e Alibama Power Company 600 North 10th Strut Post office Box 2641 Birmingham Alabama 35291-0400 1

Telephone 205 250-1835 R. P. Mc Donald Senior Vice President Mghgg]3 ggegp the southctn ekK:tre system Docket No. 50-364 10CFR50.36 April 20, 1988 U. S. Nuclear Regulatory Comission Attention: Document Control Desk Washington, D. C.

20555 Gentlemen:

Joseph M. Farley Nuclear Plant - Unit 2 Steam Generator Eddy Current Inspection As required by Section 4.4.6.5.b of the Farley Nuclear Plant Unit 2 Technical Specifications, Alabama Power Company herewith reports the results of eddy current testing conducted during the fifth refueling outage.

During the fifth refueling outage of Farley Unit 2 all non-plugged tubes in all three steam generators were inspected. The results are summarized below:

STEAM NUMBER OF NUMBER NUMBER GENERNIDR TUBES INSPECTED DEGRADED DEFECTIVE F*

A 3264 26 13 12 B

3275 23 35 18 C

3250 86 61 58 yh

' I 8804280292 880420 PDR ADOCK 05000364 P

DCD

O. S. Nuclear Regulatory Comnission April 20, 1988 Page 2 l

Table I (attached) identifies the tubes with imperfections by location, percent of wall-thickness penetration where applicable, RPC results where applicable and notes those plugged.

Respectfully submitted, A

ALABAMA PW ER 7

m R. P. Mcdonald RPtVCDPical-V4 Attachment cc Mr. L. B. Long Dr. J. N. Grace Mr. E. A. Reeves Mr. W. H. Bradford i

l i

3 4

4

TABLE I DIS'mHCE MhLL REFERENCE FI M

'!HICIGESS S/G MON COL POINF REFEIUINCE PDE'mATION RPC

  • VOL'mGE PLUGGED A

9 12 SPH4 47.3 46%

YES A

10 13 SPH4 48.9 44%

YES A

35 17 SPH1 71%

YES A

21 42 SPH2 0.7 DI SAI SAT.

YES A

30 44 SPH1 71%

YES A

32 47 TSH DI MAI UNSAT.

YES A

40 55 SPH1 66%

YD-A 2

56 SPH3 DI SAI WSAT.

YE5 A

43 58 SPH2 64%

YES A

5 73 TSH DI MAI WSAT.

YES A

4 74 TSH DI MAI WSAT.

YES A

3 78 TSH DI MAI WSAT.

YES A

6 92 SPH1 53%

YES A

7 4

SPH5 33%

NO A

21 10 TSH 0.9 35%

NO A

35 25 AVB2 4.7 21%

to A

24 30 AVB4 6.3 23%

NO A

32 46 AVB2 3.7 21%

NO A

37 47 SPH1 28%

NO A

28 52 AVB2 23.7 34%

NO A

28 52 AVB2 3.5 32%

to A

31 52 SPH1 DI SAI SAT.

N)

A 31 52 AVB2 2.7 25%

to A

28 57 AVB2 2.2 33%

to A

28 57 AVB2 23.4 32%

to A

28 57 AVB4 4.1 28%

to A

30 58 SPH7 28.6 20%

to A

30 58 Avs2 24.6 22%

to A

25 61 AVB4 3.2 21%

to A

25 61 SPH7 28.1 24%

NO A

25 61 AVB2 18.7 38%

to A

25 61 AVB2 1.2 31%

NO A

41 61 AVB2 34.6 28%

NO A

29 62 AVB2 3.0 28%

NO A

29 62 AVB2 22.2 33%

to A

29 63 AVB2 1.5 25%

to A

29 63 AVB2 23.0 25%

to A

21 65 AVB2 1.1 27%

NO A

38 72 SPH2 36%

NO A

36 75 SPH7 33.0 21%

NO A

33 22 SPH1 DI MAI SAT.

to A

40 40 SPHI DI SAI SAT.

NO A

34 51 SPH1 DI SAI SAT.

?O A

40 69 SPH1 DI SAI SAT.

to A

19 86 SPH1 DI SAI SAT.

to A

14 92 SPH1 DI SAI SAT.

to A

6 2

SPH2 DI SAI SAT.

