Revision 1 d

U,S. NUCLEAR REGULATORY COMMISSION February 1983

@4@ OFFICE OF NUCLEAR REGULATO GUIDE f

%...../

REGULATORY GUIDE 1,150 ULTRASONIC TESTING OF REACTOR VESSEL WELDS DURING PRESERVICE AND INSERVICE EXAMINATIONS A. INTRODUCTION Criterion XVil, "Quality Assurance Records," of Appen-dix B requires,in part, that sufficient records be maintained Criterion 1, "Quality Standards and Records," of Appen-to furnish evidence of activities affectingquality. Consistent dix A, "General Design Cnteria for Nuclear Power Plants,"

with applicable regulatory requirements, the applicant is j

to 10 CFR Part 50, "Domestic Licensing of Production and required to establish such requirements concerning record l

Utilization Facilities," requires, in part, that components retention as duration, location, and assigned responsibility.

important to safety be tested to quality standards commen-surate with the importance of the safety functions to be performed. Where generally recognized codes and standards This guide describes procedures acceptable to the NRC are used, these codes and standards must be evaluated to staff for implementing the above requirements with regard determine their adequncy and sufficiency and must be sur-to the presenice and insenice examinations of reactor plemented or modifi d as necessary to ensure a quality pro-vessel welds in light water-cooled nuclear power plants by e

l duct in keeping with th e required safety function. Criterion 1 ultrasonic testing (UT). De scope of this guide is limited to further requires that a quality assurance program be imple-reactor vessel welds and does not apply to other structures mented in order to provide adequate assurance that these and components such as piping.

components will satisfactonly perform their safety functions D and that appropriate records of the testing of components important to safety be maintained by or under the control B. DISCUSSION of the nuclear power unit licensee throughout the life of the unit Reactor vessels must periodically be volumetrically examined according to Section XI of the ASME Code, Section 50.55a, "Codes and Standards," of 10 CFR which is incorporated by reference, with NRCstaff modifica-Part 50 requires, in part, that structures, systems, and tions,in @ 50.55a ef 10 CFR Part 50. The rules of Section XI components be designed, fabricated, erected, constructed, require a program of examinatiors, testing, and inspections

' ~

tested, and ;nspected to quality standards ccmmensurate to evidence adequate safety. To ensure the continued vith the importance of the safety function to be performed, structural integrity of reactor vessels, it is essential that Section 50.55a further requires that American Society of Haws be reliably detected and evaluated, it is desirable that hfechanical Engineers Boiler and Pressu re Vessel Code results from prior UT examinations be compared to results (ASME B&PV Code) Class I components meet the require-from subsequent examinations so that flaw growth rates ments set forthin Section XI,"Rules for Inservice inspection may be estimated. Lack of reliability of UT examination of Nuclear Power Plant Components," of the ASME Code, results is partly due to the reporting of ambigaous results, such as reporting the length of flaws to be shorter during Cnterion Xil,"Control of hkasuring and Test Equipment,"

subsequent examinations. His lack of reproducibility arises of Appendix B, "Quality Assurance Criteria for Nuclear because the Code requirements are not specific about Power Plants and Fuel Reprocessing Plants," to 10 CFR many essential variablesin the UT procedures. Recommenda-Part 50 requires, in part, that measures be established to tions of his guide provide guidance that would help to ensure that instruments used in activities affecting quality obtain reproducibility of results. Reporting of UTindications are properly controlled, calibrated, and adjusted at specified as recommended in this guide will help to provide a means periods to m aintain accuracy within necessary limits.

for assessing the ambiguity of the reported data.

.~

USNRC REGULATORY GuloES Comments should be sent to the Secretary of the Cornmission, l

U S. Nuclear R egulat ory Commission, Washington, D.C. 205 5 s, j

Regulatory Guides are issued to describe and make available to the Attention: Docketing and Service Oranch, puoHC m et h ons ac c e p t a ble to the NRC staff of implementing specific parts of the Commission's regulations, to delineate tech-The gWdes are issued in the following ten broad divisJons:

niques used by the staff in evaluating specific problems or postu.

B lated acc6 dents, or to provide guldance to apphcants. Regulatory

1. Power Reactors
6. Products Culdes are not substitutes for regulatic.ns, and compliance with
2. Research and Test Reactors
7. Transportation them is not required. Methods and solutions dif ferent from those set 3, Fue!s and Materials Facilities
8. Occupational Health out in the guides will be acceptable if they provide a basis for the
4. Environmental and Siting
9. Antitrust and F6nancial Review far. dings requisite to the issuance or Continuance of a permit or
5. Materials and Plant protection to. General license by the Commission.

Coples of issued guides may be purchased at the current Government This quade was issued af ter consideration of comments received from Printing Office price. A subscription service for future guides in spe-the puuic. Comments and suggestions for improvements in these Clf 6C divisions is available through the Government Printing office, guides are encouraged at all times, and guides will be revised. as information on the subscription service and current GPO prices may appropriate, to accommodate Comments tad to reflect new informe-be obtained by writing the U.S. Nuclear Regulatory Commission, tion or ewerience.

8808230046 830228 "St a-D.C. 20555, Attendon: Publicauons Sales Manager.

__1_5_

__ _f_@ _ _ _ _ _ _ __

% OW @4 O

Operating and licensing experience,2,3 and industry performance characteristics (amplitu de linearity and s

4 tests have indicated that UT procedures that have been amplitude controllinearity)is to be verified at the beginning used for examination of reactor vessel welds may not be of each day of examination. Requirements in Article 4, adequate to consistently detect and reliably characterize Section V,1977 eoition, which is referenced by Section XI, Daws during inservice examination of reactors. This lack of for the periodic check of instrument characteristics (screen reproducibility oflocation and characterization of flaws has height linearity, amplitude control linearity, and beam resulted in the need for additional examinations and spread measurements) for UT examination of reactor evaluations with associated delays in the licensing process.

pressure vessels have been relaxed. De interval between periodic checks has been extended from a period of I day

1. INSTRUMENT SYSTEM PERFORM ANCE CllECKS to a period of extended use or every 3 months, whichever is less. This change has not been justified on the basis of Instrument system performance checks to determine the statistically significant field data. Performance stability of characteristics of the UT system should be performed at automated electronic equipment is dependent on system intervals short enough to permit each UT examination to be performance parameters (essential variables), and the ASME correlated with particular system performance parameters to Code has no quality standards to control these performance help compare results. Dese determinations willhelp makeit parameters. Untd the performance stability of UT systems possible to judge whether differences in observations made can be ensured by the introduction of quality standards, at different times are due to changesin the instrument system it is not reasonable toincrease the period between calibration characteristics or are due to real changes in the Gaw size and checks. Therefore, recommendations have been made to characteristics. Determinations for "Frequency-Amplitude check instrument performance parameters more frequently Curve" and "Pulse Shape" recommended in regulatory posi-than is specified in the ASME Code.

tions 1.4 and 1.5 may be made by the bcensee's examination agent by using any of the common industry methods for Requi aments of Appendix I, Article I,I-4230,Section XI measuring these parameters as long as these methods are of the ASME Code,1974 edition, state:

adequately documented in the examination record. These measurements may be performed in the laboratory before "System calibration shall be checked by verifying the and after each examination, provided the identical equip-distance-amplitude correction curve (I-4420 or I 4520) ment combination (i.e., instrumentation, cable, and search and the sweep range calibration (I-4410 or I-4510) at the unit)is used during the exa nination, start and finish of each examination, with any change in examination personnel, and at least every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during Dese determinations are to aid third-party evaluations m examination."

j when different equipment is used to record indications on subsequent examinations and are not intended to qualify in the 1977 editton, these requirements were changed.

systems for use.

According to Article 4 (T-432.1.2),Section V of the ASME Co'le,1977 edition, the following applies:

The intent of regulatory position 1.5 is to establish the instrumeM palse shape in a way that actualvalues of pulse "A calibration check on atleast one of the basic reflectors length and voltages can be observed on an oscilloscope. The in the basic calibration block or a check using a simulaior calibrated time base does not necessarily have to follow the shall be made at the finish of each examination, every time base of the distance-amplitude correctia)(DAC) curve lut 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during the excmination and when examination may be chosen to suitably characterize the initial pulse.The personnel are changed."

pulse shape record will assist in analyzing potential dif ferences in daw response between succes:ive examinations (i.e.,is the This requirement has several rninor deficiencies, including difference due to flaw growth er system change).

the following:

Pulse shape is best determined by using a high impedance

a. One-Point Check osedloscope with the transducer disconnected from the instrument.

A calibration check is now required on only one of the basic reflectors. As a result, the accuracy of only one point

2. CALIBR ATION on the DAC curve, and not the accuracy cf three points as previously required, is checked. His alteration would According to Appendix 1, Article I, I-4230,Section XI of permit the instrument drift for other metal path distances the ASME Code,1974 edition, instrument calibration for to go unnoticed, which is not desirable.

I"l'ltrasonic Reiaspection of Pugrim i Reactor Vessel Nozzle N 2B," John H. G;eske, NUREG-6502,

b. Secondary Reference 2"Summary llatch Nuclear Plant Unit 1 Reactor Pressure Vessel Herair," 1972, Georgis Power comrany.

ne change allows a one point check by a mecham, cal or electronic simulator instead of a check against the basic 3S u m m ar y of the Detection and Evaluation of Ultrasonic Indicauons. Edwin Hatch Unit i Reactot Pressure Yessel," January calibration block. A mechanical simulator could be a j 1972, Georgia Power Company, plastic, steel, or aluminum block with a single reference

  1. Round robin tests conducted by the Pressure Vessel Research reflector, which may be a hole or a notch.Without specified 8 " '

fhick s ction steet.'

details, the electronic simulator could be any device that 1.150-2

provides an electrical signal. With the resulting uncertainty, dropped) during transport than those parameters that there may be errors in checking against the secondary served as a basis for defining the error band.

reference (simulator), the magnitude of which is undefined and unknown.

