Text
ESlyQh h/ IMdb GPU Nuclear Corporation G U Nuclear.
aTa*
a Middletown, Pennsyl<ania 17C57 0191 717 944 7621 TELEX 84 2386 wees okst Dial New January 15, 1988 C311 2004 4410-88-L-0003 Mr. William T. Russell Region I, Regional Administrator U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406
Dear Mr. Russell:
4Three Mile Island Nuclear Station, Units 1 and 2 (THI-l and TMI-2)
Operating License Nos. DPR-50 and DPR-73 Docket Nos. 50-289 and 50-320 GPUN Response to IE Bulletin 87-02 IE Bulletin 87-02 requested that licensees 1) review their receipt inspection requirements and internal controls for fastenert, and 2) independently determine, through testing, whether fasteners (studs, bolts, cap screws and nuts) in stores at their facilities meet required mechanical and chemical j
specification requf rements.
4 f<esponse to Item No.1:
la. Describe the characteristics currently examined during receipt inspection of fasteners (i.e., head markings for grade and manufacturer symbols, review of certified material test report or certificate of conformance.)
Response
Receipt inspection of safety-related fasteners at TMI is controlled under GPUN Procedure 6110-QAP-7210.02, "Quality Assurance Modification /
Operations Section Inspection Program." Characteristics normally examined during the receipt inspection of these fasteners include:
1)
Identification and Marking (includes verification of head markings for grade),
- 2) Physical Damage.
-o
@o
- 3) Physical Propertf as (verification that the requirements specified on co o chemical and physical test reports cortply with industry standards, if ou aplicable),
da oo
- 4) Dimensions (limited to overall dimensions as required by the
{
procurement dricument),
h
- 5) Workmanship, and i
GPU Nuclear Corporation le a subsidlary of the General Public Utilitles Corporatlon f
~
l
\\
C311 200a January 15, 1988 4410-88-L-0003
- 6) Review of Documentation [ Certified Mill Test Reports (CMTR) and/or Certificates of Conformance (C0C) are reviewed and verified that only properly authorized vendor QA personnel have signed, if required by 1
the procuremnt documents].
l Non-safety related fasteners, those not ccntrc11ed under the GPUN Operaticnal Quality Assurance Plan, do not normally receive quality control inspection unless specified in the procurcment documents.
l 1b.
Describe the internal controls utilized during storage and issuance from stock to assure the appropriate use of faster.ers.
i
Response
The primary internal control relative to the storage and issuance of safety-related fasteners froin stock to assure the appropriate use is the i
Quality Assurance Tag. The tag as described in GPUN Procedure 6110-QAP-7210.02 is issued by quality control receipt inspectors and provides for the identification of code, seismic, system, and component end use, i
Non-safety related fasteners are issued through the appropriate warehousing methods with no QC involvement.
iponse to Item Nos. 2 through 6:
GPUN's sample of fasteners consisted of 13 safety related bolts and studs,12 safety related nuts,10 non-safety related bolts and studs, and 9 non-safety related nuts.
Item No. 3 of IE Bulletin 87-02 requested that we include a sample of typical nuts that would be used with each fastener (one-for-one) selected in response to Item No. 2.
This was not always possible on a one-for-one basis because nuts were not ordered for bolts in every instance.
Where bolts were ordered with nuts, the bolt and the associated nut were l
sampled together.
Otherwise, if this were not possible, nuts were sanpled on a representative basis as typical of those that would be used with the fasteners selected.
These fasteners were selected from stock and subjected to the testing prescribed by IE Bulletin 87-02. The safety related fasteners were conprised mainly of ASTM A193 87 bolts / studs with some A325 and A307.
The safety related nuts that were selected were predominantly ASTM A194 grade 2H. One of the safety related nuts was an ASTM AES3 Grade A.
The non-safety related fasteners that were selected were predominantly SAE Grade 5, A325 Type 1, A193 Grades 37 and B8.
The non-safety related nuts selected were all A194 2H.
C311 2004 January 15, 1988 4410-88-L-0003 The samples selected were all representative of fasteners. sed at TMI.
A193 Grade B7 studs with A194 Grade 2H nuts are used extensively in piping / flange bolting.
A325/A307 types are used extensively in structural applications.
All samples were drawn from current stock. THI-1 NRC resident inspector D. Johnson was present when the initial samles were drawn.
Subsequent to the initial draw, additional samples of the non-safety related fasteners needed to be taken.
It was determined that in our haste to respond to this bulletin we had taken some of our non-safety related samples from stock where we could not identify the material specification and grade; and therefore the test results obtained for these samples were inconclusive.
When the additional samples of non-safety related fasteners were taken, the NRC resident inspector was notified.
All testing was conducted by Laboratory Testing, Inc. of Dublin, Pa., a facility approved in accordance with GPUN's Quality Assurance Plan.
Results/ Conclusions Among the samples tested, only two samples exhibited characteristics outside of values prescribed by ASTM Standards:
Sample # THI-31, a 7/8" - 9 X 31/2 A325 type 1 bolt had actual tensile strength of approximately 6% less than that required by the ASTM Standard.
Sample f TMI-80, a 1/2" X 5" hex head SAE Grade 5 cap screw had actual tensile and yield strengths of approximately 6% less than that required by the SAE Standard.
Engineering has evaluated the above two results and has concluded the following:
1.
For sample i TMI-31, this type of bolt (ASTM A325) is used in structural applications for which the AISC (American Institute of Steel Construction) Standard would be used.
The typical AISC allowable tensile limits for design purposes are 40-44 ksi in tension.
Thus, sample
- THI-31, although it exhibits tensile strength slightly less than that prescribed by the ASTM Standard, far exceeds the design limits of AISC which are normally utilized for structural applications. An additional sample, THI-32, was drawn from the same purchase order of stock and tested for confirmation. The results for THI-32 were similar to that of sample iTHI-31.