10 l

A 39 36 SFH2 DI SAI SAT.

hO A

6 88 SPH2 DI SAI SAT.

to A

32 46 AVB2 27.0

< 20 to A

29 52 AVB2 3.6

< 20 to i

Page 1 of 10

'InBIE I DISTANCE NEL REPElWNCE FI M

'IIIICDESS S/G 3G COL POINT REPEIGHCE PDer114ATICN RPC VOUIRGE PWOGED A

19 74 Avs2 13.9

< 20 NO A

30 58 Avs2 1.7

< 20 NO A

41 61 AVB2 3.7

< 20 NO A

21 65 AVB2 16.0

< 20 NO A

21 65 SPH7 25.0

< 20 NO A

29 62 SPH7 29.2

< 20 NO A

8 86 SPC3

< 20 NO A

9 7

SPC5

< 20 NO A

16 51 SPC5

< 20 NO A

31 58 SPC6 33.4

< 20 NO A

17 18 SPC7

< 20 NO A

17 18 TSH 4.5

< 20 NO A

17 18 TSH 3.0

< 20 NO A

6 33 SPC7

< 20 NO A

22 26 SPH1 36.2

< 20 NO A

34 34 SPH1

< 20 NO A

36 38 SPH1

< 20 NO A

40 38 SPH1

< 20 NO A

33 37 SPH3 25.9

< 20 No A

19 11 SPH5

< 20 NO A

19 40 SPH5

< 20 No A

21 41 SPH5

< 20 No A

20 11 SPH6

< 20 NO A

36 40 SPH6

< 20 No A

30 83 SPH6

< 20 NO A

41 38 SPH7

< 20 No A

15 22 TSC 1.6

< 20 NO A

9 12 TSH 4.0

< 20 No A

11 19 TSH 4.8

< 20 NO A

14 20 TSH 1.6

< 20 No A

15 23 TSH 1.5

< 20 No A

15 34 TSH 3.4

< 20 NO A

29 41 TSH 1.4

< 20 NO A

32 48 TSH 5.7

< 20 NO A

44 56 TSH 3.4

< 20 No A

44 59 TSH 1.4

< 20 No A

9 13 TEH 16.3 80%

NO (F*)

A 15 15 TEH 10.7 98%

NO (F*)

A 15 31 TEH 15.8 87%

NO (F*)

A 12 40 TEH 16.5 78%

NO (F*)

A 13 40 TEH 18.6 87%

NO (F*)

A 15 48 TEH 4.5 69%

NO (F=)

i A

13 52 TEH 13.5 50%

NO (F*)

A 7

59 TEH 16.5 82%

NO (F*)

A 10 60 TEH 3.2 58%

NO (F*)

A 13 61 TEH 1.2 41%

No (F*)

A 13 71 TEH 13.5 53%

NO (F*)

A 16 84 TEH 17.4 67%

NO (F*)

t A

16 84 TEH 4.1 42%

NO (F*)

B 12 3

SPH2 48%

YES B

14 5

SPH2 52%

YES B

17 7

SPH1 65%

YES Page 2 of 10 l

MBIA I DISBNCE MLL REFERENCE FIOl

'Ill!CIGESS S/G N3f COL POIlfr REFERENCE PDEmtATIN RPC VOLM GE PWGGED B

17 7

SPH5 57%

YES B

8 9

EH 20.3 62%

YES B

12 15 SPH1 51%

YES B

34 16 SPH1 89%

YES B

24 18 SPH1 48%

YES B

37 38 TSH 54%

YES B

41 38 TSH DI MAI WSAT.

YES B

46 42 SPH1 72%

YES B

42 43 SPril 58%

YES B

2 55 SPH1 66%

YES B

33 55 TEH 20.4 Di MAI WSAT.

YES B

21 56 TEH 20.4 67%

YES B

22 56 TER 20.4 DI SAI WSAT.

YES B

25 57 TEH 20.5 45%

YES B

42 58 SPH7 36.0 41%

YES B

18 60 SPH2 49%

YES B

39 62 AVB4 3.8 40%

YES B

43 62 SPH2 72%

YES B

14 63 TEH 19.8 84%

YES B

41 66 SPH1 DI SAI WSAT.

YES B

25 72 SPH2 49%

YES B

34 76 SPH2 60%

YES B

21 78 SPH2 86%

YES B

32 78 SPH2 DI SAI WSAT.

YES B

4 80 SPH1 84%

YES B

7 81 SPH2 71%

YES B

18 81 SPH5 DI MAI WSAT.

