APPENDIX A Amersham Corporation Docket No. 99901105/88-01 NOTICE OF VIOLATION As a result of the inspection conducted on June 27-29, 1988, and in accordance with Section 206 of the Energy Reorganization Act of 1974 and its implementing regulation 10 CFR Part 21, the following violations were identified and categorized in accordance with NRC Enforcement Policy (10 CFR Part 2, Appendix C), 49 FR 8583 (March 8, 1984):
1.
Section 21.31 of 10 CFR Part 21 dated October 31, 1986, states, in part, "Each... corporation... subject to the regulations in this part shall assure that each procurement document for a... basic component... specifies, when applicable, that the provisions of 10 CFR Part 21 apply."
Contrary to the above, a review of purchase orders (P0) to vendors revealed that Amersham did not impose 10 CFR Part 21 requirements on P0 Nos. RPD-5261 (October 30,1987) to Computron; 5475 (December 22,1987) to General Latex and Chemical; 4929 (October 28,1987) to Morris and Broms; 2147 (September 18, 1985) to Grolex; 1056 (May 22, 1986) and 577 (September 21, 1987) to Lindberg Heat Treat; 578 (September 22, 1987), 610 (October 13,1987),1124 (March 4,1968), and 1261 (May 19,1988) to Advanced Heat Treat; 4734 (July 17, 1987), 4914 (August 28, 1987), and 5394 (December 10, 1987) to M.D. Machine; 4926 (September 2, 1987) and 4933 (September 3, 1987) to Nuclear Metals; 4572 (May 1,1987) and 5001 (September 8,1987) to Welders Supply; 5995 (March 23, 1988) to Harbor Tool Supply; 4491 (April 16,1987) to United Service; and 313 (April 3, 1987) and 5531 (December 14,1987)to ESSCO Calibration Laboratories.
(88-01-01) 8808190300 880812 01
..