Although not included with this response, the results for sample THI-32 are available at the site for NRC inspection purposes.
2.
Sample fTHI-80, a 1/2" X 5" hex head SAE Grade 5 cap screw was intended for a non-safety related/not-important to safety application. Therefore, such a slight reduction in tensile and yield strength values is non-consequential.
Plant torquing procedures would typically only allow torque equivalent to N30 ksi which is far below any failure limit.
l l
C311 2004 January 15, 1988 4410-88-L-0003 The results of those non-safety related samles, where substantiating information regarding material specification and grade were not available from procurement documents, were not considered in this evaluation. GPUN issue and installation control procedures would not allow use of these fasteners in safety related applications.
As required by IE Bulletin 87-02, Attachment 1 provides the completed Fastener Testing Data Sheets and Attachment 2 provides the cogleted Data Sumary Sheets. Appendix A gives our addresses for the vendors named in Attachment 1
Also, a brief description of the quality classification system is included as Appendix 0.
Based upon our review of the current procedures, and the sample test results shown in attachments 1 and 2, we believe that the controls in place at TMI are adequate to assure that fasteners used in the plant meet the requisite specifications and requirements and that the operability of safety-related plant components are not affected.
This completes GPUN's response to IE Bulletin 87-02, and no further action as a result of this bulletin is planned.
As discussed with the NRC resident inspector, D. Johnson on January 11, 1988, this letter is being submitted late resulting from the need for confirmation of some of the results from the laboratory.
Sincerely, t
. D. Huk 11 Vice President & Director,THI-1 HDH/HRK/spb:1084 A cc: G. Edison Sworn and subscrib to J. Stolz before me this /
day of R. Conte Ow;ouz
, 1988.
W. Travers
/
[
Document Control Desk 01M f Attachments
/
hotary PuMic 54Aus P. soon, asian rusac Blo0Litswq MM. MWP9ft C004TY M Cousmslos Exyg3 jag gg gggg seates W hseeMbe of estates
APPENDIX B Explanation of the (Quality / Safety) Classification System (Extracted from Section 2.2 of TMI Quality Assurance Plan - 1000-PLN-7200.01) 2.2 Scope The scope of the GPUN Operational Quality Assurance Program includes, but is not limited to, all items and activities applicable to the operation This of TMI-l and Oyster Creek considered to be "important to safety."
term is broader than "safety-related" and encompasses structures, systems and components (including nuclear fuel and radwaste) which have been designated as Safety-Related, Safety Class, IEEE Class IE,
- Ecuipment The Environmental Qualification, Seismic Category I or Fire Protection.
scooe of the Program includes items covered by the Ooerating License and Technical Specifications (excludt non radiological monitoring) and items required by the following:
Title 10, Code of Federal Regulations, Part 50, Appendix A a.
"General Design Criteria for Nuclear Power Plants",
Title 10, Code of Federal Regulations, Part 50, Appendix B b.
"Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants",
Title 10, Code of Federal Regulations, Part 71, Subpart H c.
"Quality Assurance for Shipping Packaqes for Radioactive Material".
d.
Title 10, Code of Federal Regulations, Part 50, Apoendix R "Fire Protection Program for Nuclear Power Facilities Operating orier to January 1, 1980".
United States Nuclear Regulatory Comission Regulatory e.
Guide 1.143 "Design Guidance for Radioactive Waste Management Systems, Structures and Comoonents Installed in Lignt Water Cooled Nuclear Pcwer Plants".
f.
U. S. Nuclear Regulatory Comission Regulatory Guide 1.29 "Seismic Design Classification" and the seismic 6spects of components which nave impact on items important to safety.
Title 10 Code of Federal Regulations, Part 50.49, g.
"Environmental Qualification of Electrical Ecuiement Important to Safety for Nuclear Power Plants".
h.
Other items when designated oy Technical Functions.
Accendix A provides a comparison of the sections of this Plan with the requirements of 10CFR50, Apoendix B; 10CFR71, Subpart 4; ANSI N18.7; and ANSI N45.2.
The GPUN Operational Quality Assurance Program applies to al1 items on the Quality Classification List (QCL).
The QCL will be periodically updated to include new plant modifications or construction or any changes 1,n classification.
The contents of the list will be controlled.
For new design efforts such as plant modifications and new construction, the classification determination is recorded on design criteria documents. New items will be included in the QCL. Documents which control the installation of Important to Safety modifications will be clearly identified as such.
2.201 Activities which are Important to Safety shall include, but not be limited to:
a.
Those activities covered by ANSI N18.7 and Appendix A of Regulatory Guide 1.33.
b.
The requirements of other Regulatory Guides applicable to operations, maintenance, modification, repair and refueling of a nuclear power plant as identified in Appendix C herein, c.
Those activities related to protection against radiation as covered by Title 10, Code of Federal Regulations, Part 20.
i d.
Those activities related to Fire Protection as covered by Title 10, Code of Federal Regulations, Part 50, Appendix R.
e.
Those activities related to Plant Security as covered by Title 10, Code of Federal Regulations, Part 73.55 "Reauirements for Physical Protection of Licensed Activities in Nuclear Power Plants Against Industrial Sabotage."
f.
Those activities defined by procedures which have been designated during the review cycle as "important to safety."
[
l
.r' Sh 1 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-l fastner
Description:
1/2" - 13 X 2 1/4" STUD Description of Sample Stock Location:
IB12L121 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
87
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor:
Texas Bolt Co. (through Nova Machine Products Corp.)
QA Requirements Imposed on Vendor:
PO# 027775; CMTR; COC; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
Signature A
Date
[
8 The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
-wn-3
-,m, m---w,
,%----..,-.-c-ee-
,>-,,-w.
e e.,
ev.+
- - --~
-w+----ee-,--~e-
--_-_m, Sh 2 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-5 Fastner
Description:
1/2" - 13 X 2 1/2" STUD Description of Sample Stock 1. oration:
IB08N014 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
B7
- Class / Procurement Level:
ITS/NSR General Pir.nt Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: A!11ed Nut & Bolt Co.