Use of electronic simulators would be permissible if they can check the calibration of the UT system as a whole

c. Electronic Simulator and the error band introduced by their use can be relied on and taken into consideration.

Subarticle T-432.1.3 of Article 4,Section V of the ASME Code,1977 edition, allows the use of an electronic

d. Static Versus Dynamic Reflector Responses simulator and also permits the transducer sensitivity to be checked separately. Both these provisions may introduce With some automated systems, the DAC curve is errors that will be very difficult to detect.

manually established, in these cases, the signalis maximized by optimizing the transducer orientation toward the To avoid the introduction of errors and to ensure calibration holes. Subsequently, detection and sizing of repeatability of examinations at a later date, it would be flaws are based on signals received from a moving transducer advisable to check the eJiMation of the entire system where no attempt is made (oritis not possible) to maximize rather than that of individual coraponents. Checking system the signal even for significant flaws. This procedure neglects calibration without the tranWcer and the cable is not several sources of error introduced by the possible variation advisable because these tests do not detect possible' leakage in signal strength caused by:

or resistance changes at the connectors. This is especially important when the UT examination is performed under (1) Differences between the maximized signal conditions of h% humidity or under water and the connec-and the unmaximized signal, tors may not le waterproof or moistureproof. Checking the transducer i e r' n tivity separately (sometimes weeks in (2) Loss in signal strength due to the separation of advance) also neglects the effects of possible damage due to the transducer from the metal surface because transport or use. The transducer characteristics may change of the viscosity of the coupling medium (plan-because of damage to or degradation of internal bonding ing effects).

agents or inadvertent damage to the transducer elemer; Further, the use of it: dectronic block simulator (EBS) as a (3) Variation in contact force and transducer secondary sta ilard introduces an error band in the calibra coupling efficiency.

tion process. Tha error band may depend on, among others, g the following factors:

(4) Loss in signal strength due to structural vibra-tion effects in the mosing transducer mount (1) Drift due to ambient temperature change.

and vther driving mechanisms.

(2) Drift due to high temperature storage, d) Drift due to high humidity storage.

(5) Loss in signal strength due to the tilting caused (4) Drift due to vibration and r. hock loading during by the mounting arrangement in some trans-shipment.

ducer mounts, (5) Degradation of the memory device used to store i

the reference signal infermation due to vibra-Decause of the above,it would be advisable to establish tion, shock, aging, or heat effects.

the DAC curve under the same conditions as those under which scanning is performed to obtain data for detection To ensure stability, computer systems are generally and sizing. It would be acceptable to establish a DAC curve kept in an air conditioned environment; however, EBS by maximizing signal strength during manual scans when systems are not usually kept in a controlled environment.

signals are also maximized for flaw sizing. Ilowever, it would not be advisable to use manually maximized signals 8

Error band for one particular type of instrument to establish the DAC curve when data are obtained later by was determined to be in the range of.M percent. The error mechanized transducers (where signals cannot be maximized) band for other instruments may be in a different range and for the detection and sizing of flaws without adjustment for may vary for the same instrument if memory devices or the potential error introduced. In these situations, an components of different quality are used at a later date, acceptable method would be to establish DACcurves using The error band is dependent on the temperature extremes, moving transducers or to establish correction factors that shock loadmgs, and vibrations suffered by the instrument.

may be used to adjust signal strength. It would be prudent Since the error band value depends on these parameters,it to use care and plarning in establishing correction factors, would be advisable to ensure, through recording instruments, For example, establishing a ratio between a dynamic and that the EBS was not subjected to higher temperatures static mode under laboratory conditions using a precision (container lying in the sun) and greater shock (container transducer drive and stiff mounting may have very little in common with the transducer mounting and traverse condi-tions of the actual examination setup, if correction factors

}

8-calitirsilon vertrication or Ultrasonic rm amination Systems with are to be used, it would be worthwhile to build either

$eNrNo.YcN95$5Nv*[$NuNe'c"trIc c*'r i"

d' full-scale m ekups or consider the variation of all the Service DMsion, P.O. Hox 2 72 8,hittsburgh, PA I s 2b.r'a i/n$'b a; o

important parameters in a suitable model taking into 1.150-3

censideration scalinglaws on variables such as mass, vibration, holes; however, if the block or these holes are polished, this and stiffness constants. It would be advisable toconfirm the fact should be recorded for consideration if a review of the scaling law assumptions and predictions for vibration and UT data becomes necessary at a later date.

viscosity effects before correction factors are used for setting

{

scanning sensitivity levels.

3. NEAR. SURFACE EXAMINATION AND SURFACE RESOLUTION Differences in the curvature and surface finish between calibration blocks and vessel areas could change the dynamic Sound beam at tenuation in any material follows a response, so it may be advisable to estaliish correction factors decaying curve (exponential function); however, in some between dynamic and static responses from the indications cases the reflection from the nearest hole is smaller than the that are found during examination. His would avoid the reflection from a farther hole. This makes it thfficult to difficulties associated with establishing a dynamic response draw a proper DAC curve. In such cases,it may be desirable DAC curve and still take all the factors into consideration.

to use a lower frequency or a smaller transducer for flaw detection near the beam-entry surface to overcome the

e. Secondary D AC difficulty of marginal detectability.

During some manual scans, the end point of the DAC Near-field effects, decay time of pulse reflections, curve may fall below 20 percent of the fuu screen height.

shadow effects, restricted access, and other factors do not When this happens, it is difficult to evaluate flaws on the permit effective examination of certain volume areas in the 20 percent and 50 percent DAC basis in this region since component. To present a clear documentation and record the 20 percent and 50 percent DAC points may be too close of the volume of material that has not been effectively to the baseline. To overcome this difficulty, it is advisable examined, these volume areas need to be identified. Recom-that a secondary DAC curve using a higher gain setting be mendations are provided to best estimate the volume in the developed so that 20 percent and 50 percent DAC points may region of interest that has not been effectively examined, be easily evaluated. For this purpose,it is advisable that the such as volumes of material near each surface (because of gain be increased sufficiently to keep the lowest point of near field effects of the transducer and ring-down effects of the secondary DAC curve above 20 percent of screen height.

the pulse due to the contact surface), volumes near interfaces between cladding and parent metal, and volumes shadowed ne secondary DAC curves need not be generated by laminar Daws.

unicss they are required. If electronic DAC is used and amplitudes are maintained above 20 percent of full screen

4. BEAM PROFILE height, a secondary DAC would not be necessary.

{

f. Component Substitution ducer. It helps to show the three-dimensional distribution of beam strength for comparing results between examinations A calibration check should be made each time a and also for chaeanerizing Haws. De beam profile needs to component is put back into the system to ensure that such be determined and recorded so that comparisons may be components as transducers, pulsers, and receivers were not made with results of successive examinatio is.

damaged while they were in storage. This will ensure elimination of the erros baM and mistakes in resetting the

5. SCANNING WELD METAL INTERFACE various control knobs.

The amount of energy reflected back from a flaw is

g. Calibration lloles dependent on its surface characteristics, orientation, and size. De present AS ' Code procedures rely on the Comparison of results between cumination, performed amplitude of the reflect signal as a basis for judging flaws.

at different times may be facilitated if the same equipment This means that the size estimation of a defect depends on is used and if the reflections from growing flaws can be the proportion of the ultrasonic beam reflected back to the compared to the same reference signal. Reference signals probe, ne reflection behavior of a planar defect, which obtained from a calibration block depend on, among other largely depends on the incident beam angle when a single things, the surface roughness of the block and the renector search unit is used to characterize the flaw,is thus a decisive holes. Therefore, these surfaces should be protected from factor in flaw estimation. The larger the size of a planar corrosion and mechanical damage and also should not be defect, the narrower is the reflected sound beam. The altered by mechanical or chemical means between successive narrow reflected sound beam makes the flaw very difficult examinations. If the reference reflector holes or the block to detect in most cases (unless the beam angle is right).6,7 surface are given a high pohsh by any chemicalor mechanical means, the amplitude' >f the renections obtained from these ieflector holes may be altered. Polishing the hoics or the 6.Probabilitr of Detecting rianar Derectsin Heavy wall welds by block surface is not forbidden by the ASME Code, flowever, IJ1trasonle Techniques According to Existing Codes," Dr.Ing. Hans-this possibly altered ampbtude could af fect the sizing of hur*n' berg Yt s'.'

indications found during any examination. At this time,no l

7 i\\

tNg

.k.1

) e recommendations are being made to control the surface Q',Re c,tn tal r

ene oar,

9 roughness of the block or the above-mentioned reflector Number RD 18/N4115.

