CONSUMERS POWER COMPANY PALISADES PLANT ~
DOCKET NO. 50-255 AMENDMENT TO PROVISIONAL OPERATING LICENSE l
Amendment No. 93 License No. DPR-20 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by Consumers Power Company (the I
licensee) dated January 10, 1986, as supplemented by letter dated January 14, 1986, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter It B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public; and (ii) that such activities will be conducted in compliance with the Comission's regulations;
'D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
PDH P
' 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 3.B. of Provisional Operating License No. DPR-20 is hereby amended to read as follows:
l B.
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 93, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION t/ WA
/L Ashok C. Thadani, Director PWR Project Directorate #8 Division of PWR Licensing-B 4
l
Attachment:
Changes to the Technical Specifications Date of Issuance:
Janua ry 30, 1986 4
f
~
l ATTACHMENT TO LICENSE AMENDMENT NO.93 PROVISIONAL OPERATING LICENSE NO. DPR-20 DOCKET NO. 50-255 l
l l
l Revise Appendix A Technical Specifications by removing the page identified below and insert the enclosed page. The revised page is identified by amendment number and contains marginal lines indicating the areas of change.
REMOVE INSERT 4-73 4-73 t
e i
d.
Hydraulic Snubbers Functional Test Acceptance Criteria The hydraulic snubber functional test shall verify that:
1.
Activation (restraining action) is achieved within the specified range of velocity or acceleration in both tension and compression.
2.
Snubber bleed, or release rate, where required, is within the specified range in compression or tension. For snubbers specifically required to not displace under continuous load, the ability of the snubber to withstand load without displacement shall be verified.
e.
Mechanical Snubbers Functional Test Acceptance Criteria The mechanical snubber functional test shall verify that:
1.
The force that initiates free movement of the snubber rod in either tension or compression is less than the specified maximum drag force (break away friction) which is equal to 2% of the rated load of the snubber.
2.
At vation (restraining action) is achieved within the specified range of velocity or acceleration in both tension and compression.
3.
Snubber release rate, where required, is within the specified range in compression or tension. For snubbers specifically required not to displace under continuous load, the ability of the snubber to withstand load without displacement shall be verified.
f.
Snubber Service Life Monitoring A record of the service life of each snubber, the date at which the designated service life commences and the installation and maintenance records on which the designated service life is based shall be maintained as required by Specification 6.10.2.1.
Concurrent with the first inservice visual inspection and at l
1 east once per 18 months thereafter, the installation and maintenance records for each snubber listed in Tables 3.20.1 and 3.20.2 shall be reviewed to verify that the indicated service life has not been exceeded or will not be exceeded prior to the next scheduled service life review.
If the indicated service life will be exceeded prior to the next scheduled snubber service life review, the snubber service life shall be reevaluated or the snubber shall be replaced or reconditioned so as to extend'its service life beyond the date of the next scheduled service life review. This re-evaluation, replacement or reconditioning shall be indicated in the records.
4-73 Amendment No. 23, 69,93
-