16 APR 1988 Docket No. 99990001 License No. General Licensee E.I. DuPont de Nemours and Company Imaging Systems Department ATTN: Jeffrey B. Sutton Radiation Safety Officer R.D. #1, Box 15 Towanda, Pennsylvania 18848-9784 Gentlemen:
Subject:
AUTHORIZATION FOR TEMPORARY CONTINUED USE OF 3M P0-210 STATIC ELIMINATION DEVICES In accordance with your facsimiles dated March 17 and 21, 1988 and as provided in Section III., Paragraph C. of Order Modifying General License dated February 18, 1988, you are hereby authorized to continue temporary use of 3M Po-210 static elimination devices now in your possession as described below:
3 M Model No.
No. of Devices Location of Use within Plant 210-24 11 Room 408A - Spreading Booth and Room 403 - Subbing Process 906 2
Room 408A - Spreading Booth and Room 403 - Subbing Process This authorization expires May 6,1988, and is contingent upon your performing (or having performed) the following:
1.
Leak tests of each 3M device at intervals not to exceed 30 days.
If leakage is detected, a report shall be made as required by 10 CFR 31.5(c)(5);
2.
Contamination surveys of areas surrounding the 3M device at intervals not to exceed 30 days.
If contamination in excess of 1000 dpm/100 square cm is detected, a report shall be filed as if leakage had been detected in excess of 0.005 microcuries; 3.
If compressed air is used with a 3M device, checks of compressed air lines to ensure absence of water, oil, or other foreign material at intervals not to exceed 30 days.
This authorization does not permit you to receive new or replacement static eliminators from 3M.
0 h
0FFICIAL RECORD COPY AUTH DUPONT - 0001.0.0 8804280145 880416 MIURN ORIGINAL TO RE01 QA999 ENVDUP s
99990001 DCD EGION I
~
f 16 APR 1988 E.I. DuPont de Nemours and Company 2
Imaging Systems Department If you have any questions, please contact Josephine Piccone at (215) 337-5169.
Sincerely, Y
f I
William T. Russell Regional Administrator cc:
M. Lamastra, NMSS/IMAB Minnesota Mining and Manufacturing Company ATTN: Mr. Robert G. Wissink 3M Center 220-2E-02 St. Paul, Minnesota 55101-1000 bec:
Region I Docket Room (w/ concurrences)
J. Allan, DRA F. Congel, DRSS J. White, DRSS J. Joyner, DRSS J. Piccone, DRSS t
]
i
)
RI:DRSS SS bl':DRSS RI:DRSS Pi coneftim/pj hGlenn k Congel oyner A an
.?1. f'.
f 4 3/88 4//f/88 4(Y/88 4/l'[/88