QA Requirements Imposed on Vendor:
PO# 045939 (Physical and Chemicals reprinted on Allied letterhead);
10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
Date I 4 88 Signature The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) 4
i' Sh 3 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-7 Fastner
Description:
1/2" X 2 3/4" STUD (UNC-2A) Part# L-7793 Description of Sample Stock location:
IEllC045 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
B7
- Class / Procurement level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
STUDS FOR GATE, GLOBE, AND CHECK VALVES Vendor: Crane Co., Chattanooga Div.
QA Requirements Imposed on Vendor:
PO# 257058; Certificate of Conformance; 10 CFR 21 Licensee Representative:
Signature l'
Date
//
88 g -
The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) l
Sh 4 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-11 Fastner
Description:
5/8" - 11 X 4" Fully Threaded Studs Description of Sample Stock Location:
1808N071 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
JB7
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: Allied Nut & Bolt Co.
QA Requirements Imposed on Vendor:
PO# 053947; CMTR; COC/ Chemical and Physicals reprinted on Allied letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representa ve:
h,'
f f
lf/k
//
Date Signature The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) m.
-9
-...y
-c
...-_w
-~
-,m e - -.
Sh 5 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
TMI-15 Fastner
Description:
1/2" - 13 X 4" LONG STUD Description of Sample Stock Location:
1808N052 Material Specification as Documented by Licensee Records:
A193GRB8M Head Marking (Specification and Manufacturer):
B8 HT
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 014255; CMTR documented on Texas Bolt Co. letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
h' I/dd8 Signature Date The sample ID# shell have a prefix that contains the licensee facility initials.
If appilcable, please providh an explanation for your classification system.
(See Appendlx B) y-,
-,--.e y
4
,~,-.
Sh 6 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-19 Fastner
Description:
7/8" - 3 Heavy Hex Head Bolt Description of Sample Stock Location:
lA07J102 Material Specification as Documented by Licensee Records:
A325 Head Marking (Specification and Manufacturer): \\/
4 TlB l
- Class / Procurement Level:
ITS General Plant Application (e.g., Pressure Boundary, Structural)
STRUCTURAL Vendor:
Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 014255; CMTR; 10 CFR 21 Applied by Vendor Licensee Representative:
Date
/ [4-O h Signatur(-
The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
Sh 7 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-21 Fastner
Description:
5/8" - 11 X 4 1/2" Threaded Stud Description of Sample Stock Location:
IB10 Nil 3 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
B7T
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 014255; Chemical and Physicals Reprinted on Texas Bolt Co.
letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
/
M. 88 Date Signature l
fs i
The sample ID# shall have a prefix,that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
-,n-w
-- ---.-. - - - - -,,~.
Sh 8 of 13 1
ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS
~
Fastener Testing Data Sheet
- Sample 10#
THI-25 fastner
Description:
3/4" - 10 X S 1/2" STUD Description of Sample Stock Location:
IB13J014 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
087 l
- Class / Procurement Level:
ITS/NSR j
l 1
General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor:
Hardware Specialty Co., Inc.
QA Requirements Imposed on Vendor:
PO# 050425; COC; Chemical and Physicals Reprinted on Hardware Specialty Co., Inc. letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
Date
/
4.,
Signature The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
,y.-
-w---
-,y-
Sh 9 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-29 Fastner
Description:
1" - 8 X 5 1/2" STUD Description of Sample Stock Location:
IB08J133 i
Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
HB B7
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor:
Park Hill Fasteners Inc., Hfg Harrison Bolt and Nut Co.,
Baltimore, Md.
QA Requirements Imposed on Vendor:
PO# 65968; Approved Vendor; and COC Licensee Representative:
l,
..d8 Date Signature f
The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
I
_.y.
m y-
Sh 10 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-31 Fastner
Description:
7/8" - 9 X 3 1/2" Bolt Description of Sample Stock location:
IB11N041 Material Specification as Documented by Licensee Records:
A325 Type 1 Head Marking (Specification and Manufacturer): Ng I
- Class / Procurement Level:
ITS General Plant Application (e.g., Pressure Boundary, Structural)
STRUCTURAL Vendor: Park Hill Fasteners, Inc.
QA Requirements Imposed on Vendor:
PO# 105018; COC; Commercial Grade Licensee Representative:
Signature
/'
Date f 4-((
t v
i sv The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Apendix B)
Sh 11 of 13 ATTACHMENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-33 Fastner
Description:
3/4" - 10 X 3 1/2" Heavy Hex Bolt l
Description of Sample Stock Location:
IB12L122
)
l Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
TB7 "Class / Procurement Level:
ITS/NSR i
General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY l
Vendor: Texas Bolt Co. (through Nova Machine Products Corp.)
QA Requirements Imposed on Vendor:
PO# 027775; CMTR; COC; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
I / 4, !A8 x.
Date Signature gw The sample ID# shall have a prefix that contains the licensee facility initials.
If appilcable, please provide an explanation for your classification system.
i (See Appendix B)
l 55 12 of 13 l
ATTACHMEN1 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-44 Festner
Description:
1" - 8 X 2 1/2 BOLT l
Description of Sample Stock Location:
IB12H062 i
Material Specification as Documented by Licensee Records:
A307GRA Head Marking (Specification and Manufacturer): (none) l
- Class / Procurement Level:
ITS/NSR 1
i General Plant Application (e.g., Pressure Boundary, Structural)
STRUCTURAL j
Vendor: A & A Bolt & Screw Co.
j QA Requirements Imposed on Vendor:
PO# 051167; Comercial Grade with COC Licensee Representative:
/!/4.,!A3 Signature
/-
0 Date
\\
The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
Sh 13 of 13 ATTACHHENT 1.A.1 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-47 Fastner
Description:
3/4" - 10 X 4 3/4 BOLT Description of Sample Stock Location:
1813I142 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
CP B7
- Class / Procurement level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: Hardware Specialty Co., Inc. (from Cardinal Fastener &
Specialty Co.)
