ML20151P100

From kanterella
Jump to navigation Jump to search
Safety Evaluation Supporting Amend 105 to License DPR-28
ML20151P100
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 08/04/1988
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20151P020 List:
References
NUDOCS 8808090183
Download: ML20151P100 (2)


Text

_

ps uog'o,,

/

IJNITED STATES I

NUCLEAR REGULATORY COMMISSION l'

n

(

WASHING TON, D. C. 20555

\\...../

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT N0.105 TO FACILITY OPERATING LICENSE N0. DPR-28 VERMONT YANKEE NUCLEAR POWER C0F'0 RATION VERMONT YANKEE NUCLEAR POWER STATION DOCKET N0. 50-271

1.0 INTRODUCTION

By letter dated December 9,1987 (W. F. Murphy, VYNPC, to T. Murley, USNRC, FVY 87-117) the Vermont Yankee Nuclear Power Corporation (the licensee) proposed changes to t.ppendix A of the operating license for the Vermont Yankee Nuclear Power Station dealing with the addition of equipment to the Automatic Depressurization System (ADS) and associated Technical Specifications. The modifications were described and committed to by the licensee in a VYNPC letter dated October 31, 1986. Specifically, the changes included identification of the additional instrumentation in the TS Table 3.2.1 (Emergency Core Cooling System Actuation Instrumentation). The staff has reviewed the submittal and has prepared the following evaluation.

2.0 EVALUATION 2.1 Conformance to Requirements of NUREG-0737, Item II.K.3.18 The revised Technical Specification changes reflect the addition of a oypass timer and a manual inhibit switch to the ADS / low pressure ECCS pump logic. The modifications were made in response to NUREG-0737, Item II.K.3.18 "ADS Logic Modification" and were identified as one of the approved options in the NRC evaluation of the BWR Owners' Group generic response to the subject NUREG-0737 item.

The staff safety evaluation was provided to the licensee by NRC letter dated June 3, 1983.

The staff safety evaluation stated that the time delay associated with the manual inhibit switch must be justified by analysis and the facility Technical Specifications must be modified to require testing of the timer. The licensee's submittal included discussion of both of these requirements.

The bypass timer setting of eight minutes selected by the licensee is based on avoidance of excessive fuel cladding heatup predicted by analyses using 10 CFR Part 50, Appendix K, Loss of Coolant Accident evaluation models and a demonstration that adequate core cooling is assured for limiting isolation events when the ADS blowdown is delayed 10 minutes after the reactor pressure vessel water level decreases to a low-low level setpoint for a sustained period. The eight minute byptss timer delay is the minimum time interval assumed in generic analyses supporting the proposed modification and has been found acceptable on other applications and is acceptable for Vermont Yankee.

8808090183 6:80804

{DR ADOCK 05000271 PDC

' The staff safety evaluation transmitted to the licensee on June 3, 1983 included a requiremi.it for a surveillance test of the bypass timer.

The

'cosed TS revision addresses this requirement and is acceptable.

2.2 Technical Specification Changes The Vermont Yankee Technical Specification changes resulting from the accepted proposal are as follows:

1)

Table 3.2.1, page 39:

The Table identifying Emergency Core Cooling Actuation Instrumentation has been revised to add the bypass timer data associated with the ADS inhibit switches.

2)

Table 4.2.1, page 53 and Table 4.2 NOTES, page 61: The Tables identifying the testing and surveillance requirements for the Automatic Depressurization System trip system logic have been revised to include new requirements associated with the approved modifications.

3)

BASFC Sections 3.2/4.2, pages 65 and 67:

The BASES sections associated with protective instrumentation are amended to include a discussion of the approved modifications.

The replacement pages identified in the licensee's request are consistent with the supporting analysis and are therefore acceptable es proposed.

The staff has reviewed the basis materfal provided by the licensee for the proposed TS changes to accommodate the ADS modifications to Vermont Yankee Nuclear Power Plant in response to NUREG-0737, Item II.K.3.18 "ADS Logic Modification." Based on the results of our review discussed in Section 2.0 of this SER, we conclude that the proposed Technical Specification changes are censistent with the design changes and are acceptable.

3.0 ENVIRONMENTAL CONSIDERATION

Pursuant to 10 CFR 51.32, an environmental assessment related to this amendment has been published (53 FR 29402

) in the Federal Register on Au The Commicsion has determined that the issuance of this amendment b a, 1988.

not have a signifkant effect on the quality of the human environment.

4.0 CONCLUSION

We have concluded, based on the considerations discussed above, that (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, and (2) such activities will be conducted in compliance with the Commission's regulations, and the issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public.

Principal Ccatributor:

M. McCoy Dated: August 4, 1988 m