1.150-4

s Therefore, the beam angles used to scan welds should be has to be considered in judging the significance of flaws.s optimized and should be based on the geometry of thc It is therefore recommended that only signals with a total celd/ parent metal interface. At least one of these angles transducer travel movement greater than the beam spread should be such that the beam is almost perpendicular ( 15 should be considered signiricant.

degrees to the perpendicular) to the weld / parent-metal interface, unless it can be demonstrated that large (Code-

7. REPORTING OF RESULTS unacceptable) planar flaws unfavorably oriented, parallel to the weld-metal interface, can be detected by the UT tech-This guide gives recommendations for recording the charac-nique being used. In vessel construction, some weld preps are teristics of the UT examination system. This information (ssentially at right angles to the metal surface. In these cases, can be of significance in later analysis for determining the use of shear wave angles close to n cegfLTs is not recom-location, dimensions, orientation, and growth rate of flaws.

mended. Two factors would make the use of shear wave angles close to 75 degrees inadvisable,- first, the test distances Records pertaining to UT examinations should be con-I necessary become too large resulting in loss of signal, and sidered quality assurance records. Recommendations on the second, the generation of surface waves tends to confuse collection, storage, and maintenance of these records are the interpretation of results. In these cases,use of elternative given in Regulatory Guide 1.88, "Collection, Storage, and volumetric nondestructive examination (NDE) techniques, Maintenance of Nuclear Power Plant Quality Assurance Re-as permitted by Subarticle IWA 2240,Section XI of the cords." Availability of these records at a later date will permit ASME Code, should be considered. Alternative NDE a review of the UT results from the data gathered during techniques to be considered may include high-intensity previous ultrasonic examinations.

radiograph or tandem-probe ultrasonic examination of the weld-metal interface. To avoid the possibility of missing When ultrasonic examination is performed, certain vol-large flaws, particularly those that have an unfavorable umes of material such as the following are not effectively orientation,it is desirable that the back teflection amplitude, examined:

while scanning with a straight beam, be monitored over the entire volume of the weld and adjacent base metal. Any

a. Material volume near the front surface because of near-area where a reduction of the normal back-surface reflection field effects, cladding disturbance,or electronic gating, amplitude exceeds 50 percent should be examined by angle beams in increments of 15 degrees until the reduction of
b. Material volume near the surface because cf surface I

is explained. Where this additional angle beam roughness or unfavorable flaw orientations.

D signal examination is not practical,it may be advisable to consider examining the weld by a supplementary volumetric NDE

c. Volumes shadowed by insulation or part geometry, technique.

In some cases, as much as 1 inch (25.4 mm) or more

6. SIZINC below the surface is not examined because of the electronic gate setting. This means that the unexamined volume may The depth or throu;h wall dimension of flaws is more contain flaws that would be unacceptable according to significant than the length dimension, according to fracture Section XI, ASME Code, as follows:

mechanics analysis criteria. Using the single probe pulse-echo technhae, it is possible, depending on flaw orientation,

a. Without evaluation (deeper than approximately 0.2 that some large flaws may not reflect much enery to the inch).

search unit.6 Because of this possibility, the depth dimen-sion of the flaw should be conservatively sized unless there is

b. Even after evaluation (deeper than approximately evidence to prove that the flaw orientation is at right angles 0.85 inch).

l to the be am. It is recommended that indications that are asso-cisted with through thickness flaws and do not meet Code-Assuming an aspect ratio of 0.1, according to IWB-3510.1, allowable criteria or criteria recommended in this guide be Section XI, ASME Code, flaws 0.2 inch deep would be sized at 20 percent DAC as well as at 50 percent DAC.

unacceptable for a 9-inch wall thickness.

in certain cases, it is possible for various reasons that a Typically a BWR reactor pressure vessel (RPV) wallin flaw would not reflect enough energy to the search unit to the beltline region is 6 inches thick and a PWR RPV wallis i

make the indication height 50 percent of the DAC curve 8.5 inches thick. During flaw evaluation, where the wall height. Ilowever, if such a flaw were large, a persistent temperature is high and the available toughness is high, and signal could be obtained over a large area. It is therefore the calculated critical surface flaw depth (a ) exceeds the wall l

c is taken' as the wall thickness. According to thickness (t), a{ ion XI, the allowable end-of-life size recommended that all continuous signals that are 20 percent I

of DAC with transducer travel movement of more than IWB-3600, Sec 1 inch plus the beant spread (as defined in Article 4, non-0.la. Flaws exceeding this allowable value, which would c

D mandatory Appendix D,Section V of the ASME Code, 1977 edition) should be considered significant and should 8"t3trasanle Examination C arism ct!Micatkn ard Actual Rm in RPV," Ishl Kawajima itartma ndustries Co. Ltd.. January 1976.

be recorded and investigated further. The beam spread effect in some cases can make very small flaws appear to be 9.nu Evabation Prtcedures: ASME Section XI EPRI,'NP 719-SP.

large when judged at 20 percent DAC; hence, beam spread speciai report. August 1978.

1.150-5

l r

l be 0.85 inch for a PWR and 0.65 inch for a BWR, will have 1.3 Amplitude Control Linearity to be repaired. De above example illustrates the importance j

of blanking out the electronic indication signals and not Amplitude controllinearity shculd be determined according examining the surface volume to a depth of 1 inch. Since to the mandatory Appendix II of Article 4,Section V of the the flaws that can be missed because of electronic gating may ASN!E Code,1977 edition, within the time limits specified in be larger than the flaws permitted with or without evaluation, regulatory position 1.1.

this unexamined volu rne is important and needs to be identified, in certain specific cases, areas were not examined 1.4 Frequency. Amplitude Curve because insulation was in the way and the transducer could not scan the volume of interest. NRC was not informed of A photographic record of the frequency-amplitude curve this situation until much later. In view of the above and to should be obtained. This record should be available for avoid licensing delays, it is advisable that the volume of areas comparison at the inspection site for the next two successive not examined for any or allof the above reasons be reported, inspections of the same volume. The reDector used in generating the frequency-amplitude curves as well as the The volumes of material that are not effectively examined electronic system (i.e., the basic ultrasonic instrument, depend on the particular part geometry and unique situa-gating, form of gated signal, and spectrum analysis equip-tions associated with each RPV. During identification of ment) and how it is used to capture the frequency-amplitude the material volumes that have not been examined, considera-information should be documented.

tion should be given to the types of Daws that are currently being reported in some of the operating plants. These include stress corrosion cracks in the heat-affected zone, 1.5 Pulse Shape fatigue cracks, and cracks that are close to the surface and sometimes penetrate the surface. Dese volumes of A phatographic record of the unloaded initial pulse rnatenal should be identified and reported to NRC along against a calibrated time base should be obtained. The time with the report of welding and material defectsin acconlance base.nd 'oltage values should be identified and recorded with the recommendation of regulatory position 2.a(3) of on the horizontaland verticalaxis of the above photographic Regulatory Guide 1.16. "Reporting of Operating Informa-record of the initial pulse. De method used in obtaining tion-Appendix A Technical Specifications."

the pulse shape photograph, including the test point at which it is obtained, should be documented.

C. REGULAlORY POSITION

2. CALIBRATION Ultrasonic examination of reactor vessel welds should be performed according to the requirements of Section XI of System calibration should be ch(cked to verify the DAC the ASME B&PV Code,as eferenced m the Safety Analysis curve and the sweep range calibration per nonmandatory Report (SAR) and its amendments, supplemented by the Appendix B, Article 4,Section V of the ASME Code, as a following:

minimum, before and after each RPV examination (or each week in wnkh it is in use, whichever is less)or each time any

1. INSTRUMENT PERFORMANCE CilECKS component (e.g., transducer, cable, connector, pulser, or receiver)in the examination spton is changed. %here possible, ne checks described in paragraphs 1.2 through 1.5 should the same calibration blosk should be used for successive in-be made for any UT sy stem used for the recording and sizing service examinations of the same RPV. De calibration side of reDectors in accordance with regulatory position 6 and holes in the basic calibratim block and the block surfaceshould for reflectors that exceed the Code-allowable criteria.

be protected so that their characteristics do not change during storage. These side holes or the block surface should not oc modified in any way (e.g., by polishing) between successive 1.1 Frequency of Checks examinations. If the block surface or the calibration reflector holes have been polished by any chemical or mechanical means, As a minimu:r., these checks should be serified within 1 day this fact should be recorded.

be fore and within 1 day af ter examining all the welds that need to be examined in a reacter pressure vessel during one outage.

Pulse shape and noise suppression controls should remain at 2.1 Calibration for Manual Scanning the same setting during examination and calibration.

For manual scanning for the sizing of flaws, static calibra-1.2 Screen lleight Linearity tion r.tay be used if sizing is performed using a static trans-ducer. When signals are maximized during calibration, they Screen height linearity of the ultrasonic instrument should also be maximized during sizing. For manual scanning should be determined according to the mandatory Appen-for the detection of flaws, reference hole detection should be

{

dix ! to Article 4,Section V of the ASME Code, within the shown at scanning speed and detection level set accordingly time limits specified in regulatory position 1.1.

(from the dynamic DAC).

1.150-6

2.2 Cahi; ration for Mechanized Scanning

d. When a universal calibration block is used and some or all of the reference holes are larger than the reflector When flaw detection and sizing are to be done by holes at comparable depths recommended by Article 4, Sec-mechanized equipment, the calibration should be performed tion V, of the ASME Code,1980 edition,a correction factor v using the following guidelines:

should be used to adjust the OAC level to compensate for the larger reflector holes. Also,if the reactor pressure vessel

a. Cahbration speed should be at or higher than the has been previously examined by using a conventional block, scanning speed.

a ratio between the DAC curves obtained from the two blocks should be noted (for reference) with the significant

b. The direction of trartsducer movement during calibra-indications data.

tion should be the same as the direction dunng scanning unless (1)it can be show n that the change in scanning direction

3. NEAR SURFACE EXAMINATION AND SURFACE dc.cs not make a difference in the sensitivity and vibration RESOLUTION background noise received from the scarch unit or (2) these dif ferences are taken into account by a correction factor.

