i Mr. Charlis M. Duggar Septembsr 10, 1998

. Vice Prasid:nt Operations Entargy Operations, Inc.

P. O. Box B Killona, LA 70066

SUBJECT:

EVALUATION OF ENTERGY OPERATIONS, INCORPORATED, RESPONSE

.TO GENERIC LETTER 97-05 FOR WATERFORD STEAM ELECTRIC STATION, UNIT 3 (WATERFORD 3) (TAC NO. MA0508)

Dear Mr. Dugger:

i The Nuclear Regulatory Commission staff has completed its review of licensee responses to NRC Generic Letter (GL) 97-05, " Steam Generator Tube Inspection Techniques."

The focus of GL 97-05 was to verify that licensees' steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing bases. Entergy Operations, Inc. (EOl), submitted a response to this GL on March 17,1998, that included a description and technical basis for all inspection techniques used to size the depth of steam generator tube degradation at Waterford 3. The staff's review of this response did not identify any concerns with the steam generator tube inspection techniques employed at Waterford 3 l

1 that would Indicate that EOl is not in compliance with the current licensing basis for Waterford 3. This completes our review on this subject.

Sincerely, ORIGINAL SIGNED BY:

Chandu P. Patel, Project Manager Project Directorate IV-1 Division of Reactor Projects lil/IV Office of Nuclear Reactor Regulation Docket No. 50-382 cc: See next page DISTRIBUTION:

Docket File PUBLIC PD4-1 r/f CPatel JHannon CHawes.

TGwynn, RIV ) 1 w 7 ]-

EAdensam (EGA1)

ACRS I

mr 39 9

Document Name: WATA0508.LTR Pb/ DfV-1 OFC PM/_PDA-1 LA/PD4-1 NAME-CPNI/vw CHa N Iarmon DATE 9/ 9/98 h/20/98 1h98 F

COPY t YE),/NO YES/NO YES/NO

[h j

~ OFFICIAL RECORD COPY P;

a,-

_t 9809140205 980910 PDR ADOCK 05000392

)

P PDR

p uou g

UNITED STATES S

NUCLEAR REGULATORY COMMISSION f

WASHINGTON, D.C. N1

%*****/

September 10, 1998 Mr. Charles M. Dugger Vice President Operations Entergy Operations, Inc.

P.O.BoxB Killona, LA 70066

SUBJECT:

EVALUATION OF ENTERGY OPERATIONS, INCORPORATED, RESPONSE TO GENERIC LETTER 97-05 FOR WATERFORD STEAM ELECTRIC STATION, UNIT 3 (WATERFORD 3)(TAC NO. MA0508)

Dear Mr. Dugger:

The Nuclear Regulatory Commission staff has completed its review of licensee responses to NRC Generic Letter (GL) 97-05," Steam Generator Tube Inspection Techniques."

The focus of GL 97-05 was to verify that licensees' steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing bases. Entergy Operations, Inc. (EOI), submitted a response to this GL on March 17,1990, that included a description and technical basis for allinspection techniques used to size the depth of steam generator tube degradation at Waterford 3. The staff's review of this response did not identify any concerns with the steam generator tube inspection techniques employed at Waterford 3 that would indicate that EOl is not in compliance with the current licensing basis for Waterford 3. This completes our review on this subject.

Sincerely, hhh Chandu P. Patel, Project Manager Project Directorate IV-1 Division of Reactor Projects Ill/IV Office of Nuclear Reactor Regulation Docket No. 50-382 cc: See next page l

. 0 l

Mr. Charles M. Dugger Entergy Operations, Inc.

Waterford 3 i

cc:

Administrator Regional Administrator, Region IV i

Louisiana Radiation Protection Division U.S. Nuclear Regulatory Commission l

Post Office Box 82135 611 Ryan Plaza Drive, Suite 1000 Baton Rouge, LA 70884-2135 Arlington, TX 76011 Vice President, Operations Resident inspector /Waterford NPS Support Post Office Box 822 l

Entergy Operations, Inc.

Killona, LA 70066 P. O. Box 31995 l

Jackson, MS 39286 Parish President Council St. Chades Padsh i

Director P. O. Box 302 Nuclear Safety & Regulatory Affairs Hahnville, LA 70057 Entergy Operations, Inc.

l P. O. Box B Executive Vice-President

)

l Killona, LA 70066 and Chief Operating Officer j

l Entergy Operations, Inc.

l Wise, Carter, Child & Caraway P. O. Box 31995 P. O. Box 651 Jackson, MS 39286-1995 l

Jackson, MS 39205 l

Chairman j

General Manager Plant Operations Loulslana Public Service Commission Entergy Operations, Inc.