QA Requirements imposed on Vendor:
C0C with reference to PO# 047699 and Haterial Type and Grade; 10 CFR 21; 10 CFR SO Appendix B Licensee Representative:
Date l,.f-[8 Signature i
-v The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
I
Sh 2 of 12 Sh I of 12 ATTACHMENT 1.A.2 HPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet 5/8" - 11 HEAVY HEX NUT
- ock Location:
IB08N071 is Documented by Licensee Records:
A194GR2H A193GR2H tion and Manufacturer):
NH 2H el:
ITS/NSR son (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY
- tural)
JNDARY Bolt Co.
rp.)
d on Vendor:
COC; Chemical and Physicals reprinted on Allied 10 CFR 21; 10 CFR 50 Appendix B endix 8 te:
d L
Date fJ l4. f 8
[f pg v-licensee facility classification (See Appendix B)
,,,----,------,,-.,--------.n
,<e- - -
v,e,
Sh 3 Cf 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-14 Fastner
Description:
5/8" - 11 HEAVY HEX NUT Description of Sample Stock Location:
IB08N071 Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer):
NH 2H
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: Allied Nut & Bolt Co.
l QA Requirements Imposed on Vendor:
PO# 053947; COC; Chemical and Physicals reprinted on Allied letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
Signature b
[-
Date l/
[8 The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
Sh 4 Cf 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample ID#
THI-17 Fastner
Description:
1/2" NUT Description of Sample Stock Location:
IB08N052 Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer):
21!T
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary. Structural)
PRESSURE BOUNDARY Vendor:
Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 014255; CMTR; COC (Documented on Texas Bolt letterhead);
10 CFR 21; 10 CFR 50, Appendix B Licensee Representative; b'
W
<h-Oate Signature u
o t
The sample ID# shall have a prefix that contains the licensee facility
- initials, i
If applicable, please provide an explanation for your classification system.
(See Appendix B)
Sh 5 of 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-18 Fastner
Description:
1/2" NUT Description of Sample Stock Location:
1808N052
)
Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer):
2HT
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY l
Vendor: Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 014255; CMTR; COC (Documented on Texas Bolt Co. letterhead);
10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
Signature Date
[,.28 The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
.y._
_.-.-my
.--_.r-m.,
r_
v
Sh 6 of 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS l
fastener Testing Data Sheet
- Sample ID#
THI-23 i
Fastner
Description:
5/8" - 11 NUT Description of Sample Stock Location:
IB10N113 Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer): 2H
- Class / Procurement Level:
ITS/NSR l
General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor:
Texas Bolt Co.
QA Requirements Imposed on vendor:
PO# 014255; Chemical and Physicals reprinted on Texas Bolt Co.
letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
f,/[4,, -
Signature
/i Date The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(Sea Appendix B)
Sh 7 of 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-24 Fastner
Description:
5/8" - 11 NUT Description of Sample Stock Location:
1810N113 Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specificaticr, and Manufacturer):
2H
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor: Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 014255; Chemical and Physicals reprinted on Texas Bolt letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
I [4, d
Signature 6
Date
..v g,-
The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
/
Sh 8 of 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheat
- Sampic ID#
THI-27 Fastner
Description:
3/4" - 10 HEAVY HEX NUT Description of Sample Stock Location:
1813J014 Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer):
JS 2H
~
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor:
Hardware Specialty Co., Inc.
QA Requirements Imposed on Vendor:
PO# 050425; COC; Chemical and Physicals reprinted on Hardware Specialty Co. letterhead; 10 CFR 21; 10 CFR SO Appendix B Licensee Representative:
f [4,!/k Signature
,,/ i
-(
Date The sample ID# shall have a prefix that contains the licensee faci!!ty initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) e
,_,,,y..,
Sh 9 cf 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-34 Fastner
Description:
3/4" - 10 HEAVY HU N'J.
l Description of Sample Stock Location:
1812L122 1
Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer):
2H
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vendor:
Texas Bolt Co. (through Nova Machine Products Corp.)
QA Requirements Imposed on Vendor:
PO# 027775; CMTR; COC; 10 CFR 21; 10 CFR 50 Appendix B i
Licensee Representative:
b Date
/ [4,.IX Signature fs 7-The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
_r-
,-,,.,_,7__
,,,,,__,,._,,,,,._,_,,_,.,.,g,___,
'Ja 10 of 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample ID#
THI-37 Fastner
Description:
3/4" - 10 NUT Description of Sample Stock Location:
IBilLO72 Material Specification as Documented by Licensee Records:
A194GR2H Head Harking (Specification and Manufteturer):
2HT
- Class / Procurement Level:
ITS General Plant Application (e.g., Pressure Boundary, Structural)
PRESSURE BOUNDARY Vandor: Texas Bolt Co.
QA Requirements Imposed on Vendor:
PO# 01S485; Chemicals and Physicals reprinted on Texas Bolt.
letterhead; 10 CFR 21; 10 CFR 50 Appendt B
Licensee Representative:
sr. - -
l [4.,g P2 Signature
/'
A-Date f
The sample ID# shall have a prefix that contains the licensee facility j
initials.
If ap.'. cable, please provide an explanation for your classification sys teni.
(See Appendir B) l l
/
Sh 11 cf 12 ATTACHMENT 1.A.2 IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-39 Fastner
Description:
1/2" - 13 HEAVY HEX NUT Description of Sample Stock Location:
IB08M033 Material Specification as Documented by Licensee Records:
A194GR2H Head Marking (Specification and Manufacturer):
NH 2H
- Class / Procurement Level:
ITS/NSR General Plant Application (e.g., Pressure Boundary, Struct-PRESSURE BOU$.
