LA-300-D-154-S NR-300-D-886-S LA-300-S-155-S NR-300-S-887-S 1
ATTACHMENT
,