vr4m P.04/04 n'092-3 TRANSNUCLEAR, INC.

July 10,1998 GuualGeo u.

Mrs. Gloria Bennington Division of Safeguards and Transportation o.- O / yM U.S. Nuclear Regulatory Commission Washington, DC 20555 he:

Transnuclear reference: TNY 98042-D Advance notification for an unport shipment of nuclear material from countries that are not party to the Convention on the Physical Protection of Nuclear Material l

This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment of low strategic significance material from Countries that are not pany to the Convention on the Physical Protection of Nuclear Material.

Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:

73.74(a)(3)(i) Data:

Importer of Record Receiving Facility COGEMA, Inc.

Westinghouse Nuclear Fuels Division i

7401 Wisconsin Avenue 5801 Bluff Road Bethesda, MD 20814 Columbia, SC 29209 301/986-8585 803/776-2610 Shipping Facility Carriers COGEMA Pierrelatte Atlantic Container Lines B.P.16 50 Cragwood Road 26700 Pierrelatte, France So. Plainfield, NJ 07080 33 7550 4000 908/668-5556 Transport Coordinator AND Transnuclear, Inc.

Advanced Distribution Systems Four Skyline Drive 2329 So. Hayden Road I

Hawthorne, NY 10532 Spokane, WA 99224 D

914/347-2345 1-800-756-0223 9809150256 980710 ADOCK07004y6 PDR C

V FOUR SKYLINE DRIVE. HAWTHORNE, NEW YORK 10532-2176

\\

1: C S'70 7etEesONE: 834-347 234s. fax: 934-347-2348 i

m.

....a

@(c)97-3 Page 2 of 2 July 10,1998 TNY 98042-6 73.74(a)(3)(ii) Data: Physical description of shipment:

Seventeen model 30B cylinders inside overpacks containing:

RQ, URANIUM HEXAFLUORIDE, FISSILE (containing more than 1 % U235), 7, UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UF6 weight:

38,709 kgs. Approximate U weight: 26,172 kgs enriched to max. 4.95%. Approximate weight U235: 1,309 kgs 73.74(a)(3)(iii)(iv)(v) Data:

MODE ORIGIN (0), TRANSFER (T),

ROUTE DATE/ TIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&

(A) & DEPARTURE (D) AT DESTINATION (D) POINTS EACH POINT Rail Pierrelatte, FRANCE standard rail (D)

August '/,1998 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> Antwerp, BELGIUM (A) August 10,1998 Ocean.

standard ocean 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> (D)

August 12,1998 Liverpool, ENGLAND (A/D) August 15, 1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Halifax, CANADA (A/D) August 23,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth, NJ (A/D) August 25,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Baltimore, MD (A/D) August 27,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Portsmouth, VA (A)

August 28,1998 0800 - 2359 homs Arnval at the receivmg facility is estunated to be between 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> and 0900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> on September 1 - 4, 1998.