Vendor: Allied Nut & Bolt Co.
QA Requirements Imposed on Vendor:
PO# 042575; COC with reference to A194GR2H; PO# 042575 on Allied letterhead; 10 CFR 21; 10 CFR 50 Appendix B Licensee Representative:
![
A Date l/,-
Signature v, w i
The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
i (See Appena1x B) i
Sh 12 of 12
\\
ATTACHMENT 1.A.2
)
IMPORTANT TO SAFETY (ITS) NUTS Fastener Testing Data Sheet
- Sample ID#
THI-46 Fastner Descriptior :
1" - 8 HEX NUT Description of Sample Stock Location:
IB12H062 Material Specification as Documented by Licensee Records:
A563GRA Head Marking (Specification and Manufacturer):
(none) l
- Class / Procurement Level:
ITS/NSR i
General Plant Application (e.g., Pressure Boundary, Structural)
STRUCTURAL Vendor: A & A Bolt & Screw Co.
j QA Requirements Imposed on Vendor: PO# 051167; COC Licensee Representative:
Signature
/-
Date I
88 y
v a v -
a-The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) l l
I i
Sh 2 of 10 Sh 1 of 10 ATTACHMENT 1.8.1
./ STUDS 3
)RTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet i
l
- -1/8" - 7 X 3-5/8" Cap Screw
. k Location:
IB07N111 irds:
SAE GRADE 5
- Documented by Licensee Records:
SAE GRADE 5 I
- n and Manufacturer)
NITS
'e.g., Pressure Boundary Structural) itructural) 311 cation NITS Application i
\\
i vendor:
PO# 035614 (none)
/d Date te f /4.
I / 4,,.p
/
'I
-r ave a prefix that contains the licensee facility s the licensee facility provido an explanation for your classification
'r your cidssification (See Appendix B) 4 i
.. ~,..,
,. _., _.. _,...., _ - ~.,. _ _.
Sh 3 of 10 ATTACHMENT 1.B.1 NOT-!MPORTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-74 Fastner Desertption:
I" - 8 X 3-1/2" Cap Screw Description of Sample Stock Location:
1802E093 Material Specification as v'cumented by Licensee Records:
SAE GRADE 5
\\!
Head Marking (Specification and Manufacturer):
- Class / Procurement Level:
NITS i
General Plant Appilcation (e.g., Pressure Boundary, Structural)
NITS Application Vendor: General Electric Co.
QA Requirements Imposed on Vendor:
PO# 21044 (none)
Licensee Representative:
I[4,.
' b-Date Signature The sample 10# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendlx B)
_-,_-._.-_____,____,y
Sh 4 of 10 e
ATTACHMENT 1.B.1 NOT-IMPORTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-75 Fastner
Description:
3/4" - 10 X 3" Cap Screw Description of Sample Stock Location:
IB03E142 Material Specification as Documented by Licensee Records:
A325 Type i Head Marking (Specification and Manufacturer):
p
- Class / Procurement Level:
NITS General Plant Application (e.g., Pressure Boundary Structural)
NITS Application Vendor: Crane Co.
QA Requirements Iraposed on Vendor:
PO# 40372 (none)
Licensee Representative:
Date I 4- ((
Signature f-y
,s The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) 1 1
i
)
2 Sh 5 of 10 ATTACHMENT 1.8.1 NOT-!MPORTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample ID#
THI-78 Fastner
Description:
1/2" - 13 X 2-1/2" Cap Screw i
Description of Sample Stock Location:
1806L112 Material Specification as Documented by Licensee Records:
A193GRB7 Head Marking (Specification and Manufacturer):
JB7
- Class / Procurement Level:
NITS i
General Plant Appilcation (e.g., Pressure Boundary, Structural)
NITS Application Vendor: Mill Spec Fastener Corp.
QA Requirements imposed on Vendori PO# 22642 (none)
Licensee Representative:
I[4!8k Signature
/-
O, Date The sample ID# shall have a prefix that contains the licensee facility initials.
d If appilcable, please provide an explanation for your classification system.
(See Appendix B)
c**v.
t m.NWW2541 Sh 6 of 10 ATTACHMENT 1.B.1 NOT-IMPORTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-79 Fastner
Description:
5/8" - 11 X 3" Cap Screw Description of Sample Stock Location:
IE07IO62 Material Specification as Documented by Licensee Records:
A193GRB8 Head Marking (Specification and Manufacturer):
l P~
- Class / Procurement Level:
MITS General Plant Application (e.g., Pressure Boundary, Structural)
HITS Application Vendor: A & A Bolt & Screw Co.
QA Requirements Imposed on Vendor:
PO# 045519 (none)
Licensee Representative:
Date fg El-Signature a
gv i
The sample 10# shall have a prefix that contains the licensee facility initials.
)
If applicable, please provide an explanation for your classification system.
(See Appendix B) l
l Sh 7 of 10 ATTACHMENT 1.B.1 NOT-IMPORTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-80 Fastner
Description:
1/2" - 13 X 5" Cap Screw Description of Sample Stock location:
1814E143 Material Specification as Documented by Licensee Records:
SAE GRADE 5 Head Marking (Specification and Manufacturer):
/\\
- Class / Procurement Level:
NITS General Plant Application (e.g., Pressure Boundary, Structural)
NITS Appilcation Vendor: Pace & Stichter Supply Co.
QA Requirements Imposed on Vendor:
PO# 35414 (none)
Licensee Representative:
f Date,_l[4,!,f[
Signature
/
The sample ID# shall have a prefix that contains the licensee fact 11ty initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
,p
.-.-.-,:,,9 p.
m-
-.m..
m-y---, _, -...