The capability to effectively detect defects riear the front and back surfaces of the actual component snould be

c. For mechanued seanning, signals should not be estimated. The results should be reported with the report of maximized during the establishment of the DAC curve.

abnormal degradation of reactor pressure boundary in accordance with the recommendation of regulatory posi-

d. One of the following alternative guidelines should be tion 2.a(3) of Regulatory Guide 1.16. In determining this followed for establishing the DAC curve:

capability, the effect of the following factors should also be considered:

(1) The DAC curve should be established using a moung transduser mounted on the mechanism that will be

a. If an electronic gate is used, the time of start and stop used for examination of the component, of the control points of the electronic gate should be related to the volume of material near each surface that is (2) Correction factors between dynamic and static not being cxamined, response should be established using full-scale rnockups.
b. The decay time, in terms of metal path distance, of (3) Correction factors should be established using the initial pulse and of the pulse reflections at the front and models and taking scaling factcrsinto consideration (assu med back surface should be considered, scaling relatieruhip should be verified).
c. The disturbance created by the clad-weld-metal (4) Correction facion between dynamic and static interface with the parent metal at the front or the back response should be established from the indications that are surface should be related to the volume of material near the found during examination for sizing. For detection of flaws interface that is not being examined, during the initial scan, correction factors may be assumed based on engineering judgment. If assurned correction
d. The disturbance created by front and back metal factors are used for detection, these factors should later be surface roughness should be related to the volume of confirmed on indications from flaws in the vessel during the material near each surface that is not being examined.

examination. Deviation from the assumed salue may suggest reexamining the data.

4. BEAM PROFILE 2.3 Calibration Checks The beam profile should be determined if any recordable flaws are detected. This should be done for each search unis if an EDS is used for ulibration check, the following used during the examination by a procedure similar to that should apply:

outlined in the nonmandatory Appendix B(B 60), Article 4,Section V of the ASME Code,1980 edition, for determining

a. The significant DAC percentage level used for the beam spread. Beam profile curves should be determined for detection and sizmg of indications should be reduced to each of the holes in the basic calibration block. Interpola-take into account the nuimm error that could be introduced tion may be used to obtain beam profile correction for assess-in th sy > tem h> the vanation of resistance or leakage in ing flaws at intermediate depths for which the beam profile the connectors or other causes.

has not been determined.

b. Calibration checks should be performed on the
5. SCANNING WELD. METAL INTERFACE complete connected system (e.g., transducer and cables should not be checked separately).

The beam angles used to scan welds should be based on the geometry of the weld / parent metal interface. At least D vcriables such as temperature, sibration, and shock limits

c. Measures should be taken to ensure that the different one of these angles should be such that the beam is almost perpendicular (115 degrees to the perpendicular) to the

)

for which the EBS error band is determined are not exceeded weld / parent-metal interface unless it can be demonstrated during transport, use, storage, etc.

that unfavorably oriented planar flaws can be detected by 1.150-7

I the UT techmque being used. Otherwise, use of alternative

7. REPORTING OF RESULTS volumetric NDE techniques, as permitted by the AShlE 30 Code, should be considered. Alternative NDE techniques Records obtained while following the recommendations may be considered to include high-intensity radiography or of regulatory positions 1.2,3, 5, and 6, along with discus-tandem-probe ultrasonic examination of the weld-metal sions and exp'anations, if any, should be kept availabla at interface.

the site for examination by the NRC staff. If the size of an indication, as determined in regulatory positions 6.1 or 6.2, equals or exceeds the allowable limits of Section XI of

6. SIZING the AShf E Code, the indications should be reported as abnormal degradation of reactor pressure tuundary in Indications from geometric sources need not be recorded.

accordance with the recommendation of regulatory posi-tion 2.a(3)of Regulatory Guide 1.16.

6.1 Traveling Indications Along with the report of ultrasonic examination test results, the following information should also be included:

Indications that travel on the horizontal baseline of the scope for a distance greater than indications from the a, ne best estimate of the error band in sizing the flaws calibration holes (at 20 percent DAC amplitude) should be and the basis for this estimate should be given.

recorded. Indications that travel should be recorded and sized at 20 percent DAC. Where the indication is sized at

b. He best estimate of the portion of the volu;ne 20 percent DAC, this size may be corrected by subtracting required to be examined by the AShtE Code that has not for the beam width in the though-thickness direction been effectively examined such as volumes of material near obtained from the calibration ho e (between 20 percent each surface because of near-field or other effects, volumes DAC points) that is at a depth sirrClar to the flaw depth. If near interfaces between cladding and parent metal, volumes the indication exceeds 50 perceu DAC, the size should be shadowed by laminar material defects, volumes shadowed recorded by measuring the distance between 50 percent by part geometry, volumes inaccessible to the transducer, DAC levels without using the beam width correction. De volumes affected by electronic gating, and volumes near the determined size should be the larger of the two.

surface opposite the transducer.3 3

c. ihe material volume that has not been effectively 6.2 Nontraveling Indications v.anined by the ust e,f the above procedures may be examined by alternative effective volumetric NDE techniques.

Nontraveling indications above 20 pucent DAC level If one of these alternative NDE techniques is a variation of that persist for a scanning distance of more than 1 inch plus UT, recommendations of regubtery positions 1 and 3 the beam spread between 20 percent DAC poirts (as should wply, A dstiption of the techniques used should defined by nor: mandatory Appendix B, Article 4,Section V be ht:suded in the report. If other volumetric techniques or of the AShlE Code,1977 edition) should be considered variations of UT are used as indicated in regulatory posi-significant. The site of these flaws should be determined by tion 5, the effectiveness of these techniques should be measuring the distance between points at 50 percent demonstrated and the proce.9tes reported for review by DAC and between points at 20 percent DAC where the the NRC staff.

beam width correction is made only for the 20 percent DAC size. De recorded size of the flaw would be the larger

8. ALTERNATIVE hlETilOD of the two determinations. lf it can be adequately demon-strated that a nontraveling indication is from a geometric Appendix A contains an alternative method that is pre-source und not a flaw), there is no need to record that sented in Oapter 3 of the document "Recommended indication.

Changes to Regulatory Guide 1.150," prepared by the Ad lloc Committee of the Electric Utility Industry and pre-sented to the NRC in August 1982.12 he NRC staff has ne following information should also be recorded for evaluated this method and has found it to be an accept.

indications that are reportable accorJ ' to this regulatory able alternative to that presented in paragraphs I through position:

7 of this regulatory position.

10 idance in this document related to information collec-Any I

a. Indications should be recorded at scan interials no tion acti[ies has been cleared under OMB Clearance No. 315o-0011.

I grester than one-fourth inch, g3 It should be noted that the licensee is requ;ted to ap y for relief from impractical ASME Code requirements according to So.5 5a of 10 CFR. If the ticensee is committed to examine a wel as per the not be tnet1

b. He recorded information should include the indica-f,'fn'dmen whe the co rni ent.sr a i e i tion travel (metal path length) and the transducer position 32 for 10 percent, 20 percent. 50 percent, and 100 percent This document is available through Mr. Larr7' Becker, c/o J. A.
  • ^

DAC and the maxirnum amplitude of the signal, haNn72N21.

l 1.150-8

D, IMPLEMENTATION examination programs of all reactors under construction performed after January 15,1982.

Except in those cases in which an applicant proposes an acceptable alternative method for complying with specified The recomm:ndations of this guide are not inter ded to portions of the Commission's regulations, the method apply to prese rvice examinations that have :! ready been described herein will be used in the evaluation of (1) completed. T.te NRC staff intends to recommend that all the results ofinservice examination programs of all operating licensees trodify their technical specifications to make l

reactors af ter July 15,1981, and(2)the resultsof preservice them conratent with the recommendations contained herein.

1 1

D D

1.150-9

APPENDIX A ALTERNATIVE METHOD h f U wing is reprinted with permission from 1.1 Pre-0A5m Performance Checks Chapter 3 of the document "Recommended Changes to Regulatory Guide 1.150," prepared by the Ad lloc Committee of the Electric Utility Industry.

a.

Frequency of checks These checks should be verified Ultrasonic examination of reactor within six months before reactor pressure vessel welds should be performed vessel examinadons pMomed Mng one according to the requirements of outage.

Pulse shape and noise Section XI of the ASME B&PV Code as suppression controls should remain at the referenced in the Safety Analysis same settings during calibration and exa-Report (SAR) and its amendments, mination.

supplemented by the following:

1.

INSPECTI0ft SYSTEM PERFORMAtiCE CHECKS A record of the RF (radiofre-quency) pulse waveform from a reference The conduct of a quality exami-reflector should be obtained for each nation requires that the performance search unit used in the examination characteristics of the inspection in a manner which will provide frequency system used be well defined and amplitude information.

At the highest docum?nted.

This is particularly amplitude portion of the beam, the RF true for situations which requi.e return signal should be recorded before comparisons of examination results it has been rectified or conditioned generated n,uring successive for display.

The reflector used in examinations on the same components.

generating the RF return signal as well as the electronic system (i.e.,

A system comprises:

the basic ultrasonic instrument, a.

a transducer; gating, and form of gated signal) b.

a single channel instrument should be documented. These records or each channel of a multi-channel should be used for comparison with instrument; and previous and future records, c.

a given cable type and length.

1.2 Field Performance Checks l

The checks described in paragraphs a.

Frequency of Checks 1.1 and 1.2 should be made for any UT sfstem,used for inspection of reactor As a minimum, these checks pressure vessel (RPV) welds.

should be verified on-site before and after examining all The field performance checks the welds that need to be described in 1.2 (with the possible examined in a reactor pressure exception of 1.2.c.) should be conducted vessel during one outage.

