ML20151P111

From kanterella
Jump to navigation Jump to search
Notification of 880811 Meeting W/Util in Rockville,Md to Discuss TMI Action Plan Item III.D.3.4, Control Room Habitability Requirements & Potential Mods to Control Room Emergency Ventilation Sys
ML20151P111
Person / Time
Site: Browns Ferry  
Issue date: 08/03/1988
From: Gears G
NRC OFFICE OF SPECIAL PROJECTS
To: Black S
NRC OFFICE OF SPECIAL PROJECTS
References
TASK-3.D.3.4, TASK-TM NUDOCS 8808090190
Download: ML20151P111 (4)


Text

.._

SQ ClQ

[*

  • o UNITED STATES 8^

o,%

NUCLEAR REGULATORY COMMISSION h

WASHINGTON, D. C. 20555 k....#

AtJn 0 31988

+

Docket Nos. 50-259/260/296 1

MEMORANDUM FOR:

Suzanne Black, Assistant Director for Projects TVA Projects Division Office of Special Projects FROM:

Gerald E. Gears, Project Manager TVA Projects Division Office of Special Projects

SUBJECT:

FORTHCOMING MEETING WITH TENNESSEE VALLEY AUTHORITY ON BROWNS FERRY NUCLEAR PLANT, UNIT 2 Date & Time:

Thursday, August 11, 1988 11:00 a.m. - 2:00 p.m.

Location:

One White Flint North 11555 Rockville Pike Rockville, Maryland 20852 Room 4-B-13 i

Purpose:

To discuss TMI Action Plan Item III.D.3.4, "Control Room Habitability Requirements" and Potential Modifications To the Control Room Emergency Ventilation System CREVS.

Participants *:

NRC TVA G. Gears E Carier, et al R. Pierson I. Spickler f

ww

/ Gerald E. Gears, Project Manager TVA Projects Division Office of Special Projects cc: See next page

  • Meetings betwe3n NRC technical staff and applicants for licenses are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meetings and Statement of NRC Staff Policy," 43 Federal Register 28058, 6/28/78.00cket Nos. 50-260 mamn magr n

P h

~

l io 1

Browns Ferry Nuclear Plant Units 1, 2, and 3 cc:

General Counsel Regional Administrator, Region II Tennessee Valley Authority U.S. Nuclear Regulatory Commission 400 West Summit Hill Drive 101 Marietta Street, N.W.

E11 B33 Atlanta, Georgia 30323 Knoxville, Tennessee 37902

.asident Inspector / Browns Ferry NP Mr. R. L. Gridley U.S. Nuclear Regulatory Commission Tennessee Valley Authority Route 12, Box 637 SN 157B Lookout Place Athens, Alabama 35611 Chattanooga, Tennessee 37402-2801 Dr. Heary Myers, Science Advisor Mr. H. P. Pomrehn Committae on Interior Tennessee Valley Authority and Insular Affairs Browns Ferry Nuclear Plant U.S. House of Representatives P.O. Box 2000 Washington, D.C.

20515 Decatur, Alabama 35602 Mr. S. A. White Mr. M. J. May Senior Vice President, Nuclear Power Tennessee Valley Authority Tennessee Valley Authority Browns Ferry Nuclear Plant 6N 38A Lookout Place P.O. Box 2000 1101 Market Street Decatur, Alabama 35602 Chattanooga, Tennessee 37402-2801 Mr. D. L. Williams Tennessee Valley Authority 400 West Summit Hill Drive kl0 885-Knoxville, Tennessee 37902 Chairman, Limestone County Commission P.O. Box 188 Athens, Alabama 35611 Claude Earl Fox, M.D.

State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36130 l

1 l

l

-)

August 3, 1988 Docket Nos. 50-259/260/296 MEMORANDUM FOR:

Suzanne Black, Assistant Director for Projects TVA Projects Division Office of Special Projects FROM:

Gerald E. Gears, Project Manager TVA Projects Division Office of Special Projects

SUBJECT:

FORTHCOMING MEETING WITH TENNESSEE VALLEY AUTHORITY ON BROWNS FERRY NUCLEAR PLANT, UNIT 2 Date & Time:

Thursday, August 11, 1988 11:00 a.m. - 2:00 p.m.

Location:

One White Flint North 11555 Rockville Pike Rockville, Maryland 20852 Room 4-B-13

Purpose:

To discuss TMI Action Plan item 111.D.3.4, "Control Room Habitability Requirements" and Potential Modifications To the control Room Emergency Ventilation System CREVS.

Participants *:

NRC TVA G. Gears PTCarier, et al R. Pierson I. Spickler Original Signed by David H. Moran for Gerald E. Gears, Project Manager TVA Projects Division Office of Special Projects cc: See next page

  • Meetings between NRC technical staff and applicants for licenses are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meetings and Statement of NRC Staff Policy." 43 Federal Register 28058, 6/28/78. Docket Nos. 50-260 Distribution Docket File NRC PDR Local PDR

'i Those on Attached List l

4 OSP:TVA/L A A/PM

.i

/P 1

E Crs:as

,ack PSims 8/3/8

/88 8

/88 L

_g.

r-1, DISTRIBUTION FOR MEETING NOTICE DATE0:

August 3, 1988 Facility:

Browns Ferry Nuclear Plant, Units 1, 2 and 3 Distribution

, Docket 6 File" NRC PDR.

Local PDR Projects Reading J. Partlow S. Richardson S. Black B. D. Liaw B. Hayes 3-E-4 F. McCoy RII F. Miraglia 12-G-16 E. Jordan MNBB-3302 W. S. Little RII M. Sims B. Zalcman E. Goodwin G. Gears D. Moran J. Kelly W. Lanning 11-E-22 J. Rutber 15-B-18 ACRS (10)g GPA/FA 2-G-5 GPA/CA(5) 16-G-19 I. Spickler R. Pierson J. Scarborough 16-H-3 P. Gwynn 16-H-3 C. Ader 16-H-3 T. Elsasser 16-H-3 M. Callahan 16-G-19 BFN Rdg. file TVA-Rockville j

i

\\e

. -. -