ML20151W146
| ML20151W146 | |
| Person / Time | |
|---|---|
| Site: | 07001426 |
| Issue date: | 07/16/1998 |
| From: | George M TRANSNUCLEAR, INC. |
| To: | Bennington G NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| References | |
| TNY-98067-6, NUDOCS 9809150196 | |
| Download: ML20151W146 (2) | |
Text
' ' - -
g,
,gyg A
7//!)y.
U ON/992(-/
TRANSNUCLEAR, INC.
Mrs. Gloria Bennington July 16,1998 Division of Safeguards and Transportation
{'
U.S.
aclear Regu o Commission f
or;e-o/YE e:
Transnuclear reference: TNY 98067-Auvance notification for an import smprn::: ef nuclear material from countries that are not party to the Convention on the Physical Protection of Nuclear Material This letter constitutes Transnuclear Inc.'s advance notification to the USNRC in compliance with the requirements as outlined in 10 CFR 73.74(a)(1)(2) for an import shipment of low strategic significance material from Countries that are not party to the Convention on the Physical Protection of Nuclear Material.
Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:
73.74(a)(3)(i) Data:
Imponer of Record Receiving Facility l
COGEMA, Inc.
Westinghouse Nuclear Fuels Division 7401 Wisconsin Avenue 5801 Bluff Road Bethesda, MD 20814 Columbia, SC 29209 301/986-8585 803/776-2610 Shipping Facility Carriers COGEMA Pierrelatte Atlantic Container Lines B.P.16 50 Crastwood Road 26700 Pierrelatte, France So. Plam6 eld, NJ 07080 33 7550 4000 908/668-5556 Transpon Coordinator AhT Transnuclear, Inc.
Advanced Distribution Systems Four Skyline Drive S.2329 Hayden Road Hawthorne, NY 10532 Spokane, WA 99204 1
914/347-2345 1-800-756-0223 i
0 9009150196 980716 PDR ADOCK 07001426 C
.+6 FOUR SKYLINE DRIVE = HAWTHORNE, NEW YORK 10532 2176 TELEPHONE: 914-347 2345. FAX: 914-347-2346
/p jM
cm Oh/@7g
~
TNY 98067-6 July 16,1998 Page 2 of 2 73.74(a)(3)(ii) Data: Physical description of shipment:
G. Bennington, USNRC 3 model 30B cylinders inside overpacks cont =ining:
RQ, URANIUM HEXAFLUORIDE, FISSILE (containing more than 1% U235), 7, UN2977, Radioactive Material (U235,U238) solid, UF6. Approximate UF6 weight: 6831 kgs.
Approximate U weight: 4620 kg enriched to max. 4.95%. Approximate weight U235: 229 kg.
73.74(a)(3)(iii)(iv)(v) Data:
MODE ORIGIN (0), TRANSFER (T),
ROUTE DATE/ TIME OF ARRIVAL COUNTRY /ENROUTE(C/E)&
(A) & DEPARTURE (D) AT EACH POINT DESTINATION (D) POINTS Rail Pierrelatte, FRANCE Standard rail (D)
July 30,1998 0800 - 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> Antwerp, BELGIUM Standard ocean (A)
August 4,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Ocean.
(D)
August 5,1998
^n CARTIEA Liverpool, ENGLAND (A/D) August 8,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Halifax, CANADA (A/D) August 16,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Port Elizabeth, NJ (A/D) August 18,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> (A/D) August 20,1998 Baltimore, MD 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> l
Portsmouth, VA (A)
August 21,1998 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> Arrival at the receiving facility is estimated to be between 0700 hours0.0081 days <br />0.194 hours <br />0.00116 weeks <br />2.6635e-4 months <br /> and 1800 hours0.0208 days <br />0.5 hours <br />0.00298 weeks <br />6.849e-4 months <br /> on August 25, 1998.
This shipment will meet the levels of physical protection specified in Appendix E (Annex I).
Yours tmly Transnuclear, Inc.
Mathew George Traffic Coordinator TOTAL P.02
-