Pulse on a basic calibration block that shape and noise suppression controls represents the thickness range to should remain at the same setting be examined.

during examination and calibration.

8 1.150-10 l

b.

Instrument Sensitivity during in nonmandatory Appendix B-60, Linearity Checks Article 4,Section V of the ASME Q

Code or Appendix I to Section XI of

)

The initial ins *rument sen-the ASME Code.

Beam profile curves d

sitivity during the performance of should be determined at dif ferent 1.2.e. should be such that it depths to cover the thicknesses falls at the calibration sensitivity of materials to be examined.

or at some point between the Interpolation may be used to calibration sensitivity and the obtain beam profile correction scanning sensitivity, for assessing flaws at intermediate depths for which beam profile has c.

RF Waveform not been determined.

A record of the RF Beam profile measurements (radiofrequency) pulse waveform from should be made at the sensitivity a reference reflector should be required for sizing.

For example, obtained und recorded in a manner sizing to a 20 percent DAC criteria that w111 permit extraction of requires that the beam profile be frequency amplitude information, determined at 20 percent DAC.

At the highest amplitude portion of the beam, the RF return signal 2.

CALIBRATION should be recorded before it has been rectified or canditioned System calibration should be for display.

This should be performed to establish the OAC determined on the same reflector curve and the sweep range cali-as that used in 1.1.b. above.

bration in accordance with This record should be retained Article 4,Section V of the g

for future reference.

ASME Code or Appendix I to a l Section XI.

Calibration d.

Screen Heigr.t Linearity should be confirmed before and after each RPV examination, Screen height linearity of or each week in which the the ultrasonic instrument should be system is in use, whichever determined according to the manda-is less.

Where possible, tory Appendix I to Article 4 the same calibration block Section 7 of the ASME Code or should be used *(or successive Appendix I to Section XI of the inservice examinations of the ASME Code.

RpV.

e.

Amplitude Control Linearity 2.1 Calibretion for Manual Scanning Amplitude control should Se For manual sizing of flaws, determined according to the man.

static calibration may be used if datory Appendix II of Article 4, sizing is performed using a static Section V of the ASME Code or Appendix transducer.

,When signals are I to Section XI of the ASME Code.

maximized during calibration, they should also be maximized f.

Angle Beam Profile during sizing.

For manual Characterization scanning for the detection of flaws, reference hole detection The vertical beam profile should be shown at scanning should be determined for each search speed and detection level D

unit used during the examination by set accordingly.

a procedure similar to that outlined 1.150-11

2.2 Calibration for Mechanized 2.3 Calibration Confirmation Scanning Calibration confirmation per-When flaw detection is to be formed as mid-shift or interim done by mechanized equipment, the confirmation between on-site calibration should be performed calibrations should comply with using the following guidelines.

stability requirements in T-433, Article 4,Section V of the ASME a.

The DAC curve should be

Code, established using either a moving transducer mounted on the mechanism that will be used for examination When an electronic simulator of the component or a mechanism is used for on-site calibration that duplicates the critical factors confirmation after a Code-required (e.g., transducer mounting, weight, block calibration performed off-pivot points, couplant) present in site, the following should also the scanning mechanism.

apply:

b.

Calibration speed should be

a. Complete system performance a;; or higher than the scanning speed, should be maintained stable prior to except when correction factors off-site calibrations and on-site established in 2.2.d. are used, calibration confirmation by use of target reflectors.

The target c.

The direction of transducer reflectors should be mounted with movement (forward or backward) during identical physical displacement in calibration to establish the OAC both the off-site calibration curve should be the same direction facilities and the on-site mecha-during scanning unless it can be nized equipment.

Each on-site shown that a change in scanning periodic calibration should be direction does not reduce flae preceded by complete system p?r-detection capability.

formance verification using a minimum of two (2) target reflec-d.

One of the followin9 tors separated by a distance repre-alternative guidelines should be senting 75 percent of maximum thick-followed to establish correction ness to be examined, factors if stetic calibration is used.

b. Written records of calibra-tions should be established for (1) Correction factors between dynamic and static response should both target reflector responses and Code calibration block DAC be established using the basic curves for each transducer.

These calibration block or, written records may be used to monitor drift since the original (2)

Correction factors should be recorded calibration, established using models and taking scaling factors into consideration c.

Measures should be taken to (assumed scaling relationship should ensure that the different variables be verified) or, such as temperature, vibration, and shock limits are minimized by (3) Correction factors should be controlling packaging, handling, and established using full scale storage.

mockups, t

L15012

a 2.4 Calibration Blocks 3.1 Internal Surface Calibration blocks should The capability to effectively

/ comply with Appendix 1 to Section detect defects at the internal

~

XI or Article 4,Section V of the clad / base metal interface shall be ASME Code.

When an alternative calibri-considered acceptable if the exami-tion block or a new conventional block is nation procedure (s) or technique (s) used, a ratio between the DAC meet the requirements of Section 6.0 curves obtained from the of this document and demonstrate original block and from the new the following:

block should be noted (for reference) to provide for a meaning-

a. Procedures for examination ful comparison of previous and from the outer surface, or when using current data.

full vee from the inside surface, should include the use of the 2 percent The calibration side-drilled notch which penetrates the internal holes in the basic calibration block (clad) surface of the calibration and the block surf ace should be protected blocks, defined by Section XI, so that their characteristics do not Appendix I, Figure I-3131 or change during storage.

These side-Section V, Article 4, Figure drilled holes or the block surface T-434.1.

Procedures for exam-should not be modified in any way ination from the internal surface (e.g., by polishing) between successive when not using the full vee examinations.

If the block surface or should conform to paragraph the calibration reflector holes have 3.1.b. below.

been polished by any chemical or mechanical means, this fact should

b. An alternate reflector, other

} be recorded.

than the 2 percent notch described above may be used provided: 1) that it 3.

EXAMINATION is located at the clad / base metal interface or at an equivalent distance from the surface, 2) that it does The scope and extent of the not exceed the maximum allowable ultrasonic examinations should defect size, and 3) that equivalent comply with IWA-2000,Section XI of or superior results can be

'the ASME Code.

demonstrated.

If electronic gating is used to

c. The examination procedure (s) define the examination volume within should provide fnr volumetric examin-which indications are recorded, the ation of at least one inch of metal start and stop control points should as measured perpendicular to the include the entire required thickness nominal location of the base metal-including the material near each cladding interface.

surface.

If a single gate is used, it should be capable of recording multiple indications appearing in 3.2 Scanning Weld-Metal Interf ace tha gate.

Alternative means of recording may be used provided The beam angles used to scan they do not reduce flaw detection welds should be based on the and recording capability.

geometry of the weld / parent metal interface.

Where feasible for welds Examination should be done with such as those identified in Section D a minimum 25 percent scan overlap T-441.4.2 of Article 4,Section V of based on the transducer element the ASME Code, at least one angle size.

should be such that the beam is per-1.150-13

pendicular (+ 15 degrees to the 6.2 Indications with Changing Metal perpendicular) to the weld / parent Path metal interface, or it should be i

a.

Indications that change metal I demonstrated that unfavorably oriented planar flaws can be ath distances (Indicating through-detected by the VT technique being wall dimension) when scanned in used.

If this is not feasible, use accordance with the requirements of os alternative volumetric NDE tech-ASME Section XI, for a distance niques, as permitted by the ASM' greater than that recorded from the uode, shau,id be considered, calibration reflector should be recorded.

4.

BEAM PROFILE b.

Reflectors which are at metal (Delete entire paragraph.

paths representing 25 percent and greater This section included in Recommended of the through-wall thickness of the Change 1.2.f., Angle Beam Profile vessel wall measured from the inner Characterization.)

surface should be recorded in accordance with the requirements of ASME Section XI and characterized 5.

SCANNING WELD-METAL INTERFACE at 50 percent DAC.

(Delete entire paragraph.

This C.

Reflectors which are within section included in Reccamended the inner 2E percent of the throughwall Change 3.2, Scanning Weld-Metal thickness should be recorded at Interface.)

20 percent DAC.

Characterization should be in accordance with the demonstrated' methods under paragraph 6.0.

6.

KECORDING AND SIZING Where the indication is sized at 20 percent DAC, Nis size may be I

The capability to detect, corrected b tracting the beam record and size the flaws delineated width in th

  • ir ugh-thickness by Secticn XI, !WB-3500 should be direction ob,o v.d from the calibra-demonstrated.

The measurement tion hole (between 20 percent DAC tolerance established should be points) which is at a depth similar applied when sizing flaws to the flaw depth.

If the indica-detected and recorded during tion exceeds 50 percent DAC, the I

scanning (see paragraph 7.a.).

length should be recorded by measuring the distance between 6.1 Geometric Indications 50 percent DAC levels.

The determined size should be the

{

Indications determined to be larger of the two.

from geometric sources need not be sized.

Recording of these indica-tions should be at 50 percent DAC.

6.3 Indications without Changing When indications are evaluated Metal Path as geometric in origin, the basis I

for that determination should be a.

Indications which do not change described.

After recording metal path distance when scanned in sufficient information to accordance with the requirements of identify the origin of the ASME Section XI and are within the geometric indication, further outer 75 percent of the through-wall recording and evaluation are dimension should be recorded when any not required.

continuous dimension exceeds one inch.

1.150-14

1 b.

If the indication falls within

7. REPORTING OF RESULTS the inner 25 percent of the through-wall x
dimensions, it should be recorded at Records obtained while following d 20 percent DAC and evaluated at 50 the recommendations of regulatory percent DAC.

positions 1.2, 3, and 6, along with discussions and explanations, c.