7-.,-.
y-.
r- - -.-,-,,
,c
.m
,-y e
l Sh 8 of 10 i
ATTACHMENT 1.B.1 NOT-IMPORTANT TO SAFETY (NITS) BOLTS / STUDS Fastener Testing Data Sheet
- Sample 10#
THI-81 Fastner
Description:
1/2" - 13 X 4" Cap Screw Description of Sample Stock Location:
IB14E164 Material Spectftcation as Documented by Licensee Records:
SAE GRADE 5 I
Head Marking (Specification and Manufacturer): /\\
"Class / Procurement level:
NITS General Plant Application (e.g., Pressure Boundary, Structural)
NITS Application Vendor: Pace & Scichter Supply Co.
QA Requirements Imposed on Vendor:
PO# 35414 (none)
Licensee Representative:
/
Date
/,
,,9 [
Signature r.J. (
- ~..-- --
i w
The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
I 9
l 1
. _ _,. _ ~ _ _ _. - -. _. - _ _ _ -, _ _. _, - - _, _ _,., -...,
i Sh 10 of 10 Sh 9 of 10 ATTACNMENT 1.B.1 (TANT TO SAFETY (NITS) 80LTS/ STUDS S/ STUDS
'astener Testing Data Sheet
/2" - 13 X 2" Cap Screw
- k Location:
1A08D094 Documented by Licensee Records:
SAE GRADE 8 ds:
SAE GRADE 5
\\b on and Manufacturer):
\\
NITS i (e.g., Pressure Boundary, Structural) uctural)
NITS Appilcation ication Co.
on Vendor:
PO# 51227 (none)
Date l l4 EA
,hlg e
a-1e licensee racility i
sse provide an explanation for your classification i
'ur classification (See Appendix B) e 1
l Sh 1 of 9 ATTACHMENT 1.B.2 NOT-IMPORTANT TO SAFETY (NITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-84 Fastner
Description:
1/2" - 13 Heavy Hex Nut Description of Sample Stock Location:
18058015 Material Specification as Documented by Licensee Records:
A194 2H Head Marking (Specification and Manufacturer):
- Class / Procurement level:
NITS General Plant Application (e.g., Pressure Boundary, Structural)
NITS Application Vendor: Walworth Aloyco Div.
QA Requirements Imposed on Vendor:
PO# 40507 (none)
Licensee Representative:
l, (4,. !ff O
Date Signature The sample ID# shall have a prefix that contains the licensee facility initials.
j If applicable, please provide ar, explanation for your classifica'lon system.
(See Appendix B) 4
\\
Sh 2 of 9 ATTACHMENT 1.8.2 NOT-!MPORTANT TO SAFETY (NITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-85 Fastner
Description:
3/4" - 10 Heavy Hex Nut Description of Sample Stock Location:
IB05G085 Material Specification as Documented by Licensee Records:
A194 2H Head Marking (Specification and Manufacturer):
"Class / Procurement Level:
NITS General Plant Application (e.g., Pressure Boundary, Structural)
NITS Application (Handwheel Nut)
Vendor: Walworth Aloyco Olv.
QA Requirements Imposed on Vendor:
Licensee Representative:
Signature
/'
Date
/ [4 8
The sample ID# shall have a prefix that contains the licensee facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B)
Sh 3 of 9 ATTACHMENT 1.B.2 NOT-!MPORTANT TO SAFETY (NITS) NUTS Fastener Testing Data Sheet
- Sample ID#
THI-86 Fastner
Description:
7/8" - 9 Heavy Hex Nut Description of Sample Stock Location:
1803C132 Material Specification as Documented by Licensee Records:
A194 2H Head Marking (Specification and Manufacturer): {}
- Class / Procurement Level:
MITS General Plant Application (e.g., Pressure Boundary, Structural)
NITS Application Vendor:
Walworth Co.
QA Requirements Imposed on Vendor:
PO# 55242 (none)
Licensee Representative:
Date I[
[
Signature
/-
(
The sample ID# shall have a prefix that contains ti;e licenses facility initials.
If applicable, please provide an explanation for your classification system.
(See Appendix B) i I
t
-<s e,
Sh 5 of 9 Sh 4 of 9 ATTACHMENT 1.8.2
-IMPORTANT TO SAFETY (NITS) NUTS TS Fastener Testing Data Sheet 3/40 - 10 Heavy Hex Nut ek Location:
18070023 Documented by Licensee Records:
A194 2H on and Manufacturer): p NITS ucturaD (e.g., Pressure Boundary Structural)
NITS Appilcation i Vendor:
PO# 40705 (none)
I b
Dste l l4. ff u
i have a prefix that contains the licensee facility provide an explanation for your classification (See Appendix B) l 4
/
Sh 6 Gf 9 ATTACHMENT 1 5.2 NOT-!MPORTANT TO SAFETY (NITS) NUTS i
Fastener Testing Data Sheet
- Sample ID#
THI-89 Fastner
Description:
,1-1/2" - 8 Heavy Hex Nut Description of Sample Stock Location:
IB05E113 Material Specification as Documented by Licensee Records:
A194 2H Head Marking (Specification and Manufacturer):
- Class / Procurement Level:
NITS General Plant Appilcation (e.g., Pressure Boundary, Structural)
NITS Application
~
Vendor:
Interstate Fasteners Inc.
QA Requirements Imposed on Vendor:
PO# 13029 (none)
Licensee Representative:
l' Date I [
//
Signature
-.s fo-The sample ID# shall have a prefix that contains the licensee facility inttlais.
If applicable, please provide an explanation for your classification system.
(See Appendix B) j
i Sh 7 of 9 ATTACHMENT 1.B.2 NOT-!MPORTANT TO SAFETY (NITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-90 Fastner
Description:
3/4" - 10 Heavy Hex Nut Description of Sample Stock Location:
1B070103 Material Specification as Documented by Licensee Records:
A194 2H Head Marking (Specification and Manufacturer): h
- Class / Procurement Level:
NITS General Plant AppItcation (e.g., Pressure Boundary, Structural)
NITS Application Vendor: Walworth co.
