Jump to navigation Jump to search
Forwards Westinghouse WCAP-11651, Analysis of Capsule U from Comm Ed,Byron Unit 1 Reactor Vessel Radiation Surveillance Program. Surveillance Capsule Test Results Do Not Indicate Any Significant Changes in Ref Temp
ML20151U113
Person / Time
Site: Byron Constellation icon.png
Issue date: 04/26/1988
From: Ainger K
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20151U117 List:
References
NUDOCS 8804290264
Download: ML20151U113 (1)


Text

r Commonwealth Edison One First Natonal Plaza, Chicago,18:nois 7

, Address Reply to- Post Offce Box 767 Chx.ago, lil'nois 60690 0767 April 26, 1988 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC. 20555

Subject:

Byron Station Unit 1 Reactor Vessel Radiation Surveillance Program NRC Docket No. 50-454 Gentlemen:

Enclosed is a Westinghouse Report entitled "Analysis of Capsule U from the Commonwealth Edison Byron Unit 1 Reactor Vessel Radiation Surveillance Program". This report is being submitted pursuant to 10 CFR 50, Appendix H. Surveillance capsule U was removed from the Unit I reactor vessel during the first refueling outage in the Spring of 1987. The surveillance capsule test results do not indicate any significant changes in the reference temperature, RTNDT, values projected for the reactor vessel. Please direct any questions regarding this matter to this office.

Very truly yours, K. A. Ainger Nuclear Licensing Administrator i

/klj cc: NRC Resident Inspector-Byron encl.

4544K 00

\ .\

k 0804290264 080426 PDR ADOCK 05000454 p DCD u__