Precautionary note:

Indica-if any, should be kept available at tions lying parallel to welds may the site.

If the <ize of an indication, appear as nontraveling (without changing as determined ir rt lulatory positions metal path) when scanned by parallel 6.2 or 6.3, ex'n the allowable moving transducers whose beams are aimed limits of Sect 1 f af of the normal to the weld, ie. at 90.

Multiple ASME Code, the indications scans, however, may reveal that these should be reported as abnormal indications are traveling indications, degradation of reactor pressure If so, recording and sizing are to be boundary in accordance with the done in accordance with paragraph 6.2.

recommendation of regulatory position 2.a(3) of Regulatory Guide 1.16.

6.4 Additional Recording Criteria The follow 1 information Along with the report of ultra-should also be rt orded for indica-sonic examination test results, the tions that are reportable according following information should also to this regulatory position:

be included:

a.

Indications should be recorded

a. The best estimate of the at scan intervals no greater than
one-fourth inch, tolerances in sizing the flaws at the sensitivity required in r"

Section 6 and the basis for this b.

The recorded information should estimate.

include the indication travel (metal path distance) and the transducer position for 20 percent, (where This estimate rey be determined in applicable), 50 percent, and 100 per-part by the use of additional reflectors cent DAC and the maximum amplitude of in the basic calibration block, the signal,

b. A description of the technique c.

When multi-channel equipment is used to qualify the effectiveness of used in the examination system such the examination procedure, that all examination displays are including, as a minimum, material, not available for simultaneous section thickness and reflectors, viewing, an electronic gating system should be used which will provide

c. The best estimate of the por-on-line reproducible, recorded tion of the volume required to be information, regarding metal path, examined by the ASME Code that has amplitude ud position of all indi-not been effectively examined such cations exceeding a pr.eset level, as volumes of material near each The preset level should be the mini-surface because of near-field or num recording level required.

To other effecte volumes near inter-cnsure that all recordable indications faces betwee ladding and parent are recorded, a preferred method would metal, volumes shadowed by laminar incorporate multi-gates in each channel material defects, volumes shadowed Dmulti-indicationrecordingcapability.

or a single gate for each channel with by part geometry, volumes inac-cessible to the transducer, volumes i

1.150 15 J

o at tected by electronic gating, and Sketches and/or descriptions volumes near the surface opposite of the tools, fixtures and component the transducer.

geometry which contribute to incomplete coverage should be y

included, d.

Provide sketches of equipment 5 'It should be noted that the licen-(i.e., scanning mechanism and transducer see is required to apply for relief holders) tith reference points and from impractical ASME Code require-necessary dimer sions to allow a reviewer ments according to 50.55a of 10 CFR.

to follow the equipment's indication If the licensee is committed to exa-location scheme.

mine a weld as per the inspection plan in the plant SAR, the licensee e.

When other volumetric tech-is required to file an amendment niques are used, a description of when the commitments cude in the SAR the techniques used should be cannot be met.

included in the report.

l 8

l d a VALUE/ IMPACT STATEMENT

1. PROPOSED ACTION demonstrated without doubt that the flaw will not grow and has not been growing,a ratherlarge fla w can be tolerated.

1.1 Description Crack initiation and growth is also a pctential problem in cases where it is probable that no cracl: exists, but where ne present ir. service examination procedur, for there is a cluster of small rounded inclusions. These clusters ultrasonic examination require improvement in order to of inclusions should be monitored by Ul to ensure absence consistently and reliably characterize flaws in reactor of cracks and crack growth, pressure vessel (RPV) welds and RPV nozzle welds. De apparent low level of the reproducibility of detection, Where the rate of fla growth is expected to be large or location, and characterization of flaws leads to lengthy is uncertain, even a small fisw may be of concern. To discussions and delays in the licensing process. hiuch permit determination of growth rate, the UT procedures attention is paid to the integrity of RPV welds during the should be such that results of successive UT examinations licensing process because the failure probability of a reactor can be compared. With present procedures, these results pressure vessel is considered to be sufficiently low to cannot be compared because of variation in instrument exclude it from conside'ation as a design basis accident.

system characteristics. UT instrument system characteristics ne assumptiot, of a 'ow probability relies heavily on depend on the characteristics of the system's different regularly repeated inservice examination by ultrasonic components. Variation in the characteristics of calibration testing (UT) of welds, blocks can also affect results.

1.3 Need for Proposed Action Guidelines are needed so that uncertainties in flaw charac-terization may be reduced or eliminated, ne safety of the As more reactors start producing powcr, as those in components is evaluated with the help of fracture mechanics.

operation grow older, and as more inservice examinations Flaw sizes need to be known for fracture mechanics evalua-are performed, the number of detected flaws with uncertain tions. Uncertain determination of flaw sizesleads to uncer-characteristics (size, orientation, and location) is likely to tamtiesin the determination of the safety of the components, increase. Flaw characterization is essential for flaw evalua.

Uncertainties in component safety lead to delays in licensing.

D tions required by the ash 1ECodeand by NRC to determine There is a need to specify and standardize the performance the structuralintegrity of nuclear reactor components when required of most UT system components to achieve better aave valid background consistency in UT results so that delays in the licensing such flaws exist. It is essential data for the flaw evaluations required by Section XI of the process may be reduced.

AShtE Code. Based on the information gathered according to AShiE Code requirements,it is often difficult to aess This guide will provide supplementary procedures with wtether or not the flaw has grown between examinations.

the objective of improving conventional UT procedures, as ne procedures now in use do not require the recording of defined in the ash!E Code. His guide is based partly on the certain information th6t can be important in later analysis information available in literature concerning both U.S. and for determming the location, dimensions, orientation, and European procedures and partly on the judgment of the growth rate of flaws.

NRC staff and their consultants. On the basis of support work being performed at the Oak Ridge National bboratory.

The lack of standardization in the use of UT equipment the staff plans to issue a revision to this guide that should and procedures leads to uncertainty concerning the results further improve flaw characterization, obtained For example, transducer characteristics such as beam spre ad, damping characteristics, and frequency The use of new technNues such as holography or synthetic for peak response are not defined, and there is no provision aperture imaging of flaws by UT that have not been imple-to keep trr.ck of these from one examination to the other.

mented into practice ana could considerably increase the Similarly, characteristics of other UT system components cost of inservice examination is not being proposed here.

such as the pulser, receiver, amplifier, and Mdeo display screen may vary from one examination to another, and all 1.3 Value/ impact of Proposed Action these characteristics can influence the magnitude of the flac indications. Derefore, well-defined criteria for supple-1.3.1 NRC mentary UT procedures are needed so that it will be possible to correctly characterize flaws, estimate flaw growth, and Reporting UT exarQtion results as indicated in this guide have reproducible results from inspections performed at would help the NL eff and their consultants to better different times using different equipment.

assess the resultr

  • data. At present, the NRC ttaff must spend a grt t ' G of time on controversy over deter.

B more important than the flaw size. For example,if a flawis In many instances, the rate of flaw growth can be even mining the safetc sf components from inconsistent UT results. bck of faith in flaw size determination from found in an RPV nozzle or belt-line region and it can be uncertain UT results points toward the adoption of some 1.150-17

}

. n conservative safety measures that are undesirable, for the

i. Providing more consistent UT procchres for flaw most part, to the industry managers. Licensing delays occur characterization, thereby leading to procedures that because decisions have to be made on the basis of uncertain ensure lower probability of missing large flaws and l

irdoimation. Flaw size determination from consisunt UT ensuring greater safety ior the nublic, industrial results would help remove or reduce the uncertainties and workers, and government employees.

debates over the safety issues. Because of the above, NRC staff time for review of reported data and interpretation of indications is likely to be reduced.

1.3.3.2 Impact. There will be major impact in the foUowing three areas:

1.3.2 Other Gorcinment Agencies

a. Qualiti control oi the UT equipment Not applicable, unless the government agency is an At present,requirementsin the ASSIE code forquality applicant, such as TVA.

control of UT equipment are marginal; for example, there are no direct requirements to control the quality of UT transducers Criterion XII,' Control or Measuring 1.3.3 Industry and Test Equipment," of Appendis D,"Quality Assur-anee Crite-ia for Nuclear Power Plants and Fuel Repro-The value/ impact on industry of the regulatory guide cessing Plants,"to 10 CFR Part 50 requires,in part,that positions is stated by each position in the appendix to this measures be established to ensure that instruments used value/ impact statement. Some highlights of the value and in activities affectiny quality are properly controued, impact of the regulatory guide positions are stated below.

calibrated, and adjusted at specified periods to maintain accuracy within necessarylimits.The recommendations of this guide will help to bringabout unifor ~ ilty in the 1.3.3.1 l'alue. This regulatory guide specifies supplemen-quality control procedures among different companies tary procedures that wiu lead to the following advantages:

and will ensure that quality control measures are taken to ensure reliability and reproducibility of UT results.

a. Attaining greater accuracy and consistency in flaw No new UT equipment will be needed to follow the characterization, recommendations of this guide. Ilowever, the quality control measures recommended for UT equipment
b. Providing information for consistent flaw characteriza-will impose extra cost burdens that are difficult to q tion at NRC review time and thus reducing NRC staff cstimate without feedback from industry, cffort in review of flaw indications.
b. Increase in examination time
c. Ilyng assess flaw growth.