YES B

12 82 TEH 20.3 76%

YES B

3 84 SPH1 58%

YES B

17 84 SPH1 66%

YES B

18 86 SPH1 66%

YES B

8 90 SPH1 DI SAI WSAT.

YES B

5 91 SPH1 64%

YES B

20 6

SPH3 DI SAI SAT.

to B

3 15 TSH 2.8 33%

NO B

34 19 SPH1 DI SAI SAT.

to B

14 21 TSH 3.1 31%

NO B

29 27 AVB2 2.8 32%

to B

29 27 AVB2 24.4 28%

to B

41 40 SPH1 DI SAI SAT.

10 B

39 43 SPH7 34.8 35%

No B

39 44 AVB2 6.3 24%

to B

39 44 SPH7 34.8 29%

to B

39 53 AVB2 5.8 31%

to B

39 53 SPH7 34.8 37%

to B

38 56 AVB2 5.4 28%

to l

B 38 56 AVB4 4.0 23%

to l

B 38 56 AVB2 34.1 37%

to B

28 57 AVB2 24.8 31%

NO B

28 57 AVB2 4.3 33%

to B

28 57 AVB4 3.7 20%

to B

38 58 SPH7 33.7 28%

No Page 3 of 10

F BBLE I I

DISBNCE MhLL REFERENCE FRCM

'! HIC 10ElSS S/G RCBF COL POINF REFERENCE PBelMATICH RPC

  • VOLMGE'
  • FWGGED B

38 58 AVB2 5.6 24%

to B

42 58 AVB2 6.0 31%

NO B

39 62 AVB2 34.9 29%

NO

[

B 41 62 SPH1 35%

No i

B 4

67 SPH2 DI SAI SAT.

to B

7 68 SPC6 36%

NO B

19 72 SPH2 30%

NO B

33 78 SPH1 DI SAI SAT.

to B

2 81 SPH1 DI SAI SAT.

NO B

30 81 SPH1 DI SAI SAT.

to B

2 84 SPH3 DI SAI SAT.

to B

6 88 SPH1 DI SAI SAT.

NO B

6 92 SPH2 DI SAI SAT.

NO B

3 93 SPH1 DI SAI SAT.

to B

40 32 AVB2 5.8

< 20 to r

B 39 43 AVB2 6.0

< 20 NO B

39 44 AVB2 6.6

< 20 NO B

24 55 AVB2 3.2

< 20 NO 4

B 24 55 AVB2 19.7

< 20 No t-B 13 38 SPC1

< 20 to B

13 38 TSC 1.9

< 20 NO B

39 51 SPC1

< 20 NO B

15 67 SPC3

< 20 No B

15 67 SPC7

< 20 to B

19 84 SPC3

< 20 No B

9 66 SPC5

< 20 NO B

13 84 SPC5

< 20 to B

9 93 SPC5

< 20 to B

10 4

SPC6

< 20 NO B

20 81 SPC6

< 20 to B

10 89 SPC6

< 20 to B

14 89 SPC6

< 20 to B

10 92 SPC6

< 20 to B

12 85 SPC7

< 20 to B

15 85 SPC7

< 20 to B

13 87 SPC7

< 20 to B

11 90 SPC7

< 20 to B

5 77 SPH2

< 20 NO B

22 82 SPH2

< 20 NO B

31 82 SPH2

< 20 to B

21 62 SPH2

< 20 NO B

13 66 SPH5

< 20 to i

B 41 61 SPH6

< 20 NO B

30 80 SPH6

< 20 to B

42 64 SPH7

< 20 to B

35 75 SPH7 36.1

< 20 to l

B 12 21 "SC 1.4

< 20 to B

11 2

TSH 1.1

< 20 to 1

B 4

10 TSH 1.7

< 20 to B

18 22 TSH 1.6

< 20 to B

17 23 TSH 3.6

< 20 to B

13 25 TSH 2.9

< 20 to Page 4 of 10

TABLE I DISTANCE NALL REFERENCE FROM

'IYIICKNESS S/C ROW COL POINF REFERENCE PENETRATION RPC VOUDGE PLUGGED B

18 43 TSH 3.3

< 20 NO B

9 46 TSH 3.9

< 20 NO B

30 78 TSH 1.3

< 20 NO B

30 78 TSH 5.0

< 20 NO B

15 11 TEH 1.4 94%

NO (F*)

