Text
,
gym
.6 FEB 051966 Westinghouse Electric Corporation
%TTN: Mr. E. P. Loch, Manager Columbia Plant Nuclear Fuel Division-Drawer R Columbia, SC 29250
' Gentlemen:
SUBJECT:
REPDRT NO.' 70-1151/86-01 On January 7-10, 1986, NRC inspected activities authorized by NRC License No. SNM-1107 for your Westinghouse Nuclear Fuel Division facility.
At the conclusion of the inspection, the findings were discussed with those members.of your staff identified in the enclosed inspection report.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities in progress.
'Within the scope of the inspection, no violations or deviations were identified.
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Federal Code of Regulations, a copy of this letter and its enclosures will be placed in the NRC's Public Document Room.
Should you have any questions concerning this letter, please contact us.
Sincerely, Kenneth P. Barr, Chief Nuclear Materials Safety and Safeguards Branch Division of Radiation Safety and Safeguards
Enclosure:
Inspection Report No. 70-1151/86-01 bec w/ enc 1:
(See page 2) 0602100369 060205
{DR ADOCK 07001151 PDR i '
1*Go '7
s i -
Westinghouse Electric Corporation 2
bec w/ encl:
' p K B. Matthews, EPLB, IE-HQS EP Section File Document Control Desk State-of. South Carolina
.bcc w/o enc 1:
A cense Fee Management. Branch RI}
RII R
RII RII NKreh:cdg M Y cAlpine TRDe ker DMCollins able 01/3//86 01/4/86 q,1///86 02Nr /86 UA/ur/86