r-Northern States Power Company 414 N(obet man Minneapons. Minnesota 55401 Telephone (612) 330 5500 August 5, 1988 10 CFR Part 50 Section 50.90 Director of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Attn: Document Control Desk Washington, D C 20555 PRAIRIE IS1AND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR 42 50-306 DPR 60 Supplemental Information for License Amendment Request Dated July 5,1988 Best Estimate LOCA Analysis The purpose of this letter is to supplement our July 5,1988 License Amend-ment Request submitted for the Prairie Island Nuclear Generating Plant.

Attached for your review is a revised Appendix K calculation required by the NRC Staff draft Safety Evaluation Report for the UPI Best Estimate Methodology Program.

This calculation differs from the calculation in Exhibit E of our July 5, 1988 License Amendment Request in that a return to nucleate boiling, after reaching the critical heat flux, is prohibited during blowdown.

An amendment application fee is not required by 10 CFR Part 170 since a fee was included with the July 5, 1988 submittal.

Please contact us if you have any questions related to this License Amend-ment Request.

),[ () bw/ww* s David Musolf Manager Nuclear Support Services c: Regional Administrator-III, NRC Sr Project Manager, NRC Sr Resident Inspector, NRC MPCA Attn: J W Ferman j

G Charnoff

Attachment:

DEMONSTRATION OF THE CONFORMANCE OF PRAIRIE ISLAND UNITS 1 AND 2 TO APPENDIX K AND 10CFR50.46 FOR 1ARGE BREAK LOCAS 88o8110072 esosos DR i

g p

ADOCK 050002s2 PDC

{