1 OPERATING DATA REPORT Dockot,No.:
50-309 Dato:
02/Aug/C8 Completed By:
D.A. Rivard Telephone 207-882-6321 i
1.
Unit Name.......................................
Maine Yankee 2.
Reporting Period................................
July 1980 3.
Licensed Thermal Powar (MWt)....................
2630 4.
Nameplate Rating (Gross MWe)....................
864 5.
Design Electrical Rating (Net MWe)..............
825 6.
Maximum Dependable Capacity (Gross MWe).........
850 7.
Maximum Dependable Capacity (Net MWe)...........
810 j
8.
If Changes in Capacity Ratings (Items Number 3-7) l Since Last Report, Give Reasons:
NO CHANGE 9 I
i 9.
Power Level to Which Restricted, if Any (Net MWe)
- 10. Reasons for Restrictions, if Any l
THIS MONTH YEAR-TO-DATE CUMULATIVE t
- 11. Hours In Reporting Period 744.00 5.111.00
- 12. Number of Hours Reactor Was Critical...........
744.00 5.094.92 110.948.24 [
- 13. Reactor Reservu Shutdown Hours..................
0.00 0.00 0.00 ;
- 14. Hours Generator On-line..
744.00, 5.001.78 107.836.86
- 15. Unit Reserve Shutdown Hours..................
0.00 0.00 QtqQ_.
- 16. Gross Thermal Energy Generated (MWH)........
1.949.589.00 13.279.028.00 247.639.359.00 i
- 17. Gross Electrical Energy Generated (MWH)........
601.300.00 4.1Q7 260.00 81.040.990.00 i 3
- 18. Net Electrical Energy
[
Generated (MWH)........
581.439.00 4g!!5.946.00 77.486.918.00 l
- 19. Unit Service Factor......
100.00 99.43 78.27 f
- 20. Unit Availabilty Factor.,
100.00 99.43 78.27 !
d
- 21. Unit Capacity Factor i
(Using MDC Net)........
96.40
,_ 97.01 70.94_j
- 22. Unit Capacity Factor (Using DER Net)........
94.73 95.24 69.16
- 23. Unit Forced Outage Rate..
0.00 0.ql_
7.02_<
I
- 24. Shutdowns Scheduled Over Next 6 Months
?
Date Type Duration
_12/15/8B REFUELING OUTAGE e WEEKS
- 25. If Shutdown at End of Report Period, Estimated Date of Startup N/A e
t i
i I
L
Dockot*No 50-009 Unit Name:
Maine Yankee Date:
02AUG1980 Completed Dy D.A.
Rivard Telephone:
207-082 o321 Report Month: July, 1983 NARRATIVE
SUMMARY
OF OPERATING EXPERIENCES At the beginning of the month, the unit was cperating at 100% power.
On 22 July, thermal oower was reduced from 2630 MW to 2600 MW for operating flexibility during coastdown.
The unit was operated at 99% power f or tha remainder of the month.
AVfRAGE DAILY UNIT POWER LEVCL FOR JULY 1988 Docket No.:
50-309 tini t t Maine Yankee Date:
03/Aug/88 Completed py D.A.
Rivard Telephones, 207-882-6321 t
r Day Avg. Daily Power Level Day Avg. Daily Power Level l (MWe-Net)
(MWe-Net) 1 792 16 782 2
792 17 783 3
792 1
781 4
790 780 i
5 791
)
782
{
t 6
788
?'
782 i
r 7
788 22 781-t 8
785 23 774 l
9 783 24 776 10 783 25 774 11 783 26 775 12 781 27 774 13 781 20 774
....e...............
k 14 781 29 773 15 782 30 772 31 773 4
r 6
i h
..s.
UNIT SHUTDOWNS ArD POWER REDUCTIONS Docket No.:
50-304 FOR JULY 1988
- Unit Mcinn Yenken Date:
03/Aug/88 Completed By:
D.A.
Rivard Telephone:
207-882-6321 Page:
1 of 1 Number Date Type (1)
Duration (Hours)
Reason (2)
Method (3)
LER #
System Code (4)
Component Code (5)
Cause and Corrective Action 1
1.
TYPE:
2.
REASON: (cont) 4.
SYSTEM CODE:
(F)orced F-Administrative Exhibit G-Instructions (S)cheduled G-Operational Error for Preparation of Data H-Other (Explain)
Entry Sheets for 2.
REASON Licensee Event Report A-Equipment Failure 3.
METHOD:
(LER) File (NUREG.01612 E-Maintenance or Test 1-Manual C-Refueling 2-Manual Scram 5.
COMPONENT CODE:
D-Regulatory Restriction 3-Automatic Scram Exhibit I-Same scurce E-Operator Training h 4-Other ( E:: p l ai n )
as above.
License E:: amination l
MaineYankee f tLIABL E ELECTA' CITY FOR MA!NE SiNCE 1972 1
EDISON DRIVE. AUGUSTA. M AINE 04330. (207) 622 4868 l
l August 10, 1988 HN-88-78 G0H-88-210 Office of Resource Management United States Nuclear Regulatory Commission Washington, D. C.
20555 Attention:
Document Control Desk Referencos:
(a) Licensa No. OPR-36 (Docket No. 50-309)
(b) NUREG-0020, Licensed Operating Reactors Status Summary Report
Subject:
Maine Yankee Monthly Statistical Report Gentlemen:
Enclosed you will find the Monthly Statistical Report for the Maine Yankee Atomic Power Station for July, 1988.
Very truly yours, HAINE YANKEE Aj 0/)V G. D. Whittier, Manager Nuclear Engineering and Licensing G0H/bjp Enclosure cc: Mr. Richard H. Hessman Mr. Hilliam T. Russell Mr. Patrick H. Se vs Mr. Cornelius F.
olden 92'$
'f, 0124L-SLH
.