B 14 13 TEH 2.5 86%

NO (F*)

B 23 14 TEH 4.6 40%

NO (F*)

B 15 15 TEH 1.0 57%

NO (F*)

B 17 15 TEH 2.1 79%

NO (F*)

B 25 16 TEH 2.6 57%

NO (F*)

B 10 21 TEH 6.4 89%

NO (F*)

B 21 24 TEH 5.1 73%

1D (F*)

B 39 36 TEC 6.6 91%

NO (F*)

B 42 36 TEC 4.9 92%

NO (F*)

B 41 39 TEH 15.2 64%

NO (F*)

B 41 39 TEH 18.4 61%

NO (F*)

B 41 39 TEH 19.3 89%

NO (F*)

B 28 43 TEC 19.2 93%

NO (F*)

B 46 48 TEH 18.0 73%

10 (F*)

B 46 48 TEH 18.5 45%

NO (F*)

B 44 55 TEC 4.7 58%

NO (F*)

B 18 68 TEC 6.6 44%

NO (F*)

B 28 76 TEC 5.5 97%

NO (F*)

B 13 78 TEH 14.3 NDD SAI

?O (F*)

B 19 78 TEC 4.7 81%

NO (F*)

B 19 78 TEC 6.6 84%

NO ( F* )

B 21 79 TEC 17.3 69%

NO (F*)

C 13 4

SPH5 DI SAI UNSAT.

YES C

17 5

SPH1 DI MAI UNSAT.

YES

[

C 14 11 SPHS DI SAI UNSAT.

YES l

C 23 11 TEH 19.7 DI MAI UNSAT.

YES C

28 15 SPH3 42%

YES C

8 16 SPH1 64%

YES C

23 16 TEH 19.7 DI MAI UNSAT.

YES C

28 16 Spill 73%

YES C

20 22 TEH 20.1 DI MAI UNSAT.

YES C

39 22 SPH7 44%

YES C

24 26 TEH 20.0 DI MAI UNSAT.

YES C

44 34 SPH4 DI SAI UNSAT.

YES C

44 36 SPH1 48%

YES l

C 45 36 SPH1 DI SAI UNSAT.

YES l

C 10 39 TEH 20.0 DI MAI UNSAT.

YES C

7 40 TEH 20.0 DI MAI UNSAT.

YES l

C 28 42 SPH1 76%

YES C

35 42 SPH1 62%

YES l

C 11 45 TEH 20.1 DI MAI UNSAT.

YES C

7 47 TEH 20.1 DI SAI UNSAT.

YES l

C 6

48 SPH1 57%

YES l

C 9

48 TEH 20.1 79%

YES l

C 31 48 SPH1 DI SAI UNSAT.

YES i

C 8

51 SPH1 DI SAI UNSAT YES l

C 12 51 TEH 20.5 DI MAI UNSAT.

YES j

Page 5 of 10 l

l i

er TABLE I DISTANCE NALL REFERENCE FROM

'IYlICKNESS S/G RON COL POINP REFERENCE PENE'IRATION RPC VOLTAGE PLUG"g C

36 51 SPH1 71%

YES C

37 51 SPH1 59%

YES C

36 53 SPH1 72%

YES C

32 55 SPHI 65%

YES C

37 55 SPH1 69%

YES C

34 61 SPH1 70%

YES C

37 62 SPH1 DI SAI UNSAT.

YES C

26 63 SPH1 63%

YES C

14 65 TSC 1.4 59%

YES C

40 65 SPH1 DI SAI UNSAT.

YES C

21 67 SPH1 DI SAI UNSAT.

YES C

13 68 SPH1 DI SAI UNSAT.

YES C

20 69 SPH1 DI SAI UNSAT.

YES C

34 69 SPH1 DI SAI UNSAT.

YES C

41 69 SPH1 71%

YES C

8 70 TEH 20.0 DI MAI UNSAT.

YES C

14 71 SPH1 57%

YES C

7 72 TEH 20.0 DI MAI UNSAT.

YES C

14 72 SPH1 DI MAI UNSAT.

YES C

3 73 SPH2 78%

YES C

32 75 SPH1 67%

YES C

20 77 SPH3 71%

YES C

28 77 SPH4 DI SAI UNSAT.

YES C

5 79 TSH DI MAI UNSAT.