QA Requirerrents Imposed on Vendor:
Licensee Representative:
Signature
/.
Date I/,8.8 The sample ID# shall have a prefix that contains the licensee facility initials.
If appilcable, please provide an explanation for your classification system.
(See Appendix B)
Sh 8 of 9 ATTACHMENT 1.8.2 NOT-!MPORTANT TO SAFETY (NITS) NUTS Fastener Testing Data Sheet
- Sample 10#
THI-91 Fastner
Description:
1/2" - 13 Heavy Hex Nut Description of Sample Stock Location:
1805E045 Material Specification as Documented by Licensee Records:
A194 2H Head Marking (Specification and Manufacturer): h
- Class / Procurement level:
MITS General Plant Application (e.g., Pressure Boundary, Structural)
NITS Application Vendor: Halworth Co.
QA Requirements Imposed on Vendor:
PO# 40527 (none)
Licensee Representative:
Signature J
Date Il,-[
The sample ID# shall have a prefix that contains the licensee facility initials.
t If appilcable, please provide an explane.tlon for your classification system.
1 (See Appendix B)
\\
Sh 1 of 8 IPPORTANT TO SAFETY (ITS) BOLTS / STUDS Data Summary Mechanical Analysis Chemical Analystsl ID#
Hardness UTS C 21 YS C
Mn P
S Si Mo Cr Ni
]
(psi)
(psi)
~~
~-
i TMI-1 Rc 31 144,032 131,687 0.41 0.88 0.01 4 0.031 0.24 0.22 1.01 TMI-5 Rc 32 135,093 120,082 0.462 0.93 0.021 0.015 0.26 0.15 1.03 TMI-7 Rc 31 143,877 133,673 0.398 0.86 0.023 0.023 0.28 0.15 0.88 i
I j
TMI-11 Rc 34 147,609 125,779 0.375 0.83 0.033 0.021 n.20 0.19 1.03 i
S TMI-15 Ra 60.5 100,500 72,000 0.077 1.90 0.034 0.025 0.52 2.68 17.27 11.98 j
(Rb 98.0)
TMI-19 Rc 29 120,449 101,713 0.448 0.81 0.029 0.01 4 i
~
i TMI-21 Rc 30 147,750 132,413 0.382 0.91 0.013
- 0. 01 9 0.21 0.17 0.94 I
1 TMI-25 Rc 33 142,715 123,637 0.443 0.85 0.027 0.022 0.22 0.19 0.99 Note:
UTS-ultimate tensile strength; YS-yield strength; C-carbon; fei-Manganese; P-Phosphorous; i
5-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Chromium; Ni-Nickel (for samples TMI-15 and TMI-79 only)
I The elements If sted apply to ASTM A193 87 or SA193 87 material. The elements to be reported for other materials tested shall conform to those reported in the applicable material specification.
Properties found out of specification shall be noted with an asterisk.
4 m
Sh 2 of 8 IMPORTANT TO SAFETY (ITS) BOLTS / STUDS Data Summary Mechanical Analysis Chemical AnalysisI C
P S
Si Mo Cr IDf Hardness UTS 0.27 YS
~~
~
~
~-
(psi)
(psi) i I
TMI-29 Rc 33 153,726 146,480 0.436 0.87 0.026 0.024 0.26 0.17 0.91 TMI-31 Rc 30 113,453*
87,349 0.358 0.70 0.01 9 0.01 7 TMI-33 Rc 31 144,578 133,534 0.42 0.89 0.015 0.027 0.24 0.22 0.97 i
0.025 0.01 8 TMI-44 Rb 98 73,469 69,387 l
l TMI-47 Rc 31 152,097 137,443 0.405 0.86 0.022 0.041 0.23 0.17 0.95 l
- A second sasple (TMI-32) was also tested for UTS and the value obtained was j
114,594 psi, still less than the required value of 120,000 psi.
Note:
UTS-ultimate tensile strength; YS-yield strength; C-carkm; m-Manganese; P-Phosphorous; S-Sulfur; St-Silicon; Mo-Molybdenum; Cr-Chromf em.
I The elements listed apply to ASTM A193 87 or SA193 B7 material. The elements to be reported for other materials tested shall conform to those reported in the applicable material specification.
Properties found out of specification shall be noted with an asterisk.
4
Sh 3 of 8 l
IM ORTANT TO SAFETY (ITS) NUTS Data Summary Mechanical Analysis Chemical Analysisl C
Mn P
S Si Mo Cr ID#
Hardness UTS 0.2% YS
~~
(psi)
(psi) 0.403 0.026 0.03?
TMI-4 Rc 27 0.40 0.012 0.035 TMI-13 Rc 25 0.01 2 0.032 TMI-14 Rc 25 0.40 l
0.442 0.01 8 0.028 TMI-17 Rc 33 1
TMI-18 Rc 34 0.428 0.01 8 0.029 0.401 0.025 0.017 TMI-23 Rc 33 4
TMI-24 Rc 33 0.41 0 0.023 0.01 6 0.486 0.024 0.040 TMI-27 Rc 29 Note:
UTS-ultimate tensile strength; YS-yield strength; C-carbon; Mn-Manganese; P-Phosphorous; S-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Chromium.
I The elements listed apply to ASTM A193 87 or SA193 87 material. The elements to be reported for other materials tested, shall conform to those reported in the applicable material specification.
