ML20151R749
| ML20151R749 | |
| Person / Time | |
|---|---|
| Site: | Fort Saint Vrain |
| Issue date: | 04/08/1988 |
| From: | Caldwell R, Everett R, Joseph Kelly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | |
| Shared Package | |
| ML20151R747 | List: |
| References | |
| 50-267-88-05, 50-267-88-5, NUDOCS 8804280079 | |
| Download: ML20151R749 (1) | |
See also: IR 05000267/1988005
Text
-
- -
_ _ __
l
,
.,
- -
.
.'
<
APPENDIX B
U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
NRC Inspection Report':
50-267/88-05
Operating-License:
OPR-34
Docket:
50-267
Licensee:
Public Service Company of Colorado (PSC)
2420 W. 26th Avenue, Suite 15c
.I
Denver, Colorado 80211
Facility Name:
Fort St. Vrain Nuclear Generating Station (FSV)
i
Inspection At:
FSV, Platteville, Colorado
\\
Inspection Conducted:
February 29 through March 4, 1988
Ob
DR b
Inspectors:
tu,U
s
J.( AU. KellyMenior Seg1Tr5ty Inspector
Date \\
Pity 1ical Security Section
/f
h b /N
'
-
.
E. ~A. CaldweTT ,' Secufity Inspector
Date
Physical Security Section
.
I
Approved:
[ M. hd
'//s/If
'
R. J. Everett, Chief, Physical Security Section
Date
Inspection Summary
Inspection Conducted February 29 through March 4, 1988 (Report 50-267/88-05)
Areas Inspected:
Routine, unannounced inspection of previously identified items
of concern; security pian and procedures; security organization; locks, keys,
and combinations; protected area
physical barriers; assessment aids; access
control
personnel; protected area - detection aids; and personnel training and
qualifications.
Results: Within the areas inspected, three violations were identified:
1.
Failure to maintain. adequate exterior lighting (paragraph 7).
2.
Failure to document suitability files (paragraph 11).
3.
Failure to maintain second pair of eyeglasses (paragraph 11).
One unresolved item is discussed in paragraph 3.
1
ENCLOSURE CONTAINS
SAFEGUARDS INFORMATION.
8804280079 880420
~
DR
ADOCK 0500
7
UPON SEPARATION THIS
PAGE IS DECONTROLLED.
,