YES C

3 80 Tsa 78%

YES C

8 80 TEH 19.8 DI MAI UNSAT.

YES C

22 60 SPH1 70%

YES C

22 81 SPH1 DI SAI UNSAT.

YES C

9 82 TEH 20.8 DI MAI UNSAT.

YES C

19 84 SPH1 DI SAI UNSAT.

YES C

23 84 SPH1 85%

YES C

5 89 SPH1 DI SAI UNSAT.

YES C

12 89 SPH1 72%

YES C

19 90 SPH1 59%

YES C

4 92 SPH1 DI SAI UNSAT.

YES C

7 92 SPH1 72%

YES C

6 1

SPH1 DI MAI SAT.

NO C

14 8

SPH1 DI SAI SAT.

NO C

29 12 SPH7 24%

NO C

18 14 SFH1 DI SAI SAT.

NO C

30 14 TSH 38.7 25%

NO C

14 24 SPH2 DI SAI SAT.

NO C

33 24 SPH1 DI SAI SAT.

NO C

38 24 SPH1 DI SAI SAT.

NO C

37 25 SPH1 DI SAI SAT.

NO C

34 33 SPH2 35%

NO C

33 35 TSH 2.2 25%

NO C

39 35 AVB2 32.3 24%

NO C

32 36 SPH6 32%

NO C

33 38 SPH1 DI SAI SAT.

NO C

39 39 SPH2 DI SAI SAT.

NO C

36 43 SPH1 DI SAI SAT.

NO Page 6 of 10

l TABLE I DISTANCE NM.L REFERENCE FROM

'IHICKNESS S/G ROW COL POINT REFERENCE PENETRATION RPC VOLTAGE PLUGGED C

40 43 SPH1 DI SAI SAT.

to C

36 46 SPH1 DI SAI SAT.

NO C

18 47 SPH1 33%

NO C

45 47 SPH1 DI SAI SAT.

NO C

42 48 SPH4 36%

NO C

4 51 SPH1 DI MAI SAT.

NO C

28 51 SPH1 DI SAI SAT.

NO C

42 51 SPH4 DI SAI SAT.

NO C

34 53 SPH1 DI SAI SAT.

NO C

29 54 SPH1 DI SAI SAT.

NO C

35 55 SPH6 DI SAI SAT.

NO C

38 58 SPH6 22%

NO C

41 59 SPH2 DI SAI SAT.

NO C

45 59 SPH2 DI SAI SAT.

10 1

C 35 60 SPH1 DI SAI SAT.

NO l

C 29 62 AVB2 3.5 29%

NO C

33 62 SPH1 DI SAI SAT.

NO C

38 62 SPH1 DI SAI SAT.

NO C

33 63 SPH1 DI SAI SAT.

NO C

18 64 AVB2 21%

NO l

C 18 64 AVB2 12.0 24%

NO C

37 64 SPH1 DI SAI SAT.

NO C

41 64 SPH1 DI SAI SAT.

to l

C 42 64 SPH1 DI SAI SAT.

10 i

C 38 65 SPH1 DI SAI SAT.

NO C

42 65 SPH1 DI SAI SAT.

NO C

3 66 SPH1 DI SAI SAT.

NO C

16 68 SPH1 DI SAI SAT.

to C

27 68 SPH1 DI SAI SAT.

NO I

C 4

69 SHP2 DI SAI SAT.

to C

34 70 SPH1 DI SAI SAT.

NO i

C 35 70 SPH1 DI SAI SAT.

to I

C 35 70 SPH2 DI SAI SAT.

NO l

C 33 71 SPH1 DI SAI SAT.

NO l

C 38 71 SPH1 DI SAI SAT.

NO C

20 72 SPH1 DI MAI SAT.

to C

19 73 SPH1 DI SAI SAT.

to C

35 73 SPH1 DI MAI SAT.

NO C

16 74 SPH1 DI SAI SAT.

NO l

C 34 74 SPH1 DI SAI SAT.

NO C

35 74 SPH1 DI MAI SAT.

FD C

5 75 SPH1 DI SAI SAT.

NO C

16 75 SPH1 DI MAI SAT.

NO C

20 75 SPH1 DI MAI SAT.

10 C

33 75 SPH6 DI SAI SAT.

NO C

34 75 SPH2 DI SAI SAT.

NO l

C 35 76 SPH1 DI SAI SAT.

10 C

26 77 SPH1 DI SAI SAT.