Properties found out of specification shall be noted with an asterisk.
i
\\
l J
~
rn oo s
fi u
t o
da r
ec o
ti h
rf p
oi s
pc o
ee h
rp P
s e
P bl C-r a
oi e
t r s
e e
st n
ta a
nm M-o g
e n
me 8
a el M
lb f
ea.
o n
ck M
ei s i-4 hli S
Tpr h
n pe S
o
.at 2
4 7
b s
3 2
2 r
l ea 0
0 0
a ah c
itn S-0 0
0 r
a C
en tih S
2 2
2 a
t T
1 1
1 he mdi UN 0
0 0
tu ew gf 7t P-0 0
0 ne 8rd l
)
s eo oe S
t rr 3 pt T
s th 9eo I
y sC 1 rn 2( y l
A h-r a
dr See tYe n
lC sb m
nTu A
e ro eEs i ;
ohl mFu l
2 3
y-m tl hAS a
7 8
2 8
u 7
a cS c
4 3
4 0
Sn 8oh a
a i
Ye ts tot m
C-0 0
0 0
d 3
tTa e
- b 9mn A
D h
hy 1 ro T
C tl Aoi N
go ft A
nM Mna T
S e-T oc R
Y
)
ro Sci O
i tM A
f
% s s
l i M
(p 2
ol c I
s en tae i
0 l o hp s
i c yss y
si l
l nl p
,f 9
a ei pd o 2
n
)
tS ae A
A S
i tt T
s et dsu M
l U
p tS eeo T
a
(
a tt S
c m;
s d
A i
i r i sn n
tu ll u r
a s
lf ao e
h s
4 1
7 4
ul sif p
c e
3 3
2 9
u tr e
n SS nes e
t d
c c
c b
T -
et e c
r R
R R
R US mai n
i a
emt a
H l
r t
ere p
4 7
9 6
ep e
3 3
3 4
eho c
e ht r c
I I
I I
t top A
D M
M M
M o
I T
T T
T N
I 2
li i
- 1
!ll j
j*
,j il'
Sh 5 of 8 NOT-I W ORTANT TO SAFETY (NITS) BOLTS / STUDS Data Summary Mechanical Analysis Chemical Analysisl IDf Hardness UTS 0.27 YS
.C-
_Mo
_Cr
_NI Mm P
S Si TMI-72 Rc 28 120,478 84,055 0.431 0.025 0.017 TMI-73 Rc 31 136,690 113,566 0.398 0.031 0.013 TMI-74 Rc 31 124,605 98,843 0.381 0.024 0.021 TMI-75 Rc 32 140,688 118,927 0.369 0.83 0.009 0.023 TMI-78 Rc 31 136,500 127,000 0.359 0.82 0.014 0.01 7 0.30 0.23 1.11 TMI-79 Rh 90 88,265 64,285 0.005 1.50 0.029 0.010 0.44 18.05 9.%
TMI-80 Rc 28 113,052*
86,330*
0.335 0.021 0.01 9 TMI-81 Ec 31 137,014 129,856 0.31 0 0.013 0.016 Note:
UTS-ultimate tensfie strength; YS-yield strength; C-carbon; m-Manganese: P-Phosphorous; S-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Chromium; NI-Nickel (for samples TMI-15 and TMI-79 only) l The elements listed apply to ASTM A193 87 or SA193 87 material. The elements to be reported for other materials tested shall conform to those reported in the applicable material specification.
Properties found out of specification shall be noted with an asterisk.
Sh 6 of 8 l
NOT-Iff0RTANT TO SAFETY (NITS) BOLTS / STUDS Data Summary Mechanical Analysis Chemical Analysisl ID#
Hardness UTS 0.27. YS C
Mn P
S Si Mo Cr (psi)
(psi)
TMI-82 Rc 31 147,119 132,716 0.404 0.025 0.028 TMI-83 Rc 37 173,582 163,976 0.376 0.028 0.01 9 4
i i
1 Note:
UTS-ulttante tensile strength; YS-yield strength; C-carkn; ph-Manganese; P-Phosphoroes; l
S-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Chromium.
I The elements listed apply to ASTM A193 87 or SA193 87 material. The elements to be reported for j
other materials tested shall conform to those reported in the applicable material specification.
l Properties found out of specification shall be noted with an asterisk.
1 I
Sh 7 of 8 NOT-Iff0RTANT TO SAFETY (NITS) NUTS Data Susumery Mechanical Analysis Cheerical Analysisl C
Mrs P
S Si Mo Cr ID#
Hardness UTS 0.2% YS (psi)
(psi) 0.029 0.041 TMI-84 Rc 25 0.457 l
0.013 0.026 TMI-85 Rc 28 0.413 0.079 0.01 9 TMI-86 Rc 29 0.435 i
0.014 0.033 0.403 TMI-87 Rc 30 1
0.01 3 0.029 0.419 TMI-88 Rc 29 0.031 0.032 0.408 TMI-89 Rc 28 1
0.01 7 0.037 TMI-90 Rc 27 0.430 TMI-91 Rc 25 0.427 0.'027 0.038 J
l Note:
UTS-ultiente tensile strength; YS-yield strength; C-carbon; Mn-Manganese; P-Phosphorous; S-Sulfur; Si-Silicon; Mo-Molybden:sm; Cr-Chromium.
I The elements listed apply to ASTM A193 B7 or SA193 87 material. The elements to be reported for i
other materials tested shall conform to those reported in the applicable material specification.
Properties found out of specification shall be noted with an asterisk.
i
Sh 8 of 8 NOT-IM ORTANT TO SAFETY (NITS) NUTS Data Susunary Mechanical Analysis Chemical Analysisl ID#
Hardness UTS 0.2% YS C
Mn P
S Si Mo Cr (psi)
(psi) 0.032 p.034 0.406 TNI-93 Rc 25 1
)
i
,t P
i 1
l Note:
UTS-ultimate tensile strength; YS-yield strength; C-carbon; fei-Manganese; P-Phosphorous; S-Sulfur; Si-Silicon; F)-Molybdenen; Cr-Chromium.
)
l The elements listed apply to ASTM A193 87 or SA193 87 material. The elements to be reported for other materials tested shall conform to those reported in the applicable material specification.
Propertiesfoundoutofspecificationshallbenotedwithanasterisk.
j
--