MONTHYEARIR 05000083/19982021998-11-0202 November 1998 Insp Rept 50-083/98-202 on 981006-09.No Violations Noted. Major Areas Inspected:Review of Selected Conditions & Records Since Last Insp & Verification of Corrective Actions Previously Committed to by Licensee IR 05000083/19982011998-10-0101 October 1998 Insp Rept 50-083/98-201 on 980908-10.No Violations Noted. Major Areas Inspected:Review of Selected Conditions & Records Since Last Insp & Review of Respiratory Protection Program IR 05000083/19972011997-09-0909 September 1997 Insp Rept 50-083/97-201 on 970630-0703.No Violations Noted. Major Areas Inspected:Review of Selected Conditions & Records Since Last Insp & Verification of CA Previously Committed to by Licensee ML20135C1961997-02-24024 February 1997 NRC Operator Licensing Exam Rept 50-083/OL-97-01 Including Completed & Graded Tests for Tests Administered on 970210-11.Candidate Passed Exam IR 05000083/19940021994-09-20020 September 1994 Insp Rept 50-083/94-02 on 940906-08.No Violations Noted. Major Areas Inspected:Organization & Staffing,Safety Committee Function,Procedures,Requalification Training,Logs & Records,Reactor Operator,Surveillance & Experiments IR 05000083/19930011993-10-0101 October 1993 Insp Rept 50-083/93-01 on 930914-15.No Violations Noted. Major Areas Inspected:Plans,Procedures & Reviews,Fixed Site Physical Protection of Special Nuclear Matl of Moderate Strategic Significance.Details Withheld (Ref 10CFR2.790) IR 05000083/19900011990-03-19019 March 1990 Insp Rept 50-083/90-01 on 900220-23.No Violations Noted. Major Areas Inspected:Onsite Review of Radiation Protection Program Activities,Including Radiation Controls,Environ Surveillance & Monitoring & Transportation ML20011D9861990-01-0404 January 1990 Notice of Violation from Insp on 891113-16.Violation Noted: Blade Drop Time Check Not Performed within Eight Months After Being Performed on 881205 & Quarterly Scram Checks Not Performed within Four Months After 890221 ML20011D9841989-12-15015 December 1989 Insp Rept 50-083/89-04 on 891113-16.Violations Noted.Major Areas Inspected:Biennial Insp of Class II Research Reactor Operation & Followup of Previous Open Items,Including Health Physics Items IR 05000083/19890021989-11-0606 November 1989 Insp Rept 50-083/89-02 on 890926-27.No Noncompliance Noted. Major Areas Inspected:Plans & Procedures,Rept of Safeguards Events Fixed Site Physical Protection of SNM of Moderate Strategic Significance & Matls Accounting Records & Repts ML20244C4951989-04-0707 April 1989 Notice of Violation from Insp on 880227-0302.Violation Noted:From Jan 1988 - Feb 1989,licensee Surveys Inadequate to Evaluate Extent of Radiation Hazards Present ML20244C4991989-04-0404 April 1989 IR 50-083/89-01 on 890227-0302 & 27.Violations Noted. Major Areas Inspected:Radiation Protection Program Activities,Including Radiation Controls,Environ Surveillance & Monitoring & Licensee Actions Re NRC Info Notices ML20196D5141988-11-10010 November 1988 Exam Rept 50-083/OL-88-02 on 881014.Exam Results:One Reactor Operator Passed Written Test ML20151E6671988-07-0505 July 1988 Exam Rept 50-083/OL-88-01 on 880608-09.Exam Results:Two Candidates Passed Operating Tests & One Candidate Passed Written Exams ML20151E6911988-04-0404 April 1988 Insp Rept 50-083/88-01 on 880314-17.Violations Noted.Major Areas Inspected:Onsite Review of Radiation Protection, Environ Surveillance & Monitoring,Transportation Activities, Enforcement Issues & NRC Info Notices ML20151E6741988-03-0707 March 