10 C

28 77 SPH1 DI MAI SAT.

to C

32 77 SPH2 DI SAI SAT.

to C

30 79 SPH4 DI SAI SAT.

NO C

24 80 SPH1 DI SAI SAT.

NO Page 7 of 10 i

TABLE I DISTANCE MALL REFERENCE FROM THICKNESS S/G RON COL POINF REFERENCE PENETRATION RPC VOLTAGE PLUGGED C

5 81 SPH2 DI SAI SAT.

NO C

15 83 SPH1 DI SAI SAT.

NO C

17 83 SPH1 DI SAI SAT.

NO C

20 83 SPH2 DI SAI SAT.

NO C

25 83 SPH5 22%

NO C

15 84 SPH2 DI SAI SAT.

NO C

29 84 SPH1 DI SAI SAT.

NO C

19 85 SPH2 DI SAI SAT.

NO C

20 85 SPH1 DI SAI SAT.

NO C

21 85 SPH1 DI SAI SAT.

NO C

13 86 SPH2 DI SAI SAT.

NO C

15 87 SPH1 DI SAI SAT.

NO C

16 87 SPH1 DI SAI SAT.

NO C

10 89 SPH1 DI SAI SAT.

NO C

14 89 SPH1 DI MAI SAT.

NO C

21 89 SPH1 DI MAI SAT.

NO C

10 90 SPH1 DI SAI SAT.

NO C

10 91 SPH1 DI SAI SAT.

NO C

13 91 SPH1 DI SAI SAT.

NO C

17 91 SPH1 DI SAI SAT.

No C

7 92 SPH2 DI SAI SAT.

NO C

10 92 SPH1 DI SAI SAT.

NO C

15 64 AVB2

< 20 NO C

8 34 SPC1

< 20 NO C

7 51 SPC2

< 20 NO C

18 53 SPC2

< 20 No C

4 86 SPC2

< 20 No C

20 32 SPC5

< 20 NO C

8 68 SPC5

< 20 NO C

5 69 SPC5

< 20 No C

4 78 SPC5

< 20 NO C

4 78 SPC6

< 20 10 C

9 18 SPC6

< 20 NO C

7 12 SPC7

< 20 NO C

41 47 SPC7

< 20 NO C

4 69 SPC7

< 20 NO C

16 81 SPC7

< 20 NO C

10 88 SPC7

< 20 NO C

7 1

SPH1

< 20 NO C

12 38 SPH1

< 20 NO C

19 83 SPH1

< 20 NO C

11 89 SPH1

< 20 NO C

5 72 SPH3

< 20 NO C

14 34 SPH5

< 20 No C

13 64 SPH5

< 20 NO C

14 68 SPH5

< 20 NO C

13 69 SPHS

< 20 No l

C 18 69 SPHS

< 20 NO C

2 74 SPH5

< 20 No i

C 8

76 SPH5

< 20 NO C

24 85 CPHS

< 20 to C

24 85 SrH6

< 20 NO Page 8 of 10

s a

y.

'IRBLE I DISTANCE NML REFERENCE FIOt

'IYlICKNESS S/G RON COL POINT REFERENCE PENE11tATICN RPC VOLTAGE PLUGGED C

25 85 SPH5

< 20 NO C

12 2

SPH6

< 20 NO C

10 68 SPH6

< 20 NO C

15 69 SPH6

< 20 NO C

15 70 SPH6

< 20 NO C

27 77 SPH6

< 20 NO C

10 80 SPH6

< 20 NO C

28 35 SPH7

< 20 NO C

19 69 SPH7

< 20 NO C

12 67 TSC 1.0

< 20 NO C

27 11 TSH 42.9

< 20 NO C

30 13 TSH 16.5

< 20 to C

8 23 TSH 1.0

< 20 NO C

15 25 TSH 1.2

< 20 NO C

27 26 TSH 32.2

< 20 NO C

25 27 TSH 29.2

< 20 NO C

30 31 TSH 3.2

< 20 NO C

16 39 TSH 2.4

< 20 NO C

18 39 TSH 0.8

< 20 to C

11 3

TEH 5.1 68%

NO (F*)

C 29 12 TEH 13.3 50%

10 (F*)

C 14 15 TEH 15.4 62%

NO (F*)

C 2

20 TEH 15.8 70%

NO (F*)

C 25 21 TEH 13.7 50%

NO (F*)

