Alabaina Power Company 600 North 18th Street PoM Office Box 2641 Birmin0 am, Alabama 35291-0400 h
Te!ephon 205250-1837 W. G. Hairston, Ill Se erVicePresident t;uclearOperations August 12, 1988
,3,,,,,3,,,,,c,nc,,,,,,
Docket Nos. 50-348 50-364 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Vashington, D.C.
20555 Gentlemen:
Joseph H. Farley Nuclear Plant - Units 1 and 2 Anticipated Transients Vithout Scrsm (ATVS)
By letter dated February 27, 1987, Alabama Power Comp y committed to provide to the NRC qualification test reports for the output relays of the AHSAC (ATVS Hitigating System Actuation Circuitry) system installed at Farley Nuclear Plant Units 1 and 2.
These test reports describe both the isolation and seismic qualification testing performed by Vestinghouse on the output relays that interface with the Reactor Protection Systeta.
Enclosed is a copy of VCAP-8687 Supp. 2-E68B Rev. O entitled, "0ualification of ATVS Hitigating System Actuation Circuitry in AMC0 Cabinet and Vall Mounted Hoffman Relay Enclosure (Combined Testing and Analysis)" (Proprietary) and a copy of VCAP-8587 Supp. 1-ESE-68B Rev. O entitled, "ATVS Hitigating Sy:: stem Actuation Circuitry in AMC0 Cabinet and l
Vall Mounted Hoffman Relay Enclosure" (Non-Proprietary).
(
l l
Also enclosed is a Vestinghouse authorization-letter, CAV-88-060.
l Proprietary Information Notice, and accompanying Affidavit. As VCAP-8687 contains information proprietary to Vestinghouse Electric Corporation, it
{
is supported by an affidavit signed by Vestinghouse, the ovner of the information. The affidavit' sets forth the basis on which the information may be withheld from public disclosure by the Commission and specifically addresses the considerations listed in paragraph (b)(4) of Section 2.790 of l
the Commission's regulations.
l Accordingly, it is respectfully requested that the information which is proprietary to Vestinghouse be withheld from public disclosure.in accordance with 10CFR Section 2.790 of the Commission's regulations.
Correspondence with respeat to the proprietary aspects of the l
Application for Vithholding er the supporting Vestinghouse Affidavit i
should reference CAV-88-060 and should be addressed to R. A. Viesemann, [g-[
l Hanager of Regulatory & Legislative Affairs, Vestinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania 15230-0355.
o (
1 CK O 48 t.ffR I
lNf PDC N31C.
l
[Nf
'p MtcPet pp
[
)
U. S. Nuclear Regulatory Commission August 12, 1988 Page 2 e-l If you have any questions, please advise.
1 Respectfully submitted, ALABAMA POWER COMPANY
- h.. f
.W V. G. Hairston, III VGH,III/BHW: dst-V8.40 Enclosure cc: Mr. L. B. Lot,g Dr. J. N. Grace Mr. E. A. Reeves Mr. V.11. Bradford W