1988 Notice of Violation from Insp on 880314-17.Violation Noted: Licensee Failed to Conduct Adequate Surveys to Evaluate Extent of Radiation Hazards Present in Liquid & Gaseous Effluents Released from Facility IR 05000083/19870041987-11-10010 November 1987 Insp Rept 50-083/87-04 on 871019-22.No Violations or Deviations Noted.Major Areas Inspected:Biennial Insp of Class II Research Reactors IR 05000083/19870031987-04-23023 April 1987 Partially Withheld Insp Rept 50-083/87-03 on 870406-08 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted. Major Areas Inspected:Nuclear Matl Control & Accounting Procedures,Records & Repts & SNM Physical Inventory ML20205N9891987-03-26026 March 1987 Notice of Violation from Insp on 870209-11.Violations Noted: Licensee Transported Two 55-gallon Drums Containing Licensed Matl Outside Confines of Plant Over Road Accessible to Public & Did Not Comply W/Dot Requirements ML20207T3551987-02-20020 February 1987 Notice of Violation from Insp on 870209-11 ML20207T3621987-02-13013 February 1987 Insp Rept 50-083/87-01 on 870209-11.Violations Noted:Failure to Comply W/Dot Requirements for Transportation of Matls,To Follow Radiation Protection Procedures & to Post Required Documents IR 05000083/19860021986-06-0404 June 1986 Partially Withheld Physical Security Insp Repts 50-083/86-02 & 70-1068/86-02 on 860528-29 (Ref 10CFR2.790 & 73.21).No Violations or Deviations Noted.Major Areas Inspected:Plans & Procedures & Repts of Safeguards Events ML20138C5071986-03-27027 March 1986 Notice of Violation from Insp on 860218-21 ML20138C5111986-03-10010 March 1986 Insp Rept 50-083/86-01 on 860218-21.Violation Noted:Failure to Document Safety Review of Mod to Control Blade Shrouds IR 05000083/19850031985-11-0404 November 1985 Insp Rept 50-083/85-03 on 851009-11.No Violation or Deviation Noted.Major Areas Inspected:Licensee Action on Previous Enforcement Matters & Sticking Safety Control Blade 3 IR 05000083/19850021985-07-0808 July 1985 Safeguards Insp Repts 50-083/85-02 & 70-1068/85-02 on 850624-25.No Violations or Deviations Noted.Major Areas Inspected:Security Plan & Implementing Procedures & Security Organization.Details Withheld (Ref 10CFR2.790) IR 05000083/19810011981-08-0404 August 1981 IE Insp Rept 50-083/81-01 on 810714-17.No Noncompliance Noted.Major Areas Inspected:Organization,Logs,Records, Requalification Training,Surveillances,Experiments,Audit Functions & Procedures PNO-II-80-127, on 800724,reactor Was Being Brought to Power When Area Monitor Alarmed.Caused by Failure to Remove Startup Source.Reactor Manually Tripped & Startup Source Removed1980-07-24024 July 1980 PNO-II-80-127:on 800724,reactor Was Being Brought to Power When Area Monitor Alarmed.Caused by Failure to Remove Startup Source.Reactor Manually Tripped & Startup Source Removed IR 05000083/19800011980-04-0909 April 1980 IE Insp Rept 50-083/80-01 on 800317-20.Noncompliance Noted: Failure to Perform Required Safety Sys Checkout Prior to Startup IR 05000083/19790021979-11-20020 November 1979 IE Insp Rept 50-083/79-02 on 791022-25.Noncompliance Noted: Failure to Make Written Records of Monthly Meetings & Failure to Make Intensive Review of Facility Operations During 1977 IR 05000083/19790011979-05-11011 May 1979 IE Insp Rept 50-083/79-01 on 790427.No Noncompliance Noted. Major Areas Inspected:Security Plans,Protection of SNM, Security Organization,Access Control,Locks,Procedures & Security Program IR 05000083/19780061978-12-26026 December 1978 IE Insp Rept 