C 23 24 TEH 2.1 78%

?O (F*)

C 4

26 TEH 11.1 56%

NO (F*)

C 9

29 TEH 17.4 82%

NO (F*)

C 17 30 TEH 18.6 89%

NO (F*)

C 28 32 TEH 10.6 59%

10 (F*)

C 25 35 TEH 14.2 73%

FC (F*)

C 14 38 TEH 5.7 50%

NO (F*)

C 11 39 TEH 1.9 97%

NO (F*)

C 15 41 TEH 16.1 84%

NO (F*)

C 25 41 TEH 12.6 58%

10 (F*)

C 7

43 TEH 2.7 82%

NO (F*)

l l

C 6

51 TEH 18.3 68%

to (F*)

l C

8 52 TEH 10.2 96%

to (F*)

C 11 54 TEH 2.5 92%

NO (F*)

l C

3 58 TEH 12.9 76%

NO (F*)

I C

9 58 TEH 3.2 98%

NO (F*)

(

C 11 58 TEH 16.2 98%

NO (F*)

l C

9 39 TEH 14.2 96%

NO (F*)

l C

10 60 TEH 9.7 98%

NO (F*)

C 10 60 TEH 12.5 84%

NO (F*)

C 10 60 TEH 18.4 95%

NO (F*)

C 10 61 TEH 5.9 93%

NO (F*)

C 10 61 TEH 16.3 84%

NO (F*)

C 8

62 TEH 17.1 75%

to (F*)

C 8

62 TEH 12.0 96%

to (F*)

C 9

62 TEH 6.8 96%

NO (F*)

l C

10 62 TEH 9.5 72%

to (F*)

l C

11 62 TEH 17.0 80%

to (F*)

Page 9 of 10 l

l l

a

'IRBLE I DISTANCE imLL REFERENCE FROM

'IMICKNESS Sg HOW (DL POINT REFERENCE PENEIRATI(N RPC VOLTAGE PLUGGED C

11 63 TEH 18.9 78%

NO (F*)

C 9

64 TEH 10.5 92%

NO (F*)

C 9

64 TEH 14.4 86%

NO (F*)

C 9

64 TEH 17.3 90%

NO (F*)

C 10 65 TEH 16.0 85%

NO (F*)

C 12 65 TEH 13.1 96%

NO (F*)

C 13 65 TEH 13.2 97%

NO (F*)

C 8

67 TEH 10.7 89%

NO (F*)

C 9

67 TEH 7.6 99%

NO (F*)

C 7

68 TEH 18.2 82%

NO (F*)

C 8

68 TEH 11.6 96%

NO (F*)

C 18 68 TEH 18.1 53%

NO (F*)

C 11 69 TEH 11.3 97%

NO (F*)

C 8

70 TEH 10.6 97%

NO (F*)

C 7

71 TEH 16.4 78%

NO (F*)

C 12 71 TEH 7.8 50%

NO (F*)

C 12 71 TEH 12.2 50%

NO (F*)

C 8

72 TEH 14.2 53%

NO (F*)

C 11 72 TEH 3.1 97%

NO (F*)

C 11 72 TEH 15.9 75%

NO (F*)

C 11 73 TEH 9.2 68%

NO (F*)

C 12 73 TEH 12.9 68%

NO (F*)

C 13 73 TEH 13.2 57%

NO (F*)

C 8

74 TEH 19.0 96%

NO (F*)

C 11 74 TEH 7.5 81%

NO (F*)

C 11 74 TEH 18.0 98%

NO (F*)

C 11 74 TEH 16.6 85%

NO (F*)

C 13 74 TEH 9.1 96%

NO (F*)

C 9

75 TEH 14.2 85%

NO (F*)

C 11 75 TEH 15.8 99%

NO (F*)

C 10 76 TEH 9.4 95%

NO (F*)

I C

9 77 TEH 18.8 98%

NO (F*)

i C

12 77 TEH 12.1 71%

NO (F*)

l C

7 80 TEH 19.3 80%

NO (F*)

l C

12 84 TEH 19.1 73%

NO (F*)

l C

10 86 TEH 9.5 89%

NO (F*)

l l

    • Non-quantifiable indications were characterized with the RPC and preventively plugged where evidence of cracking great.er than 40% through-wall was found based on a voltage criterion.

CDP:csl-V4 Page 10 of 10