Summary of 860124 Meeting W/Nuclear Packaging Inc & Elekta Institute in Silver Spring,Md Re Proposed Application for Model Elekta Tiger Package
ML20151R171
Person / Time
Site: 07109201
Issue date: 01/31/1986
From: Odegaarden R
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 8602050434
Download: ML20151R171 (2)


Text

,

}f-$2Ol R Eli.C,'

0 NBChiin 3 0'b8 FCTC:Pdt0 71-9201 JAN 311986 f tDiO9 A't Dif F0Ps :

The files FROM:

Richard 9. Odecaarden, FCTC, NPSS SI'3J ECT-SU?SARY OF "ECTING CP"CER'llM NtiCLEM PACrAGINC, Irt.

MODEL NO. ELEKTA TInro Attendees Nuclear Packaging EL EKTa. Ins t.

NRC R. T. Haelsig Fans von Celsing C. R. Chanpell Robert Johnson P.

H. Odega arden Steve Porter

n. T. iiuang Pave Sn<Meker C. E. ?%cDonald Introduction A nectino ms held at the reauest of Nuclear Packaginc, Inc. (NUPAC) at Silver Sprinn, Paryland, on January 24, 1906 to discuss a procosed application for the !!odel No. ELFrTS TIrEP package.

i Discussion The acceptability of gray cast iron as a shielding material has not been dernnstrated because of possible brittle fracture.

Physical testing of the cast iron was pronosed by ?!UPAC. Calculations would need to be perfon-ed to determine the areas of greatest stress concentratinns and nachine flaws in these locations. The sizing of the flaws for cast iron (4 1% ductility) needs to be established. The !PC staff agreed that crack initiation nay be ademnate acceptance criteria considering that the cast iron serves as shielding rather than containnent.

However, this would depend upon further evaluation of the potential problems associated with the very low ductility of the cast iron.

Subsequent units fabricated would have to be as goed or better than the tested unit. Pecause of the uncertainties involved in denonstrating the adequacy of cast iron, the NPC staff succested alternate designs he considered usinq raterials with greater fracture resistance.

8602050434 960131 PDR ADOCK 07109201 C

PDR P

.v--.*

j l

l o..,>

.L 1

une rom na oc am sacu o:o OFFICIAL RECORD COPY

l The Files Initial NRC review of an irradiator constructed of cast iron would require fron 3 to G nonths.

gtelS$

~

Lt.

"ichard if, Adegaarden, Proiect l'anager Transportation Certification Branch.

Division of Fuel Cycle and f'aterial Safety, WSS Distribution:

Docket File NRC PDR Mtg Attendees GBeveridge FCTC Mtg File Book NMSS R/F FCTC R/F 1

c F