50-083/78-06 on 781205.No Noncompliance Noted. Major Area Inspected:Emergency Drill Observation ML20147B8171978-08-17017 August 1978 Notice of Violation from Inspec on 780817 ML20151X4781977-08-19019 August 1977 PNO-77-146:flushing of Reactor Bldg Toilet Caused Reactor Scrams Over Past Several Yrs.No Safety Implications Involved & Contrary to Published News Repts,Sys Not Required for Emergency Cooling of Reactor IR 05000083/19770041977-03-0101 March 1977 IE Insp Rept 50-083/77-04 on 770721-22.No Noncompliance Noted.Major Areas Inspected:Security Plan,Sys & Areas,Access Control,Surveillance & Security Program Review ML20054C7471975-04-22022 April 1975 IE Insp Rept 50-083/75-02 on 750324-26.No Noncompliance Noted.Major Areas Inspected:Recordkeeping Sys IR 05000083/19750021975-04-22022 April 1975 IE Insp Repts 50-083/75-02,70-0462/75-01,70-0049/75-01 & 70-1068/75-02 on 750324-26.No Noncompliance Noted.Major Areas Inspected:Procedures,Reactor Thermal Output & Nuclear Matl Depletion & Production 1998-11-02
[Table view] |
Text
.
f pg olv _, 4
)w ;J $
9 j //0 Y 7 ~ / LN
^ h d
PRELIMINARY NOTIFICATION August 19, 1977
_This preliminary notification constitutes EARLY notice of an event of POSSIBLE safety or public interest significance.
The information presented is as initially received without verification or evaluation and is basically all that is known by IE staff as of this date.
Facility:
University of Florida Training Reactor l
Docket No. 50-83 Gainesville, Florida
Subject:
SCRAMS AT TRAINING REACTOR CAUSED BY, TOILET FLUSHING y
The University of Florida Training Reactor is a 100 kw (thermal) Argonaut reactor which periodically conducts various authorized physics experi-ments for educational purposes.
During the experiment to measuro the temperature coefficient of reactivity, secondary cooling water is taken from the city water supply rather than the normal well supply to permit better reactor temperature contro1~.
When city water pressure is low, the flushing of the reactor building toilet causes a further decrease in water pressure which is sensed oy a pressure switch which operates as a low flow sensor. The facility is designed so that operation of this pressure switch will result in a reactor scram. Several scrams of this type have occurred over the past several years. There are no safety implications involved. Contrary to published news reports this system is not required for emergency cooling g
of the reactor.
There has been media interest in this event. There was an article in j
the Washington Post newspaper on August 19, 1977 plus national TV and radio media announcements on August 18, 1977.
Region II does not plan to issue a news release. The State of Florida has been notified.
Region II (Atlanta) became aware of media interest when the Washington Post article was transmitted to Region II on August 19, 1977, by the j
NRC Headquarters Office of Public Affairs.
i
Contact:
LConstable, IE x28019 GKlingler, IE x28019 JSniezek, IE x28019 -
Distribution:
Transmitted H St '/.'/I; Chairman Hendrie Commissioner Bradford Commissioner Kennedy S. J. Chilk, SECY C. C. Kammerer, CA Commissioner Gilinsky (ForDistribution)
Transmitted: MNBB $/7 PBldgYll[
E. Volg
, IE L. V. Gossick, ED0 E. G. Case, NRR Regio
'/ s F S. H. Hanauer, ED0 Ol J. J. Fouchard, PA SSBldgdl1,0 (MAIL)
W. G. Mcdonald, MIPC C. V. Smith, NMSS R. J. McTiernan, 0IA R. G. Ryan, OSP R. Minogue, SD V
O W
H. K. Shapar, ELD PRELIMINARY NOTIFICATION 9809170110 770819 U
PDR I&E PNO-77-146 PDR
.