This guide would recommend, for the first time, that

d. Providing a more reliable basis for flaw detection and indications with significant length ofindication travel evaluation, which should help in the uniform enforce-(lcrger than the standard calibration holes) or with ment of rules and the avoidance of delay in licensing significant depth dimensions be recorded. It is not decisions.

expected that the slag type of flaws, which ere common among welds, or geometric reflectors will give signif-

e. Reducing licensing time for reviewing examination icant traveling indications within the guidelines pro-results, which will aid in the reduction of reactor down-posed. IIence, no substantial increase in recorded time during examinations and will be of great benefit indications as a result of this recommendation is to industry. With present construction costs of about expected; however, the exact increase is difficult ta 1.3 balic,n dollars fora 1000-megawatt reactor anu the predict or estimate.

average size of a reactor running around 1100-megswatt capacity, the savings per day by eliminating reactor Reporting of indications associated with flaws larger downtime are likely to be $500,000 or more.

than 1 inch (indications larger than 1 inch plus beam spread at 20 percent DAC level)is also new. RPV welds

f. Avoiding unnecessary repairs due to flaw size uncer-are examined by radiography, and no flawslar;er than tainties.

three-quarters of an inch are acceptablein these welts.

Because of this acceptance length, only new service-

g. Reducing radiation exposure to personnel by helping induced flaws larger than 1 inch,of which there should to eliminate unnecessary repairs. The radiation not be many, are expected to be identified and reported esposure during repairs is usually many times the as a result of this recommendation.

exposure during eramination, so a r.-t reduction in radiation exposure is expected.

Because of the above two new reporting recommenda-tions, there may be an increase in examination time

h. Red seing margins of error in estimates of flaw growth and dollar cost that is difficult to estimate. This wiu and thus helping reduce overconservatise estimates depend on how many significant flaws are detected and decisions on flaw acceptance, and how large and complex they are.

1.150-18

c. Radiation exposure 2.3 Comparison of Technical Alternatises Recommendations of this guide apply to the examina-Imposing inservice examination of RPV welds by the use tion of RPV welds and RPV nonle welds. RPV welds of holography, synthetic aperture imaging technique, or are usually examined by automated equipment, and acoustic emission, all of which are stillin the stage of proto-data are collected on tape. Threfore, no increase in type development and have not been proved effective for radiation exposure is anticipated as a result of the field use, would not be justifiable on the basis of either regulatory guide positions addressing RPV weld cost or effectiveness.

e aminations.

RPV nozzle welds are sometimes cumined by 2.4 Comparison of Procedural Alternatives automated equipment but in most cases by manual UT. An increase in radiation exposure to eumination Leaving the situation as it is would mean that continued personnel may be expected whde RPV nozdes are attention and manpower would have to be devoted by the being m anually examined. The probable percent NRC staff to investigate the uncertainties associated with increase in exammtion time or raJiation exposure is flaw growth on a case-by-case basis. The low levei of impossible to estimate without field data and research confidence in the present techniques means that excessive effort. Requirements for reporting traveling indica-margins would continue to be used in the flaw acceptance tions and indications associated with flaws larger than criteria. Also, unnecessary cutting and repair attempts to 1 inch may lead to an increase in oecupational remove suspected flaws may result.

exposure in those cases in which the above indications are found and additional examination is required. The The procedures recommended in this guide have been magnitude of this additional ;xposure can only be shown to oe effective in practice, although they are not in assessed on a case-by case basis. It should be noted general use in the United States. Including ti.ese procedures that radiation lesels at vessel noule regions are as regulatory guide recommenda!!ons should esult in their reported to range from 0.5 to 2.0 rem / hour. Total wider use and consequently their improvemen t. After these person-rem doses can be drastically reduced by procedures have been accepted by the indu>try, we will shielding and local decontamination, seek their inclusion in the ASME Code. Some of these procedures have already been sent to the ASME fcr considera-ne guide is not expected tc have any adverse impact on tion and inclusion in the present ASME Code procedures other government agencies or the public.

for ultrasonic examinations.

1.3.4 1%lic 2.5 Decision on Technical and Procedural Alternatives No impact, the public can be foreseen. The onN identifiable value is a slight accelerati m in the review On the basis of the above, it appears desirable to issue a

process, regulatory guide to provide recommendations for improving ASME Code procedures. These recommendations, which 1.4 Decision on Proposed Action are based on the advanced state-of the-art UT procedures in current use by some organizations, would improve the The Office of Nuclear Reactor Regulation (NRR) has ability to detect and characterize flaws without imposir.g stated the neeJ for this guiJe to help them and their new, unproved techniques for flaw detection on industry, consultants in evaluating the size and significance of the flaws detected during inservice enmination to ensure the
3. STATUTORY CONSIDERATIONS integrity of reactor pressure vesstis between periods of eumination. It would therefore be advisable to issue this 3.1 NRC Authority guide.

The authority for this guide is derived from the safety

2. APPROACll requirements of the Atomic Energy Act of 1954, as amended, and the Energy Reorganization Act of 1974,asimplemented 2.1 Technical Alternatives by the Commission's regulatwns. In particular, 50.5 5a, "Codes and Standards," of 10 CFR Part 50 requires, in Altcrnatives wmld include requirin g the use of holography, part, that structures, systems, and components be designed, synthetic aperture im aging, acoustic emission, neutron fabricated, erected, constructed, tested, and inspected to radiography, or a combination of the above during RPV quality standards commensurate with the importance of inservice examination.

the safety function to be performed.

2,2 Procedural Alternathes 3.2 Need for NEPA Asse sment One alternatise is to lease the situation as it is. A second The proposed action is not a major action, as defined by alternative is to request change of the ASME Code require-paragraph 51.5(a)(10) of 10 CFR and does not require an ments.

environmentalimpact stattment.

1.150-19

)

4. RELATIONSlilP TO OTilER EXISTING OR PRO.

difficult for the NRC staff or their consultants to review, POSED REGULATIONS OR POLICIES analyze, and assess the UT data to determine the flaw size and evaluate the system safety when the data are made Recommendations of this guide would be supplemental available to NRC at a 1 ster date. De present data obtained to the requirements of Section XI, "Rules for Inservice from UTequipment of uncertain and unspecified performance Inspection.of Nuclear Power Plant Components," of the lead to discussions and delays in the review process resulting ASSIE Code, which is adopted by 50.55a, "Codes and in loss of NRC staff time and loss of plant availability Standards," of 10 CFR Part 50.

and power generation capacity for the utilities. Rese situations definitely need to be avoided as much as possible.

5. SUhthl ARY This guide is aimed at achieving this purpose by issuing recommendations that will be supplementary to the existing This guide was initiated as a result of a request from ash!E Code UT procedures. The issue remains whether to NRR. Preliminary results of the round robin UT examination wait for the development of advanced NDE techniques and procedures following ash {E Code procedures indicate a continue with the present AShtE Code procedures resulting need for additional guidelines to the exiqing AShlE Code in uncertainties, delays, and discussions or to encourage procedures to control equipment performance, calibration improvement in the present state of the art of conventional block specifications, and scanning procedures to improve the UT. The decision appears to be obvious that we should use reproducibility of results and detectability of through thick-conventional UT based on engineering judgment until some ness flaws.

new techniques for flaw detection and sizing can be proved effective in the field. This guide is aimed at providing the hiinimum ash!E Code requirements do not specify the recommendations needed to improve on the ash!E Code details of recording requirements that are essential to UT requirements until proven advanced NDE techniques evaluate flaws. This deficiency in the Code rules makes it are available.

G 8

1.150-20

APPENDIX TO VALUE/ IMPACT STATEMENT O

)

Values that will result from this regulatory guide are now apply to the examination of the RPV, requite calibra-

'V much easier to perceive than the impact. It is very difficult tion against the calibration block only "prior to use of the to assess the real impact because the kind of statistical data system." It is considered that the present 1977 ASME Code needed is simply not avadable at this time.One wayin which rules are not adequate to control potential problems in the we hope to estimate the impact is through industry feed-vanation of instrument performance characteristics. There-back af ter the guide has been issued.

fore, the recommended calibration before and after each examination is a more reliable approach to instrument We hate made an attempt, in a qualitative manner, to performance checks. The abose position is not more con-estimate the valuehmpact of regulatory guide positions, servative than the previously accepted 1974 Code rules, but is position by position, as follows:

more conservatise if 1977 rules are considered.

1. INSTRUM ENT PERFORM ANCE CllECKS Considering the requirements of Article 4,Section V (1977), the above position will mean a calibration check Recording the characteristics of the ultrasonic testing each week the system is in use or before and after each (UT) examination system will be usefulin later analysis for RPV examination, whicheser is less, instead of before each determining the location, dimensions, onentation, and examination. A calibration check against the calibration growth rate of flaws. System performance checks to deter-block takes 15 to 30 minutes for manual UT and for mine the characteristics of the UT system will be made automated UT equipment where provision is made to shortly before the UT examinations. Each UT examination calibrate the equipment without having to remove the trans-wdl therefore be correlated with a carticular system per-ducers from the roteting scanning arm of the mechanized formance check. This practice will help to compare results.

scanner. In some cases, transducers have to be removed Dese determinations will help make it possible to judge from the scanning arm for calibration of the UTinstrument; whether differences in oberotions made at different times in these cases, a calibration check may take from 30 to 60 are due to changes in instrument characteristics or are due minutes. The added cost of the above would be in terms of to real changes in the flaw size and characteristics.

additional time spent by the examiner and would occur e4h week or once for each RPV examination, depending It is recommended that, as a minimum, instrument on whether or not 'he examination k completed in less D checks should be verified before and after examining all the th.an a week. No additional radiation exposure is expected welds that need to be examined in a reactor pressure vessel because of this position.

dunng one outage.

3. NEAR SURFACE EXAMINATION AND SURFACE Performance of these instrument checks is likely to add RESOLUTION a few thousand dollars to test equipment cost and to take i to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of examination time before and after each reactor This position recommends that an estimation of the pressure vessel (RPV) examination. The examination equip-capability to effectively detect defects at the metal front ment is usually idle between examinations. Performance and back surfaces of the actual component should be made checks on the examination equipment could be performed and reported. This will not requite any additionalcalibration during these idle periods. These performance cheeks are not or examination time but will simply require an estimate of hkely to reduce the number of examinations that a carticular this capability by the examiner, which will be reported to UT system could perform in a year. No additional radiation NRC. No additional radiation exposure is expected because exposure is expected because of this position.

of this position.

2. CAllBRATION
4. BEAM PROFILE 1

According to this position, system calibration should be This position recommends tnat the beam profile (for j

checked to venfy the distance-amplitude correction (DAC) each search unit used) should be determined if any signif-curve, as a minimum, before and after each RPV examina-icant flaws are detected during the RPV examinatios tion (or each week the system is in use, w hichever is less) or each time any component (e.g., transducer, cable. connector, Assuming that no rnore than three search units are likely pulser, or receiver) in the examination system is changed.

to be used during an RPV examination, this step is likely to require no more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of examination time. No Subarticle 1-1230, Appendix 1,Section XI. ASME BAPV additional radiation e xposure is expected because of l

Code (1974 edition), which applied to the inspection of the this position.

l RPV, required ca'ibration using the basic calibration block I

at "the start and finish of each examination, with any change

5. SCANNING WELD. METAL INTERFACE D in examination personnel and at.least every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during an examination." lloweser, the 1977 rules of Article 4 This position recommends that the beam angles used to (T-433),Section V, which are referenced by Section XI and scan welds should be based on weld / parent metal interface 1.150-21 J

e geometry and at least one of these angles should be such that on the screen larger than the indication on the screen from the beam is almost rerpendicular(tl5 degrees to the perpen-the calibration holes (1/2-inch hole for a 12-inch weld dicular) to the weld / parent-metal interface, unless it can be thickness. 3/8-inch hole for an 8-inch thickness), this demonstrated that large (Code-unacceptable) planar flaws recommendation will not result in any more recording of unfavorably oriented can be detected by the UT technique.

indications. If the RPV welds being examined have several indications with travel in excess of the calibration hole On the buis ofinformation available,it appears that it is diameter, the examination and recording time will be difficult,2,3 to de tec t large planar flaws (e.g., service-induced increased for the investigation of these flaws, depending s

fatigue or stress corrosion cracks) oriented at right angles to on the number of these indications. Slag inclusions in welds the surface, using the ASME Code UT procedure. Ilowever, are generally long cylinfrical defects and do not have much the option is being prosided to demonstrr.te that such flaws depth unless they are associated with shrinkage or service-can be located by conventional methods or by using new induced cracks. These slag inclusions are not expected to advances in UT techniques. In these cases, the technique will increase the number of indications that will be recorded.

be acceptable as a volumetne examination method. Otherwise, Increase in examination time will depend on the number, the use of high-intensity radiography or tandem probe UT size, and complexity of geometry of through-thickness technique, among other techniques, should be considered, indications.

The above type of flaw is the most significant but the For RPV girth or nozzle welds where examination is most difficult to detect. Because of this, the present recom-performed by automated equipment and data are recorded mendations are being made despite their potential impact on tape, this position will mean no increase in examination on cost and radiation exposure.

time or radiation exposure; but interpretation, analysis, and repor;ing time for these depth indications wiu increase. The lhe potentialimpact may be as follows:

extra burden in terms of dollar cost will depend on the number, size, and complexity of flaws, and there are no

a. Additional NRC staff time may be needed to evaluate rational bases or data available at this time to estimate the the effectiveness of UT techniques on a generic basis to increase in the cost of examination.

detect perpendicular planar flaws. After techniques are recognized to accomplish the above, NRC staff time that is For RPV welds, mostly nozzle welds, where examination being spent current', on evaluating problems on a plant by-is performed manually and data are not recorded on tape, plant basis is expected to be considerably reduced.

this position will mean extra examination time and increased radiation exposure to the examiners, increase in dollar cost

b. Reactor downtime may increase, depending on the and radiation exposure will again depend on the number, examination time differentials between the conventional size, and complexity of indications, and there are no bases and refined techniques. This may, however, be offset by a or data available to estimate this increase, reduction in the downtime currently needed for NRC experts to evaluate data that sometimes requires further 6.2 Nontraveling Indications clarification and reexamination.2 A This position also recommends the recording of nontravel-
c. Additional cost might be incurred in changes needed ing indications above 20 percent DAC level that persist for to add transducers or data-gathering capability to existing a distance of more than I inch plus the beam spread, automated equipment or to automate current manual According to NB 5320, Radiographie Acceptance Standards, examinations. Automation of current manual techniques is Section Ill, Division 1, ASME Code,1977 edition, flaws hk'ly to reduce radiation exposure to personnel.

larger than 3/4 inch for weld thicknesses above 21/4 inches are not acceptable. Because of this requirement, it is

6. SIZING AND RECORDING OF INDICATIONS expected that no flaws larger than 3/4 inch in lergth are present in the RPV welds, and if indications are detected 6.1 Traveling Indications that suggest flaws larger than 3/4 inch, there is a strong possibility that these may be service-induced flaws. Service-This position recommends the recording of traveling induced flaws are rare in RPV welds, and it is therefore indications. If RpV welds do not hase any travelindications not expected that additional indications would hase to be record:d because of this position. Ilowever, if such indica-

_I"Probability or Detec ting 11anar Defects in lleavy Walt Wetas by tions (over 1 inch) are detected, examination time for Ng*e'ndte[er a$ity$e#ItNeNIf1t.."N. N r's,"b N"o$

automated recording and examination time plus radi tion p

Nurnberg i15.

exposure for manual UT examinations will be increned.

There are no rational ba?cs or data available to estimate the 2"Interim Technical Report on BWR f eedwater and Control floJ Drtwe Heturn Line Norrie tracking," NURI G-o312, J uly 1977, p. 3.

impact of regulatory position 6.,.

bAnalpis of the Ultrasonie IAaminations of FVRC Weld Speci.

7. REPORTING OF RESULTS mens Iss, 202, and 203," R.A. Duchanan, Pressure Vessel Research Committee ("V RC) Report, August 1976.

j This position recommends that the areas required to be l

l 4"Summary of the *.)etection and i valuation of Ultrasonic Indica-examined by the ASME Code that have not been effectively I

tions 1dwin flatch Urut t Reactor Pressure Vessel,' January 1972, i

Georgia Power Company, examined and an estimate of error band in sizing the flaws l

l l

1.150 22

snould be brought to the attention of the NRC when the of this guide, those insenice and presenice examinations results are reported. This effort rnay take about $ hours in performed in the past. Such a policy would tend to be

, reportwriting time, overly conservative and would put a heavy burden on all

,1 plant owners. Although UT examinations have missed some

8. IMPLEMENT ATION flaws in the past, there appears to be no immediate danger from the estimated flaw distribution probability to warrant it should be noted that the recommendationsof this guide such a strong action. Therefore, this alternative was not are not intended to apply to those preservice examination adopted.

tests already completed. Ilowever, the licensees may consider repeating their presenice examination tests or 8.2.0 Secodd Alternatirc using the recommendations of this guide any time at their option to avoid possible flaw interpretation problems at a in the past, several instances have t.een noted where the later date. Flaw interpretation problems may occur if minimal Code UT examination procedures have not been traveling indications identified as significant according to adequate for detecting and sizing flaws. Discussions and the recommendations of this guide do not correlate with undesirable licensing delays were frequently the result. As presenice volumetric NDE results and hence would be more plants begin producing power and existing plants grow assumed to have been senice induced. It would be difficult older, more flaws may be expected in the weld areas. These to show that these indications arose from fabrication flaivs.

flaws may be generated as a result of fatigue, stress corrosion, Therefore, licensees would be well adsised to consider the or other unanticipated factors. It is imperative that the above possibihdes.

guide recommendations for supplementary UT examination procedures be used in the future to maintain an acceptable 8.1 Alternatives level of safety at these welds. The second alterri.ive was therefore selected for applying this guide to the presenice The following alternatives were considered in applying and inservice examination of RPV welds.

the recommendations of this guide, it is expected that inservice UT examinations will detect

1. To aprily the recommendations of the guide to all the flaws generated during plant operation, whereas presenice presenice and insenice examinations that have examinations will provide UT examination data for sub-already been performed, sequent comparisons. First, a radiographic examination is performed of all the vessel welds under Section 111 of the B
2. To apply the recommendations of the guide to all ASME Code. After this examination, a UT presenice exam-future preservice and inservice examinations per-ination of welds is performed to serve as a supplementary formed af ter the issuance of the guide, volumetric examination. Because of the above, these pre-senice examinations are not as important as insenice exam-8.2 Discussion of Alternatives inations. It was therefore decided that the guide recommenda-ticos should apply to judging the inse nice examination results 3.2,1 First Alternative for those examinations performed immediately after the issuance of the guide; however, the guide recommendations Alternative I would infer that all RPV welds examined should apply to rresenice examinations beginning 6 months as per the current code requirements are at a quality level after the issuance date. The NRC staff considered this that would not ensure an acceptable safety performance.

approach best because of the difficulties being experienced TE approach would also mean that all the plants would in reviewing insenice UT examination data from the have to repeat, in accordance with the recommendations different plants.